Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Bld-20-000393
ONE & TWO FAMILY ONLY- BUILDING PERMIT Town of Yarmouth Building Department or 1146 Route 28, South Yarmouth,MA 02664-4492 508-398-2231 ext. 1261 Fax 508-398-0836 1.:_n _� Massachusetts State Building Code,780 CMR '' Building Permit Application To Construct,Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only G Building Permit Number- �—(Z)D 293 Date App. l_ii ' Building Official(Print Name) —Signature Date SECTION 1:Sri'a INFORMATION 1.1 Property Address: 1.Assessors Map&Parcel Numbers6 10 Tall Pines Dr 1.la Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: na na na Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided na na na 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Matthew & Lindsay Pietro Yarmouth MA 02675 Name(Print) City,State,ZIP 10 Tall Pines Dr 508-776-7004 No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK (check all that apply) New Construction 0 Existing Building❑ Owner-Occupied ❑ Repairs(s) 0 Alteration(s) 0 Addition ❑ Demolition 0 Accessory Bldg.❑ Number of Units Other' Specify: SOLAR PANELS Brief Description of Proposed wore: Install solar electric panels on roof of existing house with any upgrades, when applicable, specified by design; to be interconnected with home electrical system 17 panels 5.335 kW SECTION 4:-ESTIMATED-CONS C�ONCOSTS. . Item Estimated Costs _ OfileialVse Only (Labor and Materials) ,, . 1.Building $ 2000 1. Building Pei mtFee $/-6 Indicate how fee is determined: 2.Electrical $ -0 Standard CityPfown Application Fee. 6000 p Total Project Costs(lt , x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List. 5.Mechanical (Fire $ Suppression) Total All Fees:$ 6.Total Project Cost: $ 8000 CheckNo. Check Amount: Cash Amount: O Paid in Ftill ❑Outstanding Balance Due: 0 - SECTION 5:.CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 101687 9/13/20 Dan Fonzi License Number Expiration Date Name of CSL Holder 390 Andover St List CSL Type(see below) No.and Street Type Description Wilmington MA 01887 U Unrestricted(Buildings up to 35,000 cu.ft.) R Restricted l&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding 781-816-7489 SF Solid Fuel Burning Appliances I Insulation Telephone Rmail address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 168572 3/7/2021 Tesla Energy/ Nathan Tissot HI;C2ftaµy lane or HIC_R strant Name HIC Registration Number Expiration Date IL rill 1-IancocK rcc] ntissot@tesla.com NtAntOn MA 02780 781-635-1030 Email address City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes 0 No 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Tesla Energy to act on my behalf,in all matters relative to work authorized by this building permit application. see attached 7/18/2019 Print Owner's Name(Electronic Signature) Date • SECTION 7b:OWNER OR AUTHORIZED AGENT DECLARATION By to ' my i .f f f low,I here= attest under the pains and penalties of perjury that all of the information con 'ed :f •:;on is : and accurate to the best of my knowledge and understanding. Nathan Tissot 7/18/2019 Print er S or • f. Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" TOWN OF YARMOUTH s.,q BUILDING DEPARTMENT o e y 1146 Route 28,South Yarmouth,MA 02664 3 6r� 508-398-2231 ext. 1261 Fax 508-398-0836 BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Chapter 40, Section 54 and 780 CMR, Chapter 1, Section 111.5, I hereby certify that the debris resulting from the proposed work/demolition to be conducted at 10 Tall Pines Dr Work Address 125 John Hancock Rd TAunton MA 02780 Is to be disposed of at the following location: Said disposal si be a licensed solid waste facility as defined by M.G.L. ha ter 11 S i 150A. 7/18/2019 Signature of Application Date Permit No. Construction Supervisor Commonwealth of Massachusetts Unrestricted-Buildings of any use group which contain + Division of Professional Lx:ensure less than 35.000 cubic feet(f01 cubic meters)of ondosed Board of Butkltng Regutattons and Standards space• `:onstracttOn Superv�so CS-101607 !Alums 00r1312020 0 DANIEL D FONZI ' 3110 A ROVER ., A. WN.MING'TON MA USW Failure to possess a currant edition of the Massachusetts State Building Code is canse for rovocaMon alibis license. For Information about this license Call(0.17)727.321111 or visit wwwmass.govMpl Commissioner Office of Consumer Affairs and Business Regulation 1000 Washington Street-Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card TESLA ENERGY OPERATIONS,INC. Re 38572 901 PAGE AVENUE Ex piration: 03/07l2021 FREMONT,CA 94538 Update Address and Return Card. Office of Consumer Affairs 6 Business Regulation ROM I>dPROVEIDNT CONTRACTOR Registration valid for individual use only TYIPR:Supplement Card before the exp M found return to: SIMMOMIRI Ellitilikla Office of C A and Business Regulation 168572 03/07/2021 1000 Was n S .S TESLA ENERGY OPERATIONS,INC. Bos 021 DANIEL FONZI �„c -... 901 PAGE AVENUE FREMONT,CA 94538 Undersecretary Not valid without signature Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card TESLA ENERGY OPERATIONS, INC. Re iration: 168572 Exxppiration: 03/07/2021 901 PAGE AVENUE FREMONT, CA 94538 Update Address and Return Card. Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE: Supplement Card before the expiration date. If found return to: Registration Expiration Office of Consumer Affairs and Business Regulation 168572 03/07/2021 1000 Washington Street-Suite 710 TESLA ENERGY OPERATIONS, INC. Boston, MA 02118 NATHAN TISSOT 6AiazvtaAr. /as9t 901 PAGE AVENUE FREMONT, CA 94538 Undersecretary Not valid without signature The Commonwealth of Massachusetts ,� Department of Industrial Accidents .=#lri Office of Investigations i = 0-= fI 600 Washington Street .=mot,,... _4 _. '= v Boston,MA 02111 .:._, www.mass.gov/dia Workers' Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): Tesla Energy Operations, Inc. Address: 901 Page Ave City/State/Zip: Fremont CA 94538 Phone#: Are you an employer?Check the appropriate box: Type of project(required): I.12 I am a employer with 13,000 4. ❑ 1 am a general contractor and I 6 ❑New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. El Demolition working for me in any capacity. employees and have workers' q 0 Building addition [No workers'comp. insurance comp.insurance.