Loading...
HomeMy WebLinkAboutEngineered Plans - 201998 - EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE o N—W—EXISTING WATER SERVICE 9EXISTING GAS SERVICE dH. b6L— OVERHEAD WIRES 0CUSTEST PIT Awl BENCHMARK old Cedor ULEGENDGreosome Rd PP _ Pa Whites Path LOCUS MAP NOT TO SCALE S 16'30'30" W S 16'30'30" W• 41.33' 67.69' `---- -- 10G MAP ID: 118-035 LOT 50 30,000 ±S.F. __.. 100 06 00 0 x 106.75 o Z and . 107.93 U O cJ. O 10935+ 310.37 �9 CO a o to + + TP -2 p 110.79.. 9•S,l�'�'L• Q u) 110.82 f {"'P /ENT STAKE + 1°5.15 N FND. n O I_# /1 EXISTING CESSPOOL tp; 109.3 11142' (PER RECORD AS -BUILT) 7 TO BE PUMPED, FILLED oeo v�%L f EXISTING CESSPOOL (PER RECORD AS—BUILT) W/SAND & ABANDONED 111.24 + + OR REMOVED. 11.31 ey Il 105.14 TO BE PUMPED, FILLED W/SAND & ABANDONED O•.` -ii )i �. OR REMOVED. + PROPOSED SEPTIC TANK 110.42 108.98.. 25' p 10904x. DECK C6.35 a 59740 PROPOSED SEWER CONNECTION 6'. EXISTING INV.=106.38 109.68 + 109.11 x EXISTING EXISTING CESSPOOL 04.66 '' +'0973109.74 HOUSE(J61) (PER RECORD AS—BUILT) • T.O.F.=1f0.Ot'",. iozsz TP -.1 TO BE PUMPEDD,,FILLED W�SAND &ABANDONED Permit valid for REPAIR t7F SEIYt11C S%``I 1 hONL102 PORCH" • OR REMOVED. due and L.lual �Ctatl c. va 140 10 14 102+51 64.1 9.47 GARAGE foi><,. ABUTTER SHALL BE NOTIFIED AND Boarb, Board of iteaaPth revfiew malt :ap.prrtsv at 1� eoyuttrl it rme los 9s + = 1.29 PERMISSION GRANTED TO F`/LL OR any tlature addit¢aanslr eewuv:atio... +�c�atiols to + 1079 u REMOVE. SCANa�,E t1i(6litdCS and%Oi 9tP 1DCCt1Yln tfwClift '•.a� 107 } ti� �• 102 4 &AC Id18i4Atb �tCRIfP ^ell ie9nVv: [Ot x 108.54 •"O . �. ,; 105 '°° ' BENCHMARK a �)' �, A,P0101.81 + 10578 +. 44 10G ¢ OUTSIDE CORNER CONCRETE APRON ry �pq tio'' EL. =102.33 hamn 9996 104.38 . n Ioo.es p x ,O E �. Date 109.00' •' 10022TAKE TACK FND. . __.. _ N 16'59'50"..E 99.83 inn 9975 edge Of pavement 99.63 99.63 99.66 COOT 2 3 2019 i CRANBERRY LANE EAL,H DEPT PLAN REFERENCES: 1) AS -BUILT PLOT PLAN, By S.E.E. Con., 35 Route 134, So. Dennis, MA 02660, Dated 8/21/2001 OF y,4S•S9e 2) PLAN BK 120 - PG 119 �( PROPOSED SEPTIC SYSTEM UPGRADE PLAN PETER T. Mc a 61 CRANBERRY LANE YARMOUTH PORT, MA CIVIL PLAN PLAN REVISION 10/24119 — ' No. 35109 1) CORRECTION TO PROFILE S.A.S. INVERT Prepared for: James Mangan, 28 Sturgis Lane, Barnstable, MA 02630 Rf 6IS1ERy�\\�F� Engineering by: SCALE DRAWN JOB. NO. E OWNER OF RECORD Engineering Works, Inc. 9 9 1"=30' P.T.M. 239-19 MANGAN, JAMES F It 28 STURGIS 12 West Crossfield Road, Forestdole, MA 02644 DATESHEET BARNST 8 ELMA 02640 (508) 477-5313 10/2/19 P.T.M. 1of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL 104.33 FOR A DISTANCE OF 15' AROUND THE SEPTIC TANK PROPOSED D -BOX PERIMETER OF THE SAS. INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER PROPOSED S.A.S. SET TO 6' OF GRADE INSTALL INSPECTION PORT OVER ONEH ROW( IN.) T.O.F.=110.0± CHVENT ARCOALF.G. F.G. EL.=107.7± F.G. EL. -106.2 TO 108.0± EL.=106.5± F.G. EL=106.5± CONNECT MAINTAIN 2S RADE MIN. OVER SAS. ALL ROWS L, = 11' L m 3-L INSPECTION - 9' PORT O Sm1% (MIN.) - O Sm1R (MIN.) O S=19, (MIN.) 4^SCH40 PVC 4"SCH40 PVC 45CH40 PVC 0" 14 TO INV. -106.1 I 48^ UQ= NVER I I LEVEL 3 ROWS OF 7 UNITS AT 6.25'/UNIT - 43.8' SLE INV. -104.27 PROPOSE D INV. -104.10 103.9 � INV.=105.90 INV. 103.92 3 OUTLETS SOIL ABSORPTION SYSTEM (PROFILEI INSTALL PROPOSED SEPTIC TANK INLET TEE ESTABLISH VEGETATIVE COVER CONNECT TO EXISTING SUITABLE SEWER PIPE CLEAN NATIVE OR BACKAT EXISITNG CLEANOUT, INV.=106.38± verif PERC SAILL T ERC SANDD TO TOP OF CHAMBERS NOTES: BREAKOUT -TOP C�.; .',:_:.':`. :..,-. ;'::r a'',c '• .....:.y". 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE TOP ELkV.