HomeMy WebLinkAboutEngineered Plan - 2019GENERAL NOTES: SOIL TEST LOGS
TEST HOLE 1: EL=23.2±
A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM .
UNLESS H-20 COMPONENTS ARE USED.
B.) THE DESIGNER WILL NOT 13E RESPONSIBLE FOR THE SYSTEM A5 DESIGNED UN-
LE55 CONSTRUCTED AS SHOWN. ANY CHANGES SHALL BE APPROVED IN WRITING.
C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL
UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK.
DEPTH FROM
SURFACE
(INCHES)
SOIL
HORIZON
501L
TEXTURE
(USDA)
SOIL
COLOR
(MUN5ELL)
SOIL OTHER
MOTTLING
0-18
Cf
Fine Loamy Sand
----
NONE
18-32
B
Loamy Sand
IOYR7/8
NONE
32-130
C I
Coarse Sand
I OYR7 4
NONE
x 12.34 EXISTING SPOT GRADE
FFN ND
24x5 PROPOSED SPOT GRADE
X 22.8
- w- WATER SERVICE LINE
o
--o- OVERHEAD UTILITY SERVICE
UTILITY POLE
24,0
CONSTRUCTION NOTES: TEST HOLE 2: EL=22.7±
1.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE,
TITLE 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH.
2.) SEPTIC TANK(5), GREASE TRAP(S), D051NG CHAMBER(5) AND D15TRI13UTION
BOXES) SHALL BE SET ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY
COMPACTED; OR ON A G INCH CRUSHED STONE BASE.
3.) SEPTIC TANK(5) SHALL MEET A5TM STANDARD C 1 127-93 AND SHALL HAVE
DEPTH FROM
SURFACE
(INCHES)
0-22
501L
HORIZON
Cf
501L
TEXTURE
(USDA)
Fine Loamy Sand
501L
COLOR
(MUN5ELL)
SOIL OTHER
MOTTLING
NONE
22-34
B
Loamy Sand
I OYR7 8
NONE
34-125
Cl
I Coarse Sand
I 0YR7 4 I
NONE PERC 47"• <2 MINAN
SEPTIC TANK
32 EXISTING CONTOUR
2a.a`�f ��
32 PROPOSED CONTOUR
22.1 x
x 12.34 EXISTING SPOT GRADE
FFN ND
24x5 PROPOSED SPOT GRADE
X 22.8
- w- WATER SERVICE LINE
AT LEAST THREE 20" DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE DOT -
TOM OF THE SEPTIC TANK TO THE FLOW LINE SHALL BE 48". DATE OF TESTING: 10/31/2019
4.) SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL EXTEND A MINIMUM OF G" PERCOLATION RATE: LE55 THAN 2 MIN/INCH IN 'C I' LAYER.
ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE WITNES5ED BY: ROBERT REEDY, EIT, J.M. ORALLY D ASSOCIATES, INC.
CENTERLINE OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE. PHIL ENCOUNTERED YARMOUTH HEALTH DEPARTMENT
NO WATER ENCOUNTERED
5.) RAISE COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST USE A LOADING RATE OF 0.74 G7D/5F FOR SIZING OF 501L ABSORPTION SYSTEM.
CONCRETE WATER TIGHT RISERS OVER INLET AND OUTLET TEES TO WITHIN G" OF
FINISH GRADE, OR AS APPROVED BY THE LOCAL BOARD OF HEALTH AGENT.
G.) PIPING SHAD. CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL
BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LE55 THAN 1%.
7.) DISTRIBUTION LINES FOR SOIL ABSORPTION SYSTEM (AS REQUIRED) SHALL BE FLOOR PLAN LAN
4" DIAMETER 5CHEDULF 40 PVC I AID AT 000.9i FT/FT- I INF SHAI_I_ BF CAPPFD
AT END OR A5 NOTED,
8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST
2' BEFORE PITCHING TO 501L ABSORPTION SYSTEM. WATER TEST DISTRIBUTION
BOX TO A55UU EVEN DISTRIBUTION.
9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM SUMP OF G" MEASURED BELOW
THE OUTLET INVERT.
10.) BASE AGGREGATE FOR THE LEACHING FACILITY SHALL CON515T OF 3/4" TO
1-1/2" DOUBLE WASHED NATIVE STONE FREE OF IRON, FINES AND DUST AND SHALL
BE INSTALLED BELOW THE CROWN OF THE DISTRIBUTION LINE TO THE BOTTOM OF THE
501L ABSORPTION SYSTEM. 13A5E AGGREGATE SHALL BE COVERED WITH A 2"
LAYER OF 1/8" TO 1/2" DOUBLE WASHED NATIVE STONE FREE OF IRON, FINES AND DUST.
1 1.) VENT SOIL ABSORPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50 FEET;
WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS, PARKING AREAS,
TURNING AREAS OR OTHER IMPERVIOUS MATERIAL; OR WHEN PRESSURE DOSED.
12.) SOIL ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9" OF
CLEAN MEDIUM SAND (EXCLUDING TOP501Q.