* required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 1 LEI Plumbing repairs or additions myself.[No workers'comp. right of exemption per MGL 12.0 Roof repairs insurance required.]' c. 152,§1(4),and we have no 13[ Other solar panels employees.[No workers' comp.insurance required.] •Any applicant that checks box N I must also fill out the section below showing their workers'compensation policy information. t tlomeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. l am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: American Zurich Insurance Company Policy#or Self-ins.Lic.#: WC 1074584-01 Expiration Date: 10/31/2019 Job Site Address: 10 Tall Pines Dr City/State/Zip: Yarmouth MA 02675 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against • violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DA• for/ rance coverage verification. I do hereby c rti ups, r I pa . ,nd penalties of perjury that the information provided above is true and correct. S ;t--e: Date: 7/18/2019 Phone#: 781-635-1030 1 Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: A ® DATE(MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 10/29/2018 • THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES NAME. 345 CALIFORNIA STREET,SUITE 1300 (A/CC.No.Ext):ONE FAX No): CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# CN104275261-STND-GAWUC-18- INSURER A:Zurich American Insurance Company 16535 INSURED INSURER B:American Zurich Insurance Company 40142 Tesla Energy Operations,Inc. 6800 Dumbarton Circle INSURER C:N/A N/A Fremont,CA 94555 INSURER D:N/A N/A INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-003569440-09 REVISION NUMBER: 4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY EFF POLICY EXP W M/ LIMITS LTR INSD VD POLICY NUMBER (MM/DD/YYYY) (MDD/YYYY) A X COMMERCIAL GENERAL LIABILITY GLO 1074588-01 10/31/2018 10/31/2019 EACH OCCURRENCE $ 2,500,000 CLAIMS-MADE X OCCUR Includes Host Liquor Liability DAMAGE TO RENTED PREMISES Ea occurrence) $ 2,500,000 X SIR:$750,000 MED EXP(Any one person) $ 5,000 X Tort Contrac Liab,No XCU EXCI PERSONAL&ADV INJURY $ 2,500,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 20,000,000 X POLICY PRO- JECT LOC PRODUCTS-COMP/OP AGG $ 6,000,000 X OTHER:$6M per Proiect/Loc Ace $ A AUTOMOBILE LIABILITY BAP 1074586-01 10/31/2018 10/31/2019 COMBINED SINGLE LIMIT $ 5,000,000 (Ea accident) X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per accident) $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ B WORKERS COMPENSATION WC 1074583-01(AOS) 10/31/2018 10/31/2019 x PER OTH- AND EMPLOYERS'LIABILITY B y/N WC 1074584-01(MA,WI) 10/31/2018 10/31/2019 STATUTE ER 1,000,000 ANYPROPRIETOR/PARTNER/EXECUTIVEE.L.EACH ACCIDENT $ A OFFICER/MEMBEREXCLUDED? N N/A EWS1074585-01(CA) 10/31/2018 10/31/2019 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under Limits apply excess of$750K SIR-CA E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS below DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Evidence of insurance CERTIFICATE HOLDER CANCELLATION Tesla Energy Operations,Inc. SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 6800 Dumbarton Circle THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Fremont,CA 94555 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Stephanie Guaiumi Jelktigs~X 6s.44iM~.• I ©1988-2016 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID:A6413C1C-BB17-400E-B621-C357268DFD18 SOLAR PURCHASE DISCLOSURE This disclosure is designed to help you understand the key terms of your purchase of a solar electric system ("System"). It is not a substitute for your purchase contract("Contract"), loan or any other documents associated with this transaction. Information presented below is subject to the terms of your Contract. Read all documents carefully so you fully understand the transaction. For more information on becoming a smart solar consumer please visit www.seia.org/consumers. Provider: Tesla, Inc. Installer: Tesla Energy Operations, Inc. Customer: Matthew Pietro Address: 3500 Deer Creek Road Address: 901 Page Avenue System Installation Address: Palo Alto, CA 94304 Fremont, CA 94538 10 Tall Pines Drive, Tel.: 888-518-3752 Tel.: 888-765-2489 Yarmouth, MA 02675 License#(if applicable): MA HIC State/County Contractor License#: Customer Mailing Address: 187310 MA HIC 168572/EL-1136MR 10 Tall Pines Drive, Email: customercare@tesla.com Email: customercare@tesla.com Yarmouth, MA 02675 Email: mpmasonry@gmail.com Contract Date: 6/4/2019 • Purchase Price Your purchase price: $15,261.75 List of any credits, incentives or rebates included in the above purchase price: $0.00 *NOTE: Not everyone is eligible for credits, incentives or rebates or can fully use them. Consult your tax professional or legal professional for further information. Payment Schedule Amount you owe Provider at Contract signing: $0.00 Amount you owe Provider at the commencement of installation: $0.00 Amount you owe Provider at the completion of installation: $0.00 Your financing partner will make the final payment to the Provider after installation for the following amount: $15,261.75 Financing Your system: WILL be financed NOTE: If your System is financed, carefully read any agreements and/or disclosure forms provided by your lender. This statement does not contain the terms of your financing agreement. If you have any questions about your financing arrangement, contact your finance provider and read all financing disclosures before signing a Contract. Installation Timing Approximate Start Date: 60-120 days from the date the Agreement is signed. Approximate Completion Date: 60-120 days from the date the Agreement is signed. Interconnection Approval PROVIDER is responsible for submitting a System interconnection application. Site & Design Assumptions for your Purchase The estimated size of your System is: 5.355 kW DC Estimated gross annual electricity production in kilowatt-hours(kWh)from your System in Year 1: 4,926 kWh 00 Solar Purchase Disclosure v.2017 Ft4. ❑ �. �• DocuSign Envelope ID:A6413C1C-BB17-400E-B621-C357268DFD18 • If you are financing your System through one of our financing partners,the timing and amount of your payments (and any applicable interest accrued)will be subject to the terms and conditions of your agreement with your financier. If your financier fails to make payment on your behalf, or your financing is terminated by you or your financier, you will remain obligated to make payment under the terms of this Agreement. 