-1Q4.3z INVERTS, PRIOR TO INSTALLATION. INV U3 9 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND BOTTOM ELEV.=103.00 TRUE TO GRADE ONON A MECHANICALLY COMPACTED 5' MIN. SEPARATION 283 6 6� STABLE BASE OR OR SIX INCH AGGREGATE BASE, AS TO GROUNDWATER SPECIFIED IN 310 CMR 15.221(2). 4' (MIN.) OF NATURALLY EFFECTIVE WIDTH -9.5' 3) INSTALL INLET & OUTLET TEES AS REQUIRED. OCCURRING PERVIOUS SOILS SUITABLE SOILS 4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE NO G.W., EL -95.0 r AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. USE 3 ROWS OF 7 -HIGH CAPACITY H-20 INFILTRATOR UNITS 5) THE OWNER IS RESPONSIBLE TO HAVE THE EFFLUENT WITH 6" SEPARATION BETWEEN EACH ROW & NO STONE FILTER CLEANED ANNUALLY. TWICE PER YEAR IS TYPICAL SECTION RECOMMENDED. SEPTIC SYSTEM PROFILE SOIL LOG GENERAL NOTES: DATE: AUGUST 21, 2019 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL SOIL EVALUATOR: PETER ENT PE(SE/1542) BOARD OF HEALTH AND THE DESIGN ENGINEER. H WITNESS: PHIL RENAUD HEALTHAGENT 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS THE CODE, TITLE V, AND ANY APPLICABLE TP -1 ELEv. TP -2 OF STATE ENVIRONMENTAL LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW: ELEv. DEPTH DEPTH 0' 0" 310 CMR 15.405(1)(b): 102.0 A 107.0 A 1) A 2' variance to the 3' maximum cover requirement. for up LOAMY SAND LOAMY SAND 10YR 4/2 10YR 4/2 to 5' of cover. S.A.S. shall be vented and H-20 Rated. 101.3 8" 100.2 6" 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR B B LOAMY SAND LOAMY SAND LOAM TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 10YR 10YR 5/6 DESIGN ENGINEER. 99,0 36 - " 104.5 30" 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING C1 C MED. SAND FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN PERC ENGINEER BEFORE CONSTRUCTION CONTINUES. 97.5 2.5Y 6/6 54" 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. C2 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF F -M SAND 2.5Y 6/6 THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION, 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. SILT LOAM 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 2.5Y 5/3 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS 91.0 132" 95.0 144" AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE PERC RATE <2 MIN/IN. "C" HORIZON DIRECTED BY THE APPROVING AUTHORITIES. NO GROUNDWATER ENCOUNTERED 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND 000000 00 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. /00000000\ 0 000000000000 0 0 0 0 0 0 28"--I F- 28"---� Closed End Plate Open End Plate 1- q DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOMS? j ^ 76„ SOIL TEXTURAL CLASS: CLASS II �1 75" yl h-34" DESIGN PERCOLATION RATE: <5 MIN/IN 1'25 DAILY FLOW: 330 GPD Side View End View DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO HIGH CAPACITY INFILTRATORS, H-20 LOADING PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY INFILTRATOR CHAMBERS LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF N.T.S. DISTRIBUTION BOX: 1 INLET, 4 OUTLETS (MINIMUM) PROPOSED SEPTIC SYSTEM UPGRADE PLAN USE 3 ROWS OF 7. HIGH CAPACITY INFILTRATOR H-20 UNITS. WITH 61 CRANBERRY LANE YARMOUTH PORT, MA NO STONE. SPACED 6* BETWEEN ROWS, FOR A 9.5' x 43.8' BED SIDEWALL AREA: NOT APPLICABLE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF) Prepared for: James Mangan, 28 Sturgis Lane, Barnstable, MA 02630 Engineering by: SCALE DRAWN JOB. NO. (INFILTRATORS) 21 UNITS x 6.25 LF x 4.73 SF/LF = 620.81 SF Engineering Works, Inc. N.T.S. P.T.M. 239-19 DESIGN FLOW PROVIDED: 0.74 GPD/SF(620.81 SF) = 459.4 GPD DATE CHECKED SHEET NO. 12 West Crossfield Road, Forestdole, MA 02644 NOMINAL BED AREA: 9.5' x 43.8' = 416.1 SF (400 SF REO -D) (508) 477-5313 10/2/19 P.T.M. 2 Of 2