Loading...
HomeMy WebLinkAboutEngineered Plans - 2019TBM = EL. 20.2 TOP OF CONC. BND. f Permit valid for RVI"AilL 01 SFPIR SV�ffti1� ONLI, disc to state and I "' d ,.1}tic a tunic ex. Board of ftealth item tial .ata io.ai is e gulled tatt any to m k` 01"gatiml, io sewaLt hu difies at E n s4r int s eS �Htmg. i N aruloaith tIra It it'._, at I of PPIV V LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE TEST PIT SCALE: 1"=20' SOUTH YARMOUTH /�71:71 r ate a tate ROUTE 28 18.7 LOT 1 AREA=14,374 S.F. CHARLES )I f 19.! STREET Jae 19.5 �' 3 EXIST. I 313R DWELLING � I T.O.F. @ EL. 19.6 20.0 �ry BED Z 19.02a RM LIV RM KIT BED PROP. 1,50OG RMmrr BED SEPTIC TANK 3-S� _ PORCti FLOOR PLAN 19.3 DECK BENCH MARK _.-OP OF FOUNDATION 20.0 JSGS DATUM ASSUMED a 0 W Of GAR 1 I f I I I I I I I I I 1 I SURVEY CONDUCTED BY. WELLER AND ASSOCIATES LOCUS MAP LOCUS INFORMATION PLAN REF: 95/85 TITLE REF: 8067/0021 PARCEL ID: MAP 070 PAR. 106 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 3 CHARLES STREET SOUTH YARMOUTH, MA PREPARED FOR EST. OF SUSAN KENNEDY/ READY ROOTER EXC. NOVEMBER 30, 2019 70,�IIASS,IC O � �iI MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com ELEV. TOP FOUNDATION (Existing) 20.0 ,-F.G.EL- 19.60 INV. 18.08 INV. 17.2 1 F.G.EL 19.35 TEE'S ARE TO BE 4" SCH 40 PVC NOTE PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3' OF FINISH GRADE FINISHED GRADE (19.0) F.G. EU 19.0 INV. 16.45 INV.17.00 INV. PROPOSED DB -3 DISTRIBUTION BOX (H20) PROP. 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK/D-BDX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED GENERAL NOTES: I. ALL CHANGES TO THIS PUN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN DOGIEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE DIVIRONi41FAL CODE. TITLE V. AM ANY APPLICABLE LOCK RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE 6MCKFI LED PRIOR INSPECTION MO APPROVAL BY THE BOARD OF HEALTH AND THE 4. ANY ENGINEER. ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SIW L BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. S. THE DESIGN ENGNM IS NOT RESPGISIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR 9. T SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE PULPED. CRUSHED AND REMOVED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER COMFIGITION 12. INS PUN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND 5 NOT TO BE CONSIDERED A PROPFRIY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4- SCH 40 0 1/8 -/FT (UISSS WECf1ED) SEPTIC SYSTEM PROFILE MAINTAIN 2R MIN SLOPE OVER LEACHING AREA 2. OF 3/8' DDUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC 1% MIN.) 2' EPN. DEPTH 16.25 INV. ELEV.= 15.75 / 1 2 X 8.5' 3/4" - 1_1/2• DOUBLE WASHED 4 I / EFFECTIVE LENGTH = 25' 1 TOP CONC. ELEV.= 16.75 INV. ELEV.= 15.75- j I BOTTOM EL.= 13. SEPARATION 5.50 FT. OF TESTHOLE EL: 8.50 SOIL LOGS DATE: NOVEMBER 20, 2019 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: PHIL RENAUD, YARMOUTH HEALTH DEPT Bev. TP -1 DDeb 19.0 A LOAMY SAM 0' 18.25 10YR 3 9' B LOA0MY18 1 5/9AN8D 18.42 31" C MEDIUM SAND PEIIC TEST 2.5Y 7/3 0 IL 14.50 8.50 126" PFRC RATE <2 MN/K (*Cl* NO" NO GROUNDWATER OBSERVED • L Darton IL Mr,Vw, R.S. CSE, hereby ow Wy Lal I am ounwOJy aWp d by MADEP Panum* to 310 CUR 18017 m owWuct *a evokod es and dat the oboes I 'b'o' bw bw pwformed 1V aw oo amour MM the ngiwrwAs of 310 CMR 15.017. 1 fuNw owllly Umt I twA pawl the Sol Eva. Ex In Ootnbw, IM. BREAKOUT ELEV.= 16.75' 3.75' 5 FT. 3.75' EFFECTIVE WIDTH SOIL ABSORPTION SYSTEM (SECTION) (500 GALLON LEACH CHAMBER) DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE. <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR - DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTI: TANK: 550 gPd x 20OX - 1,100 9M USE PROP. 1,5006 SEPTIC TANK LEACHING AREA REQUIRED: (330)/0.74 - 445.94 S.F. USE TWO (2) 500 GALLON PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 25' L x 12.5' W x 2'D BOTTOM AREA: 25 x 12.5- 312.5 SF SIDE AREA: (25 + 12.5) X 2 X 2 - 150 SF TOTAL SQUARE FEET PROVIDED - 462 vs. 445.94 REWD DESIGN FLOW PROVIDED: 0.74(462 S.F.) - 342.25 G.P.D. vs. 330 G.P.D. roq'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 3 CHARLES STREET, SOUTH YARMOUTH, MA Prepared for: Est. of Susan Ke edy/Ready Rooter Exc. Design and Site Pim by: SCALE DRAWL! DATE MEYER ASOAAS,YAAC. N.T.S. DMM 11/30/19 Po BOX 961 REV DATE EASTSMDH7CN,, AM 62537 CHECKED SHEET N0. 50I.W&892E DMM 2 of 2