4,926 kWh ., Start Date 60-120 days from the date of this Agreement 60-120 days from the date of this Agreement Shined av Your signature Tesla, Inc. D047166022524F5... Name: Matthew Pietro Date:6/4/2019 Name:Sanjay Shah Title:Senior Vice President, Energy Operations You are entitled to a completely filled in copy of this Agreement,signed by both you and Tesla, before any work may be started. Energy Products Purchase&Home Improvement Agreement V7.0,2/15/2019 �. Tesla, Inc. 3601414 2 Version#76.2-1 PIL June 3,2019 _ - Of RE: CERTIFICATION LETTER I. Project/Job#JB-0263996-00 ZHU Project Address: Pietro Residence CNL 10 Tall Pines Dr 1 ODYarmouth,MA 02675 AHJ Yarmouth SC Office South Shore Design Criteria: Stru u .10* -Applicable Codes=MA Res.Code,9th Edition/IEBC,ASCE 7-10,and 2015 NDS -RiskCategory=II Henry Zhu DlgltallysignedbyHenryZhu Date 20/9.06.0313:21:4107'00' -Wind Speed=140 mph,Exposure Category C,Partially/Fully Enclosed Method -Ground Snow Load=30 psf -MP1:Roof DL=10.5 psf,Roof LUSL=24.6 psf(Non-PV),Roof LUSL=13.41 psf(PV) -MP3:Roof DL=10.5 psf,Roof LL/SL=24.99 psf(Non-PV),Roof LUSL=18.81 psf(PV) Note: Per IBC 1613.1; Seismic check is not required because Ss=0.148<0.4g and Seismic Design Category(SDC)=B<D To Whom It May Concern, Ajobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Tesla. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Tesla,Inc. T = S L n ,... Version#76.2-1 PIL a,„=... . s. .. u,..t uwe?,ea.r.. .!^tz,.a s�'..F ". . � ,,..0,+"' ,,,.�.ds;«"3u..�9F..wie�r; cm.,d„s . : „ "` _,,, •� : X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 64" 24" 39" NA Staggered 68 2% MP3 64" 24" 39" NA Staggered 61.8% 1 , :*`r•�!(,`,= , 7."> a ..-! .� «r.cru� -�W• '.,i,,..:' .. ....L , ..;�... ,. ., ` "F- - s;' ; 2�M -T ... " X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 48" 19" 66" NA Staggered 86.5% MP3 48" 20" 66" NA Staggered 78.4% _ ,,, j ,,K,x (De.roes) Member Evaluation Results MP1 38° Member Impact Check OK MP3 25° Member Impact Check OK Tesla,Inc. T = 5 L n b�:td/)9 RECEVED TOWN OF YARMOUTH JUf�i 1 U 20 19 • $) 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 _ Telephone(508)398-2231 Ext. 1292-Fax(508)398-0836 YAKNIUUTH ,`.,. v I G'S HIGHWAY OLD KING'S HIGHWAY HISTORIC DISTRICT COM -- . iUi9 APPLICATION FOR i :K CERTIFICATE OF APPROPRIATENESS kpplication is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended, for proposed work as described below&on plans, drawings, photographs, &other supplemental info accompanying this application. PLEASE SUBMIT 4 copies OF SPEC SHEET(S),ELEVATIONS,PHOTOS,&SUPPLEMENTAL INFORMATION. Check All Categories That Apply: Indicate type of Building: Commercial X Residential 1) Exterior Building Construction: New Building Addition _Alterations Reroof Garage Shed X Solar Panels Other: 2) Exterior Painting: Siding Shutters Doors _Trim Other: 3) Signs/Billboards: New Sign Change to Existing Sign 4) Miscellaneous Structures: Fence Wall Flagpole Pool Other: Please type or print legibly: Address of proposed work: 10 Tall Pines Dr Map/Lot# 117/16 owner(s): Matthew & Lindsay Pietro Phone#: 508-776-7004 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: 10 Tall Pines Dr Yarmouth MA 02675 Year built: 1985 Email: Preferred notification method: X Phone Email Agent/contractor: Nathan Tissot/Tesla Energy Phone#: Mailing Address: 125 John Hancock Rd Taunton MA 02780 Email: ntissot(C7tesla.com Preferred notification method: Phone X Email Description of Proposed Work: Install 17 solar panels on roof . • •se \I\\) Signed(Owner or agent): ' / _ Date: 6/10/2019 t ➢ Owner/contractor/agent is aware that a permit is required from the Building Department.(Check other departments,also.) > If application is approved,approval is subject to a 10-day appeal period required by the Act. > This certificate is good for one year from approval date or upon date of expiration of Building Permit,whichever date shall be later. > All new construction will be subject to inspection by OKH.OKH-approved plans MUST be available on-site for framing&final inspections. For Committee use only: / Approved Approved with Modifications Denied Rcvd Date: (a"Ib/9 Reason for Denial: Amount y r0� • Cash 2/8g)AV. ' Signed: ?� p� r l „ /� Rcvd by: 45 Days: ?r 49K 1 b �-( .1 k ' i)1 . , .1 ! , , , / l l Date Signed: / //20/9 1 APPLICATION#: ) 9 A 0 9 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERRED VIA A UL—LISTED AC ALTERNATING CURRENT POWER—CONDITIONING INVERTER. BLDG BUILDING 2. A NATIONALLY— RECOGNIZED TESTING CONC CONCRETE LABORATORY SHALL UST ALL EQUIPMENT IN DC DIRECT CURRENT COMPLIANCE WITH ART. 110.3. EGC EQUIPMENT GROUNDING CONDUCTOR 3. WHERE ALL TERMINALS OF THE DISCONNECTING (E) EXISTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, EMT ELECTRICAL METALLIC TUBING A SIGN WILL BE PROVIDED WARNING OF THE n. FSB FIRE SET—BACK HAZARDS PER ART. 690.17. ' GALV GALVANIZED 4. EACH UNGROUNDED CONDUCTOR OF THE r�. Fr6 . GEC GROUNDING ELECTRODE CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY • 4 i a 1 GND GROUND PHASE AND SYSTEM PER ART. 210.5. HDG HOT DIPPED GALVANIZED 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY I CURRENT WITH ART. 250.97, 250.92(B). Iil Imp CURRENT AT MAX POWER 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING t Isc SHORT CIRCUIT CURRENT OR ARE RUN IN METALLIC RACEWAYS OR kVA KILOVOLT AMPERE ENCLOSURES TO THE FIRST ACCESSIBLE DC %it{;i1)( } kW KILOWATT DISCONNECTING MEANS PER ART. 690.31(E). '• ,ILLJ f\ItvG'C ,l))f LBW LOAD BEARING WALL 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN s HJG} WAY { MIN MINIMUM REUEF AT ALL ENTRY INTO BOXES AS REQUIRED BY ----..