HomeMy WebLinkAboutAir-tightness Test Building Air-Tightness Test Form s Customer Information: Building&Test Conditions: Name: MJ Nardone Building & Remodeling Address: 299 White's Path City: South Yarmouth Date: 11/7/2019 State/Zip: MA/02664 Phone: (508)771-9927 Time: 300 P.M. Email: Mike@mjnardone.com Building Address: (if different from above) Street: 8A Syritha's Way Floor Area (ft2): 1700 s.f. city/state: South Yarmouth, MA Comments: Permit#: 003163 Issued: 12/192018 Standard Level Accuracy Mechanical Ventilation: Aprilaire Ventilator Model 8142 45 CFM = Minimum Continuous Flow Rate* 95 CFM = 28.1 Min./Hour Run-Time* 120 CFM = 22.2 Min./Hour Run-Time* 160 CFM = 16.7 Min./Hour Run-Time* * - In accordance with ASHRAE62.2(2013) Test#1 Depress: V Press: Test#2 Depress: V Press: Pre-test Baseline Pressure: - 0.1 (Pa) Pre-test Baseline Pressure: - 0.2 (Pa) Bldg Press. Flow Ring Fan Press Flow Bldg Press. Flow Ring Fan Press Flow (Pa) Installed (Pa) (cfm) (Pa) Installed (Pa) (cfm) -50.2 B -50.3 691 -50.0 B -50.2 696 -50.7 B -50.8 693 -50.1 B -50.3 690 -50.0 B -50.1 694 -50.4 B -50.6 700 -50.8 B -50.9 690 -50.0 B -50.2 690 -50.4 B -50.5 699 -50.5 B -50.7 692 Post-test Baseline Pressure: -0•2 (Pa) Post-test Baseline Pressure: -0.2 (Pa) Fan Model/SN: Minn BD 130927 Fan Model/SN: Minn BD 130927 Results: Results: CFM50: 693.4 CFM50: 693.6 ACH50: 2.9 ACH50: 2.9 HERS Rater Name and Cert.#: Chris Picariello Cert.#: 6397177 (34,HERS Rater Signature and Date: 11/8/2019 Developed by Advanced Building Analysis,LLC