„1 (N) NEW UL USTING. NEUT NEUTRAL 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL NTS NOT TO SCALE — LISTED LOCATION PROVIDED BY THE :i I. "? OC ON CENTER MANUFACTURER USING UL LISTED GROUNDING "°` - PL PROPERTY LINE HARDWARE. POI POINT OF INTERCONNECTION 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS. 'I,'I 0':" C 0 j t SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS I(}t".1 E r TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY SOL;I -1 f t V VOLT J f; ;y �^, VmpVoc VOLTAGEVOLTAGE ATAT MAXOPEN POWERCIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES Sheet 5 THREE LINE DIAGRAM Sheet 6 ELECTRICAL CALCULATIONS GEN 1. ALL WORK TO BE DONE TO THE 9TH EDITION Cutsheets Attached #168572OF THE MA STATE BUILDING CODE. ELEC 1136MR 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Yarmouth REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTIUTY; Eversource Energy— South Shore (NSTAR—Commonwealth Electric) cmcme m--THE INFMIAMM 1EPaN Ae"ME' JB-0263996 00 COWER GE9WVmt Mk CONTAINED SHALL NOT BE USEDFOR 1 E MATTHEW PIETRO 5.355 KW PV ARRAY Jose Eduardo Quezada Gomm T 5 I_ 1'7 BENEFIT OF ANYONE EXCEPT IE&A INC.,NOR MOWING SWIM10 TALL PINES DR SHALL IT BE DISCLOSED IN MOLE OR IN ZS Comp V4 w Flashing—Insert 0 KWH ENERGY STORAGE SYSTEM PART W OTHERS WI9sE THE RECIPIENTS Rom: YARMOUTH, MA 02675 °AGAWAM/N,EXCEPT IN CONNECRON MN THE SALE AND um or THE RESPECRYE (17) Hanwha Q—Cells #Q.Peak DUO BLK-G5/SC315 IES.A EOIAWQIT,MRNXlT RE MMTIEN PAGE NNE Set RD.: DAIS WRIER P°eNo"OF IESA Mc SOLAREDGE N SE5000H—USOOOSNC2 COVER SHEET 1 a 5/31/2019 I x ! PITCH:38 ARRAY PITCH:38 MP1 AZIMUTH:230 ARRAY AZIMUTH:230 _ MATERIAL:Comp Shingle STORY:2 Stories R .JP t OF { PITCH:25 ARRAY PITCH:25 Cty< MP3 AZIMUTH:50 ARRAY AZIMUTH:50 NO.52791 N» MATERIAL:Comp Shingle STORY:2 Stones t,K h-1. 9� Stru u.I Only Henry Zhu Digitally o 0 HenryZh° FEW r0 LEGEND Q (E)UTILITY METER &WARNING LABEL O 0 , 01 INVERTER W/INTEGRATED DC DISCO * Y e &WARNING LABELS AUTOMATIC RELAY O 0 I or I DC DISCONNECT& WARNING LABELS t ^ f�1 n'f Ci o�o MP2 a1. M 1 ! © AC DISCONNECT&WARNING LABELS 0 o 0 O • C O `I n..., r BQ DC JUNCTION/COMBINER BOX &LABELS 5C1. i-; - 0ENERGY STORAGE SYSTEM FOR STAND "f ALONE OPERATION O 0 0 0 0 0 0 0 DISTRIBUTION PANEL& LABELS O O O O O -_D- Iel LOAD CENTER &WARNING LABELS (E)DRIVEWAY , , AC \ O DEDICATED PV SYSTEM METER O O O O O O`, D 01 © I H„.. M Q RAPID SHUTDOWN O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR Fro use CONDUIT RUN ON INTERIOR 10 Tall Pines Dr — FENCE O HEAT PRODUCING RODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L_J SITE PLAN 4, Scale:1/8"=1' hIN 01' 8' 16' +t OM WNFUM,WE-THC INFMA11011FEM 'MI N°� JB-0263996 00 MAT °5 3 oJos CONTAINED SHALL NOT BE usm FOR THE MATTHEW PIETRO 5.355 KW PV ARRAY Jose Eduardo Ouezado Come: T = S L n BENEFIT OFEXCEPT TU A INC..NOR POSnMC m 10 TALL PINES DR 0 KWH ENERGY STORAGE SYSTEM SHALL IT BE orsuasm IN*OLE OR ZS Comp V4 w Flashing—Insert N ANYONE PANT To EII OTHERS OUTSIDE THE RECPYS YARMOUTH, MA 02675 CRCANIATEN,EXCEPT RI COEECTON PITH HOOP ES: THE SAE NC USE OF 114E RESPECmE (17)Hanwha O-Cells #O.Peak DUO BLK-G5/SC315 S EEr: REM w1e 1ESLA EQUIPMENT,%MOUT 11E rants IIIFNIu, PACE NNE: PERIN55ON OF TESL*INC _SOLAREDGE #SE5000H-US000SNC2 SITE PLAN 2 0 5/31/2019 0. • MIL f r ' { t ( 'IC /\ / NO.32791 01 • L (N) PV MODULE 1 \ Stru u.1 Only T r'� T'A l-',I v 1 -'Ll' t_, (E) MOUNTING PLANE (MP) n,} \ Aait.Specific INoslipt Maio 1..R Code A9LT,a Factor i ONp,,at.ma 51..a V-Md Ha Flu NOVA '°P° ' e, TYPICAL PV SIDE VIEW BPDOINO Calgary Ground Simm Load pa C 30 =r� T MP Wale Dwep,nNmaden NTSVP Nam MPI I/P3 - Roe.,, Cagy StiMpe Comp SIGmle ZS Cram Y4. E6 Comp Y4. FliatFq-Fao t Mr,Ipi,M Pitch 25 25 SLAW PT 113 pat lie pal - PV MODULE %MLL Non-PV 24.6 paf 210 pat 5/16"x1.5" BOLT WITH Standoff Spain Old Layout 5/16" FLAT WASHER VP Nam Iw MP] INSTALLATION ORDER Landeeopo A- s4• 64• ZEP LEVEUNG FOOT LOCATE RAFTER, MARK HOLE 6<orig.., °4. 24• ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT Iaan.aor.Y-Tbeang 09• »• HOLE. a"�p• - - `►� �i.L M r Pa ea x�SP"�a ar Of ZEP MOUNTING BLOCK ,- � ` ATTACH FLASHING INSERT TO �r'.a �,_,_ III - 2) MOUNTING BLOCK AND ATTACH P°A1°"'-0ritli' 1°' 20• ZEP FLASHING INSERT Paired Y-4pafag br 66" !.� !� TO RAFTER USING LAG SCREW. ���•••�• P.446 Y-corn.,. (E) COMP. SHINGLE r INJECT SEALANT INTO FLASHING "1w1 Stag*'^ SEagg..a (E)ROOF DECKING ! (3) INSERT PORT, WHICH SPREADS 20.0 Y o.e maximums that an a.a1.Mae,.to 6..Watan holing that.,beam a.IN.X r a.oa.Wad..and Y N dots raft.. SEALANT EVENLY OVER THE 5/16" DIA STAINLESS ROOF PENETRATION. STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES (2 1/2"EMBED, MIN) INSTALL LEVEUNG FOOT ON TOP (4) OF MOUNTING BLOCK & (E)RAFTER SECURELY FASTEN WITH BOLT. © STANDOFF Scale:1 1/2"=1' CC"naEAL-TIE INK'RMAla IM" Ke"A°R J B-0263996 00 amain: ° "°` °�°` NR _ CONTAINED SHALL NOT BE USED FOR THE MATTHEW PIETRO 5.355 KW PV ARRAY Jose Eduardo Quezada Game+ T = 5 L n BENEFIT OF ANYONE EXCEPT TESTA INC..NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN%HOLE OR IN ZS Comp V4 w Flashing—Insert 10 TALL PINES DR 0 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANunaa.EXCEPT IN CONNECTION NMI MOLESYARMOUTH, MA 02675 THE SALE AND USE OF THE RESPEcnw: (17) Hanwha Q—Cells #Q.Peak DUO BLK—G5/SC315 IE9d EQUIPMENT,MRNXTT DE 116TTEN NNat1E,, PAGE NNE WET: REM. DATE PERMISSION aF 1ESU Na SOLAREDGE #SE5000H—US000SNC2 UPLIFT CALCULATIONS 4 a 5/31/2019 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND(N)/8 GEC TO TWO(N)GROUND Panel Number.LC3040E11100 Inv 1: DC Ungrounded INV 1-(I)50.MEM/SE5000H-U50009IC2 -(17)HwaAa 0-CeIls I O.Peak DUO dux-G5/SC315 GEN�1 2 MODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number.46 555 634 Inverter,5000W.240V/208V,995/9e.0RH0 Wave e/UnIlee Dew and ZB,RGM,AFQ PV Module;315W,292.2PTC,40M I,Wod Frame,MC4,ZEP,I000V ELEC 1136 MR Underground Service Entrance INV 2 Voc: 40.29 VpmoK: 33.46 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS OENTIFIER (E)125A MAIN SERVICE PANEL (E)100A/2P MAIN CIRCUIT BREAKER Inverter 1 (E)WIRING CUTLER-HAMMER COOPER � 100A/2P Disconnect Meter Socket SOLAREDGE 1 / SE5000H-US000SNC2 (E)LOADS — n A �e /1 n u 1 N F�f_ _ n( m o, 30A/2P T ICI -EGc 'X. I MP1,MP3:1x17 �_ �Jrr�� A V 7 GEC yI W / m m -'�'�J,� i GN I-___EGC EGC .i a v V -1— N I 1' gg EGGGEC � --l V —T I I i i- GEC T_{ ... Y TO 120/240V SINGLE PHASE ,g4�'1' , UTILITY gRNCE � q§�' '- �:s� '+A��� �\• V,I 1 11 t \ '.ill 'r V- I �� t,\G 7 Voc' = MAX VOC AT MIN TEMP Poe.Bo.4plinIoni4 W.ZFP DC POI—(I)I0J AT t MP2�0 PV BACKFEED BREAKER A —(1)anzoo-HAMMER/oa211Be — 7 SauBma P4ao SMM4Ma Brad. 3M/2P,2 sp«a )CUTLER-HAMMER 3oA 24GVaa,Nan-Faeroe.NEMA 3R AC - -(2)c a RGV (1)anund/New1ERt D30A.G (I)AeG/B,sou Bw Copper S MB.CappR owns Ntld t:3aA,General Duty(DO) GnCI^ B I-(t)c000tp€RaTeizsati Sod.tt,III Type -(1) -(1)AW CAP;B-Une Meter Socket Aaaeeory (N)ARRAY GROUND PER 690.47(D).NOTE: PER EXCEPTION NO.2,ADDITIONAL "}"°'r.- ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF(E)ELECTRODE fT(1)AwE po,1HWTI-2.Elad --------_ ,` r^1- , ,. 1 LLL-,-(2)AWG po,PV Ste.e00V,avid voc• =500 VDC Isc=15 ADc O (I)AWG n0.7NMN-2,Rae 'I () U.' 'i' .'-' I O-(1)AWG go,Solid Bare Copper EEC Imp =350 VDC Imp=15.1 ADC L- (1(AWE/10.7HWN-2,WFBe NEUTRAL Vmp -240 VAC Imp-21 MC ,i t)?.. li (1(Cwait Kit 3/4'F/A7 -(I)AWG/9,TON-2,Dun EGC/GEC-(1(Conduit Kit 3/4'EMT TO'', SUtJ lF H ,,:,,,1 ,... iJ(i1 SCRPTICet OEM CMCENPAL-WE B 0MA5KN FTaEN a M-®a JB-0263996 00 1040 of caTARImu11 9 NOT BE USED FOII THE MATTHEW PIETRO 5.355 KW PV ARRAY Jose Eduardo Ouezada Gome: T = 5 L n BENEFIT OF AME E%CFPT MLA INC.,NOR MZS C SmSIEFI SHALL IT BE DISCLOSED IN THOLE vie N ZS Comp V4 w Flashing-Insert 10 TALL PINES DR 0 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE TIE RECIPIENTS YARMOUTH, MA 02675 EAa2A90N,EXCEPT N CORNECCOII VAN YOMinTH THE SALE MO USE OF 1HE RESPECTIVE (17) Hanwha 0-Cells #O.Peak DUO BLit-G5/SC315 IESLA EQUIPMENT,WIHOUT TIE MITTEN NVERIER: PAGE NAME: SWEET REW DATE PERMISSION OF 1ESLA INC. SOLAREDGE k SE5000H-US000SNC2 THREE LINE DIAGRAM 5 a 5/31/2019 • ) , ;_,,-'(IVi. _ i , _i.: J , i171 ! 'a,k.Y PV SYSTEM PRODUCTION METER INVERTER OM (E)MAIN ie DISTRIBUTION PANEL ANI II UTIUTYMETER °q L� PV SYSTEM -.-%) METER DISCONNECT .J •1. 48"min-75"max d-l r. ¢,.,r 36"min-60"max SC),' ® EQUIPMENT ELEVATION (EXTERIOR) EQUIPMENT ELEVATION (INTERIOR) �S ® mS CONROENIIAL-THE INFORHAQON HERON JOB NA ER: JB-0263996 00 CUSTENERAT DESCRP5M R9CN _ CONTAINED Slue NOT BE USED FOR THE MATTHEW PIETRO 5.355 KW PV ARRAY Jose Eduardo Quezada Goma; T • 5 L n DENERT OF ANYONE EXCEPT TULA INC..NCR MOUNTING SYSTEM SHALL IT DISCLOSED IN%ROLE OR IN ZS Comp V4 w Flashing—Insert 10 TALL PINES DR 0 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT OOOF PI THE UOF>H (17)MUM Honwha Q—Cells #Q.Peak DUO BLK—G5/SC315 YARMOUTH, MA 02675 TESEA EQUIPMENT.PITHOUT THE w8TTEN „ERB: PACE NMI: MEET: REV. DATE PERMISSION a TEsu INC. SOLAREDGE #SE5000H—US000SNC2 EQUIPMENT ELEVATION 5 a 5/31/2019 PROPOSED ARRAY M"0 .MAY r µ1:00) r. 79-0 42-0" -wool h 1 01 E1 SIDE/SOUTH ELEVATION Scale:1/4"=1.-0" PROPOSED ARRAY M.Aro.O MME AWAY if E1 SIDE/NORTH ELEVATION Scale:1/4"=1.-0" ccsicelm nEM ,XM.E "ER JB-0263996 00 WSTEMER DESORPTION MG* CONTAINED SHALL NOT RE USED FOR TIE MATTHEW PIETRO 5.355 KW PV ARRAY Jose Eduordo Ouezada Game; T = 5 L P1 BENEFIT a ANYONE EXCEPT TESLA MN1,NON ROAM STSEIE SHILL IT BE SSELOSED IN MOLE OR M ZS Comp V4 w Flashing—Insert 10 TALL PINES DR 0 KWH ENERGY STORAGE SYSTEM PART TO OTHERS ODTSIOE THE xECPIaTS YARMOUTH, MA 02675 QxOANZATION,EXCEPT M CONNECTION wTN EWES THE SALE AND USE OF THE xESPECTIw (17)Hanwha O—Cells #()Peak DUO BLK—G5/SC315 SEEM RR DAre TESEA EQUIPMENT,STHOIT TVE MPoTTEN WRIER PAGE NONE PTlaossaN OP lEStA Mc. SOLAREDGE l SE5000H—US000SNC2 ELEVATION 5 0 5/31/2019 s is i r ! Y,slsvi;iJ I t 3L D• it,�q r��IP�In��� fiGH�✓JAY s . •jj1 aJ rib � �� .fr . _ { • gypr k•1..,,,,A,."...--.ay ri . r "y. . . :11;\'',. r,'.,it '. I.s ii ' t eF .r 7 , SIAs d , ,•ate• .. _ _xo 4, t,a, yl� _ ' • ^- '" y,`?'mot ma's • • • . : Sr • • aQFXneC"AL-THE NE NN CRMAI NEREN '0B"El' J B-0263996 00 asnEEx °°°' _ _ caDrAxmsNALLNarBEusmFORnE MATTHEW PIETRO 5.355 KW PV ARRAY Jose Eduardo Ouezada Gome; 5 L n BENEFIT OF WOE EXCEPT IEAA INC,NOR MOUNTING MEN SHALL IT BE DISCLOSED IN MNXE OR IIZS Comp V4 w Flashing-Insert 10 TALL PINES DR 0 KWH ENERGY STORAGE SYSTEM PART TO CIDERS OUTSIDE THE RECIPENYS ORiANZAMOK EXCEPT INCONNmMN MNMa MIXER YARMOUTH, MA 02675 nE SALE AND USE OE 114E RESPEcn8E (17) Hanwha 0-Cells #O.Peok DUO BLK-G5/5C315 1ES A EQUIPMENT.MIHOUT DIEMPoTIEN iimi t PAGE NAME SHEET: REM. DAIS PERMISSION OF MESA RC. SOLAREDGE #SE5000H-US000SNC2 RENDERING 5 0 5/31/2019 • 9 Jr 1: ELECTRICAL CALCULATIONS string and 2 Combined Strings Module Type: Module Count: Icons=(Amps): Hanwha Q CELLS Q.PEAK DUO BLK-G5 3137 15 Branch Circuit Parallel MPPT 1 strings per Branch A strings per Branch B 17 modules per series string modules per series string String Branch A Branch B _ _ Conductor: Conductor: Conductor: Icont'1.25=(Amps) 15 18.75 30 deg C ampacity= 40 40 - - - PV Wire Size: AWG#10 AWG#10 Icom=(Amps) 15 15 Start ampacity 40 40 I Temperature Berate(%=F) 0.82 0.82 Conduit fill derate(%_#) 1 1 Derated ampacity 32.8 32.8 a - ! Icom'1.25=(Amps) 15 18.75 { '-+ ,+n. . Ampacity 40 40 `� -'r';.'/ Inverter Output RI Inverter Type: inverter Count: Total SolarEdge Technologies:SE5000H-US RGM [cant=(Amps): 21 'coot*1.25=(Amps) 26.25 OCP Size= 30 Conductor 3: AWG#10 THWN-2 ''---- Icom'1.25=(Amps) 26.25 r�F��'.-d 30 deg C ampacity= 40 a g`;y !cant=(Amps) 21 s �.+ A 9 7 7`-- ..„,.... . t ' ,y;,1;:) Start ampacity 40 r :.,j Temperature Berate(%=F) 0.91 0,19 Conduit fill iterate(%=#) 1 ri Derated ampacity a y%) 7 "� '�� i_ Icont'1.25=(Amps) 26.25 u r .' - '', \ Ampacity 35 \�n r.,\A l_G S'r\\��V'.---�✓~ 5C)u,t. i f v l H. MA nk-TE TDN 43V3N "44.3t JB-0263996 00 CUSXMOt OESCRPTIOt DE9aE caTµED SMALL NOT BE Usm FOR THE MATTHEW PIETRO 5.355 KW PV ARRAY Jose Eduardo Quezada Game; T = 5 L n I18EFIT OF ANITIE EXCEPT TESTA INC.,NOR IIeM111G srslEu sou IT BE DISCLOSEDIN TIME OR IN ZS Comp V4 w Flashing—insert 10 TALL PINES DR 0 KWH ENERGY STORAGE SYSTEM PART To OTHERS OUTSIDE THE RE7PETTS YARMOUTH, MA 02675 ORGANIZATION,EXCEPT M CORRECTOR W M MCO ES THE SALE NO USE OF THE RESPECTIVE (17) Hanwha 0—Cells #Q.Peak DUO BLK—G5/SC315 SIHFET: REV: OATe TESTA EQUIPMENT,MT/OUT THE MITTEN PAGE NNE PERMISSION OF ESLA INC. SOLAREDGE #SE5000H—US000SNC2 ELECTRICAL CALCULATIONS 6 a 5/31/2019 CAUTION . ; ,‘ . . L POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: • trilviou I ti -Address: 10 Tall Pines Dr • )1 '_%KING'S HIGHWAY INVERTER AND DC DISCONNECT UTILITY SERVICE h-w AC ` • '° DISCONNECT SOLAR PHOTOVOLTAIC ARRAY(S)I UU7H ( Ec• , f-t, MA PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE= 240V JB-0263996-00 eMeaAL NPo ON 1EIRMAn ' NNa 1 4et JB-0263996 00 CUSTOM CESCRPTICAt °°°` CONTAINED SHALL NOT BE USED FOR THE MATTHEW PIETRO 5.355 KW PV ARRAY Jose Eduardo Quezoda Gome; n BENEFIT OF ANYONE EXCEPT MLA INC,NOR IMMO S1S1E1k T 5 L SHALL IT BE DISCLOSED IN MOLE OR IN ZS Comp V4 w Flashing—Insert 10 TALL PINES DR 0 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE 1HE RECIPIENT'S a€WN nMD� c nF THE c wn+ I(17)DiE SALE Hanwho 0—Cells #Q.Peak DUO BLK—G5/SC315 YARMOUTH, MA 02675 1ESIA EQUIPMENT,WITHOUT DE two PACE NNE 94F0 REV. DAIS BREMPERMISSION OF IESU NC. SOLAREDGE #SE5000H—US000SNC2 SITE PLAN PLACARD 7 0 5/31/2019 N! �i 11�Fi Ir r�sEF:S•,c,,: Label Location: Label Location: Label Location: (C)(CB)(JB) WARNING (AC)(POI) WARNING (DC)(INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 CI E� 11'�`1'-E.K EIINAL NEC 690.17.E ` I NEC 690.35 F uEarrEnoucH.KIIA�I'AN<D �vr,u l r ��1�1c ( ) Label Location: TER1.11NA s oN GO`11 I INr AND n 1,:r .F:1 TO BE USED WHEN _J IAn I•:r,IAr CSC I NEPL,IZ ) uN 1er I,NI 1 >AN1, INVERTER IS PHOTOVOLTAIC DC (DC)(INV) .1FI1E I> CNr ,S1TON Na rN F '1�n UNGROUNDED DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: Hurr,wn lAll -''Trmr (INV) 1 r' r 1r'I r.. (DC)(INV) I Pro 1 I PAPIN Per Code: I' 1 l ",I�.N ' II= PerCode: ,Nn!ro :era CEC690.56(C) :','''.1 I' .,r: IIIII NEC 690.53 �Ir url .irr.E�e _" Label Location: ' WARNING (P01) Per Code: 1n:r-r.rar .II NEC 690.64.B.7 NaFr.nt�N Label Location: DE.NEE I III 1 E�:r.II WARNING ,I (DC)(INV) of- E ' Per Code: NEC 690.S C r ENur . r r. , .lrr, ( ) nrnl,°,u v :;uNOEr C oNnII.:TIIE 1=N NI \ . I Nc_,E,INrn,;,Nu.NFl 'I 1 n Label Location: F" CAUTION (D)(Pop u,1 ,.r:rre1 PerCode: NEC 690.64.B.4 Label Location: WARNING (DC)(CB) r1_ECn 1 E,l1 F 1 .Pr, Per DI.N n i :II r r n.1 NEC 690.17(4) • Label Location: • ..ti I Nv r ,.'r, LEE '44L I,.,.E._Iu r.1,°. F_LNLE..1.1-1, CAUTION (P01) IN 1HE.aP'_N I•.,I,,,N El,,, r'I ,J11' .,DHEE Per Code: e 11,r,-,'NH'nu E Is NEC 690.64.6.4 i It �,-.PI-:f f NI WHEN f II)I�1V<]I l�I V.;TEAI EXPD,. D 1.`.,uNE I.-;H Label Location: E:,1ul uvou A1C I' N DI (P01) Label Location: INTFP.C.ONINFIEIN,N per Code: PHOTOVOLTAIC AC (AC)(P01) �,' awr, n N Nr Ho •< (AC):AC Disconnect DISCONNECT Per Code: NEC 690.17.4;NEC 690.54 I l l n a _s 1 r�r w E s�r. (C):Conduit NEC 690.14.C.2 ., .II,DIE l_NE .III E (CB):Combiner Box r.1-,7 Nir I NI P;1rrn IN THE Off NNE,E nI ,N rEE I (D):Distribution Panel , ,n r N N�,�E ,n I l jucE (DC):DC Disconnect (IC):Interior Run Conduit Label Location: ua.F (INV):Inverter With Integrated DC Disconnect _ (AC)(P01) ME (LC):Load Center ,,.II II �1 N PerCode: . r 1 �I 11' (M):Utility Meter E NEC 690.54 ,1,' e (P01):Point of Interconnection Label Set r - N fiVlt.Alf r; i J!.D r`ING'5 HIG I f-PAAY IP El S0SolarCity Zep Solar Next-Level PV Mounting Technology ItSOl&&CIty I Zep Solar Next-Level PV Mounting Technology . ZS Comp Components for composition shingle roofs11111111111111111 IA � ,., ,�„� Mounting Block Array Skirt Interlock N• roes _ ,� '. zas. '� Part No.850.1633 Part No.850.1608 or 500-0113 Pail No.850.1388 or 850.1613 a.,r. .i - Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 1 t 12a1(A iJ 1- J 41Ih IP 1 . . . f .,.. . �` Flashing Insert Grip Ground Zep V2 Pert No.850-1628 Part No.850-1606 or 850-1421 Part No.850-1511 Listed to UL 2703 Lusted to UL 2703 Listed to UL 467 and UL 2703 OOwP4 „� 6 Des•c PViirqunting solution for composition shingle roofs W • Works with all Zep Compatible Modules 'an',, • Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class'A'Fire Rating when installed using nodules from any manufacturer certified as-Type 1°or-Type 2° Captured Washer Lag End Cap DC Wire Clip C)LIBTEs Part No.850-1631-001 Part No. PartNo.850.1509 Specifications 850-1631-002 (L)850.1586 or 850-1460 Listed to UL 1565 850-1631-003 (6)850-1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products am UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703 � ` ' • Engineered for spans up to 72'and cantilevers up to 24' ,�7 / • Zep wire management products listed to UL 1565 for wire positioning devices 1 sO Leveling Foot Part No.850-1397 zepsdar.00m zepsolar.com Listed to UL 2703 This document does nit Dea.any express warranty by Zep Solar or toil its proms or seniue.Zep Soler*sole warmly is tortured In We ores,product wanarxy for The document does not create mry°seroesvrmranty by Zep Solar or about its products or services.Zap Solar Sole warranty Is contained F the*gen prod twaranty for each product.The end-user documentation shipped well Zen Soler's products constitutes the sole specacesons referred to Fero product emrenty.The customers solely each product.The end user documentation stripped wife Zep Soler s products constitutes the sole specrrcanons referred to in the product warranty The crabmer is solely responsible for verifying the suitability of ZepSalar's products for each use.Specacaduns are subject to change wail*.notice.Rehm%end Apes:sepab.00m. responsible for verifying the sul ablay of Zepaolei s products for each use.Spececetlons are subject to change without notice.Patents and Appe:xepets.com. Document*800.1839-001 RN;0 Date lest exported:Aps29.201011:22 AM Document*800-183g-001 RevD Date last exported:April 20,201611.22AM )slI;' a A.1,-, 1 jU U Lei solar- • • Y AKMc,u_T H. I.1••I solar- d• SolarEdge Power Optimizer-Zep CompatibleTM I^C -I f�i ',f`�Al NI Module Add-On For North America P400-ZEP SolarEdge Power Optimizer- I P3OO-2EP(for 6Dtef PV modules)1 P4OO.ZEP(for72&9&cellmodltles)J INPUT __ Rated lnput DCP era 300.... 400 ........ W Zep CompattbleTM' Module Add On Cl_ Absolute Maxim Input Voltage)Voc at lowest 48 80 Vdc temperature) L For North America P300-ZEP,P400-ZEP MPPT Operating R ge 48 1 &BD Vdc Maximum Short Circuit Current(1st) 10 50.1 Adc O Maximum DC I p tC went 12.5 12.63 Adc /'V� Maximum Efficiency 99.5 .._.,„ % CCI.. Weighted Efficiency 98.8 % Overvoltage Category 11 W' "• >,%. OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _ Maximum Output Current 15 Ad' S M um Outp iV(cageage_,.. 60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) O Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE CL EMC FCC Part15 Gass B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II yessafety),UL1741 ROHS .. . .... t INSTALLATION SPECIFICATIONS 1 Maximum Allowed Sy[ Voltage _.. 1000 _ _ Vdc Dimensions including mounting bracket M/xLoff 128 x 196 x 275/5 x 771 x 108 128 x 196 x 35/5 x 771 x 1.37 mm/in �. ... .... ... 128x152 x35/ Dimensions excluding mounting bracket(W%L%H) 128 x 152 x 27.5/5 x597 x108 Sx 5.97x 1.37 min/in Weight( ding cables and mounting bracket) 720/1,6 840/19 I kg/Ib Input Connector MC4 Compatible Output Connector Double Insulated;MC4 Compatible Output Wee Length 0.95/30 1.2/39 m/ft Operating Temperature Range 40 H85/-40 H385 'C/'f Protection Rating IP68/NEMA 6P w. , Relative Humidity 1 0.100 1 %..... s PV SYSTEM DESIGN USING A SINGLE PHASE THREE PHASE THREE PHASE SINGLE PHASE x SOLAREDGE INVERTER,. HD-WAVE 208V 480V ri 5�+. N V 4 k '4 X'T 'y?P4-.,�yy".� R Minimum String Length(Power Optimizers) i 8 10 18 '} r. Y ' "sis G M, Y } V y 4 R rE§�,7' ,p, spy drf 3-i'� f a� Maximum String Length(Power Optimizers) 25 25 50 4 .2 �� k kr1 *tS �;. 5700(6000 with w 4 paY r 'emuy i'dz` yi g p__� # F Maximum Power per String 5250 6000 12750 W ' .`. .. 'N ^p d -G, _.-+ '.4.''+' f1401 et',eh 188*41611%.. SE7600H-US) ..... " !,,_,...�a�`� 1*t0,1,4,4�p� ' - '` osdg� ` Parallel Strings of Different Lengths or Yes �&yxr4 ~q��r.`t'^^o"'-^X ���,ss.p qy� .,. RtbWiii,f,th*Fit14 Bits L'. Y•�,at•c W YaallintrnanirMnrt space titillation 0 t.e .enwertnAleeterequennenterovNedffiniultrtrit bracket -Next geneMfon maintenance with module-level monitoring ,'•"• wince. m maa� M,n. -Up to 25%more eneigy -Module-level Voltage Shutdown for installer and firefighter ::. -Superior effluence(99.%) CE 0 USA-CANADA'GERMANY ITALY FRANCE LAMA CHINA L AUSTRALIA-.NETHERLANDS Ux ISRAEL ULRICH HUNG.BELGIUM ROMANIA BULGARIA L+L.m.U,e I Hkl.uY . Pa• jr,... 6,,,,,,,,... ... .. .. 1 o .../,1-; /....:LI 1 S , . s Single Phase Invertersifor,Npritp !!riapiou i h solaran' so„-,-,..,.. ,, . , i SE3000H-US/SE3800H-US/SE5000H-US/SE6015. 'gf..:` iii-1,SSI{.1 I G 1_1 v,..,,,, i Lu SE10000H-US/SE11400H-US 1.1 PA y I SolarEdge Single Phase Inverters F--- ---1---TSEEIOCOH-US SESSCOH-USISE5000H-USTSE6COOHTS-E10000H-UITS-111400H-US r OUTPUT CC Rated AC Power Output 3000 3383.:224°8°,V I 5000 I 6000 Il 7600 10000 11400 VA for North America U..1 Max.AC Power Output 3000 3900 @240V[ 6000 [ 7600 10000 11400 I VA 3300 @208V; 5°°° SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ > AC Output Voltage Min.-Nom.- Max.(183-208-229) / 1 i 1 - - - Vac SE7600H-US/SE10000H-US/SE11400H-US Z AC OutPut‘MIT*6*Min ''N "': Max.(211-240-264) AC Frequency(Nominal) / 1 / 59.3-60-60.5i* ./ .c ./ Vac Hz Maximt 2um08V Continuous Output 16 [ 24 [ - [ - - A Curren [ I Output Current 240V 12.5 16 i 21 [ 25 32 42 47.5 A GFDI Threshold 1 A . utikty monitoring,Islanding . ., . . e ....sir -40-.,„ Yes '' : .•, Thresholds , r'. . INPUT ' Maximum DC Power 4650 5900 7750 : 9300 11800 15500 [ 17670 [ W Transformer-less,Ungrounded Yes 1 .r•I,..; 480 Vdc Nominal DC Input Voltage 380 , 400 Vdc 7- • - [ 9 13.5 : - - - - Adc - : Maximum Input Current 240V 8.5 : 10.5 13.5 16.5 20 27 , 30.5 Adc •••• Max.Input Short Circuit Current 45 Adc .. Reverse-Polanty Protection Yes . . - 1° Ground-Fault Isolation Detection 600kn Sensitivity '[II II ,1": ..- Maximum Inverter Efficiency 99 I 99.2 % •.., ..V • I CEC Weighted Efficiency 99 % . , I ...-, NighttlmePOwerConsomptlon --I- I <2.5 W ADDITIONAL FEATURES _. • • .•!-, .i Supported Communication R5485,Ethernet,ZigBee(optional),Cellular(optional) . iwi------- interfaces Revenue Grade Data,ANSI C12.20 Optional,* ° .*.:,, I Rapid Shutdown-NEC 2014 and STANDARD COMPL/ANCE 2017 690.12 Automat<Rapid Shutdown upon AC Grid Disconnect , .I "(t II:,..'.:I,.;'.° Safety UL1741,UL1741 SA,UL169913,C5A C22.2,Canadian AFCI according to T.I.L.M-07 [,:..: - .,7,',.,,,,,, .. ,,,. re ,,,/1, Grid Connechon Standards IEEE1547,Rule 21,Rule 14(HI) INSTAUATION SPECIFICATIONS FCC Part 15 Class 0 '1,4'il'.4;j1Vir,,::::11.4,974,!'40A000:174V744,„'Ye:,'S AC Output Conduit Size/AWG I 3/4"minimum/20-4 AWG ii:Ar'r5I'Mge:4474P::;44TX.4I::Ii Range I I i!,;...,.4,-,:',;t,' .,,i!)..,..., _ittur :',..c. . . ,. --- . r ----. .- --,, - '-.- - .' DC Input Conduit Size/4 of Strings I 1 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/ 14-6 AWG 'I,ifg,T:,'IT' '-t+liret**): [,:ffi*...i...,..p,..,...t.t....r.r,-,-,.',,,-.-.,-,.-.-:-.--..,.,,,-...:,..,,-t,--'-- -..,,,tr...--.-....f.. . ,', /AWG Range , 21.3 x 14.6 [ 21 3 x 14.6 %I tfii,[[:.,i,,,,IP,:4045:II.:7,-[•%* I', I': '..T-I' I,..1.'l't II'H, : s"-TT** ' I[II 0*.fPt..';::,;?"'.'"I;',::;'+''' Dimensions with Safety Switch 17.7 x 14.6 x 6.8/450 x 370 x 174 : x7.7/540x [ x7.3/540 x I in/mrn ' :14! , ' ' 1.-I''I' - I'•[ It.I:i.41044,i =I'I',)*-II I*P4III71;11: 4444?''''''''II'r'''.',i4I4i'''''' (HxWxD) I 370 x 195 370 x 185 I .1'''‘,,,', r .,?',,,,,'W1.,,,,"', ,,,V41,, A , ), ,`,,,•,,ix..,14.,..0.P.,'Ar'''''',.' ' Weight with Safety Switch 22/10 11.4 I 26.2/11.9 ` ',.",,'' , <25 <50 [ dBA [;'''.[ ."ftal;/°4•tiit'6[ Oritilet•• .•I: ') „))..I[...`& II', :2 i,--.,..r.47'..:,`,.,..7.:„....-..... ,. , , ,,..',:, ,, Cooling Natural Convection Int.lt"4,' 911.U144r$,14)9."90,10, 1..'49,111#,,! ,*ird,rrt7r,,,,110."?:.-”r1,19:9 ,..,.„,...... -,.,.,,,... Protection Rating Opereong Temperature Range •13 to+140/-25 to.60*,(-407/-40.0 option). NEMA 3R(Inverter with Safety Switch) [ 'F/'C .., [ •Extremely small , "rok ' - --- • •.,High reliability without any electrolytic capacitors .,Built-in module-level monitoring . Iiiinilr'l jiff Outdoor and indoor installation wave ....Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) ..Simple configuration and commissioning with smartphone app and built in WI-Fi(SE10000H-US,SE11400H-US) a RoHS uno-ovuroaco moot op-t.-patton nooc•eros-ca nv-a ynoanptnv,a once n-mac on,pconr.en n-n-,cocos onto n-u'scorn oanonnn- www.solarodgo us ” • ,.. F 1,m._,. by lu QANTUN( Utz' f- �J 2049 MECHANIC LS C:R._Cr11L ...t.7. 'a' ery"w Fxmer 66 3 39.4 1 57 n(Intl drag framed (1685 mmu1000mmxdOmm) �e . • �J` ( �I 1 i H W.i t 44.51 bs120.2kg) ,.o-... 1\Il'IV V I ypre-s Tess Bass wit,.....,.....iraR Cover 0 l3tn 13.2 tutu)[hermall t Qa L+fi\x G'L HIGHWAY Rack Cover Composite film I»u,�'w� l,� HIGHWAY 7 V V/':1 frame Black anodized aluminum ® " Call 6 x 20 monocrystalline 0 ANTUM solar half cells Immtion box 2 76 3 35 n x 1 97 2.76in x 0 51-0.83 n • . I 170.85mm x 50-70mm x 13-21 mm),decentralized.IP67 "-" Cable 4mm•Solar.able:(,)R43.3in(1100-m)„)e43.3 in(1120mm) ���'vm-, �" Connector Multi-Contact MC4,IP68 ,".mom I OT"""-' Q.PEAK DUO BLK-G5/SC 310-320 POWER ELECTRICALGHARACTERISTIGS POWER ofo 315 sell MINIMUM PERFORMANCE AT STANDARD TEST CONMTONS,STC'(POWER TOLERANCE w5 W/-AW) Power atMPP' PW, MI 310 315 320 Q.ANTUM SOLAR MODULE RMrt Circuit Current' la IAI 9.83 9.89 9.94 Open Clnup Vallee VM fVl 40.02 40.29 40.56 Cwrenl at MPP' I,x. G1 9.36 9.41 9.47 VAIMee at MPP' Vv., IV] 33.12 33.46 33.80 The new Q.PEAK DUO BLK-G5/SC solar module from Q CELLS impresses ERlnl.ney n %I zla.a ata.7 e19.o thanks to innovative Q.ANTUM DUO Technology,which enables particularly MINIMUMPERFORMANCEATNORMVEopERAI1NGCONDEO$es,NOC' high performance on a small surface,and a black Zep CompatibleTM frame Peer x MPP' PW. (WI 229.7 233.5 237.2 design for improved aesthetics,easy installation and increased safety. R soon elroob CAe.m a, AI 93 97 8.02 Q.ANTUM's world-record-holding cell concept has now been combined Open Circuit Voltage v„ VI 37.43 31.69 37.94 Cwnntat MPP' I„.. [Al ].36 I.47 ].45 with state-of-the-art circuitry half cells and a six-busbar design,thus VeNaee al MPP' Vxw Vl 31.20 31.52 31.84 achieving outstanding performance under real conditions-both with +1001+.(S pnramAML56 Mea,wememraw,a,<eaare,a".Hne.Sx 'COCCI+ n06 .r.,rumAMls6 ',fmcal.ala., aal.a moraine, low-intensity solar radiation as well as on hot,clear summer days. OCELLSPERFOMANCEWARRANTY i7""771. "1"., AT 1 3a oin tp n'Cnst year ,O.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITYa" n l 0.5ax n peryear.AI 931%ot up tal0y.a.s�/ Higher yield per surface area,lower SOS costs,higher power p " An t 65%of n l a p m 25 years classes,and an efficiency rate of up to 19.3%. �a" Aoat toes t sore:e„ FmI w0i ioe s inaccosmnce with thewanamre ins oe InaOccus sales orgniaanonmroutINNOVATIVE ALL-WEATHER TECHNOLOGY respective country. e ,� \� Optimal yields,whatever the weather with excellent low-light .wrw trwl and temperature behavior. ,• ,. w Tomcat module T0conditions ondnio under low 0irradiance0 im)<oMitions,n S "'"" """"" '� comparison to STC cone Ions(25'C,IOOO W/m'1. riP ENDURING HIGH PERFORMANCE f"-", "' GULLS „- �_ ,J TEMPERATURE COEmCIENTs III Long-term yield security with Anti LID and Anti PID Technology'. 1=11 Temperature Coefficient of I a I%/RI +0.04 Temperature Coefficient of v. p 1%/E1 -0.28 Hot-Spot Protect and Traceable Quality Tra.QT"e. PROPERTIESTemperature FOR SYt of STEM V I%/EI -0.37 Normal OpenNee Cell Temperature NOCT IT 113 z5.4(45 x3°C) A EXTREME WEATHER RATING V FOR SYSTEM DESIGN U High-tech aluminum alloy frame,certified for high snow Maximum System Voltage A,,,Maximum 1000(IEC)f 1000(ULl Safety Clan II x (5400 Pa)and wind loads(4000 Pa)regarding IEC. `oppgT/ Maximum Series FAIR Rating [ADC] 20 FIra RatingC(IEC)/TYPE 11Uu k Q 6 Design Mal,Wen(ULL' IIboM'I 50(2400Pa) Permitted module temperelun -40°F up to+185°F 0 A RELIABLE INVESTMENT N®G" on continuous duty I-40°c op to+85°C) s O " Design load,pull(UVImNPI 50(2400Pa) 'see installation manual Inclusive 12-year product warranty and 25-year ru linear performance guarantee. peafieN-6 QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION i UL 1103:CE-compliant: Number of Modules per Pellet 26 =' F STATE OF THE ART MODULE TECHNOLOGY inc 61215(Ed.21:IEd 61/30(Ed.1).application class A Number of Pallets per 53'Troller 32 Q.ANTUM DUO combines cutting edge cell separation APT teat conditions according to € IEC/TS 62804-1,2015, / C SPe � 'y Number of Pallets per 40'Nigh Cube Contain, 26 p and innovative wiring with Q.ANTUM Technology. method e(-15oov.168h) l C e1P � Pallet Dimensions(L x W x N) 69.3in x 45.3in x 46.9in See data sheet on rear ice further ` c us (1760tomx I150mmx1190tom) THE IDEAL SOLUTION FOR: Information. Pallet Wei& 12681bs(575 kR) = Radian arrays MOM Installation instructions must.followed.see the installation and operating manual on information contact our tecnnical service department for further on approved installation and use on of this product. rcindustrial ® iev buildings Hawke O CELLS Amapa Inc. A C 300 Spectrum Center Drive.Suite 1250.Irvine.CA 92618.USA I TEL+I 969 108 59 96I EMAIL in9uiry0us.p-cens.com I WEB www.p-cells.us Engineered in Germany Q`ELLS