13.) FINISH GRADE SHALL BE A MAXIMUM OF 3G" OVER THE TOP OF ALL SYSTEM
COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX, DOSING CHAMBER
AND SOIL A550RPI ION SYSTEM. SEPTIC TANKS SHALL HAVE A MINIMUM COVER
OF 9".
14.) FROM THE OF-IN5TALLATION OF-THE-501L-AB5ORPTION SYSTEM UNTIL
RECEIPT OF A CERTIFICATE OF COMPLIANCE, THE PERIMETER OF THE SOIL ABSORP-
TION SYSTEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH
AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM.
15.) EXISTING WA5TELINEO)i INSTALLER TO CONFIRM WA5TELINE(5) BY WATER TESTING
WITHIN THE DWELLING PRIOR TO SETTING ANY SYSTEM COMPONENTS.
I
INSPECTION NOTE:
PRIOR TO FINAL INSPECTION BY THE ENGINEER, 5Y5TEM
NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS.
FLOW PRO FI LE:
NOT TO SCALE
18" DIAMETER CONCRETE COVERS
RAISED TO WITHIN G" OF FINISH
TOP OF FOUNDATION GRADE (OR AS NOTED)
EL=24.8± (5EE NOTE #5)
Proposed EL=23.7 ±
NOT TO SCALE
MAIN FLOOR (UNFIN. 35MT),
ONE (I )COVE. 1�1.
TO WITHIN G" OF FINISH GRADE
Bath Bed
Hall
I 8ed� Bed
SAS DETAIL:
SCALE: I = 1O
EL=23.4•* \ r --Proposed EL=23.2±
35" Proposed
(9" Min - 3G" Max)
SYSTEM DESIGN CALCULATIONS:
SEWAGE DE51GN FLOW]
3 ROO LING @ 110 GPD = 330 GPD
LEACHING CAPACITY REQUIRED
3 BEDROOMS (MAX.) @ I 10 GPD = 330 GPD REQUIRED
SEPTIC TANK CAPACITY REQUIREDo
DAILY FLOW = 330 GFD @ 200% = GGO GAL. REQUIRED
SEPTIC TANK CAPACITY PROVIDEDi
1500 GALLON SEPTIC TANK (MIN. ALLOWED)
LEACHING CAPACITY PROVIDED
ONE (1) 25.0'X 12.b3' X 2.0' LEACHING CHAMBER CAN LEACH:
Vt=[(25.0 X 12.83) + (25.0 X 2.0)2 + (12.83 X 2.0)2] X 0.74 GPD/5F=349.28 GPD
349 GPD>330 GPD REQUIRED
NOTE: A GARBAGE DISPOSAL 15 NOT PERMITTED WITH THIS DESIGN.
N5TALb
5. YARMOUTH,
MA
ON I) - 1500 GALLON SEPTIC TANK
ONE (1) - 3 OUTLET DISTRIBUTION BOX (H-20 Rated)--��
TWO (2) - 500 GALLON LEACH CHAMBERS WITH 4' OF STONE ALL AROUND
m
NOT TO SCALE
LOCUS
ca
n-
-
PLAN BOOK 190 PAGE 79
-
DEED BOOK 32075 PAGE 323
o
ASSESSORS' MAP 78 PARCEL 25 1
GAS SERVICE LINE
- --
-
BENCHMARK:
TP
®
Top of Concrete Bound tL
LEGEND
EL=21 .G± (NAVD88 Datum)
5T
SEPTIC TANK
32 EXISTING CONTOUR
2a.a`�f ��
32 PROPOSED CONTOUR
22.1 x
x 12.34 EXISTING SPOT GRADE
FFN ND
24x5 PROPOSED SPOT GRADE
X 22.8
- w- WATER SERVICE LINE
o
--o- OVERHEAD UTILITY SERVICE
13a•g3
-U-
UNDERGROUND UTILITY SERVICE
1
/
Reserve
- G-
GAS SERVICE LINE
- --
-
x 22.1
TP
®
TEST HOLE / BORING LOCATION
23.3 "
:.FNa• 24 84.1 rnt 'cp®zza
��
BULKHEAD
5T
SEPTIC TANK
24.2 ��,:.,�� \ ®z .2
2a.a`�f ��
De
DISTRIBUTION BOX
\,
sAs
SOIL ABSORPTION SYSTEM
OX\OHN M. CO
y` Exlstmg Cesspool JOHNIV-
�i 22OX\.2 OIP TO BE PUMPED, FILLED, CRUSHED ;f MVV.._; O'DEILLY
FNDt ABANDONED IN PLACE f O'REILLY CIVtL
Garage
a '15tmg \
of Slab
1
/
Reserve
RESERVED FOR FUTURE
\
LAYER OF 1 /8" - 1/2" NATIVE STONE
BH
BULKHEAD
\ b prove
x 24. 0
I
/ O
5
STEP
ave
P \
��� �
Rf�BRVE I
o
�I9.50�:'
UTILITY POLE
24,0
C5 ������� �5 2,,
I-
®
*Cr
CATCH BASIN
O
5
I
FIRE HYDRANT
/�///
N
`.
5T
5A5
x 21s
WELL
GA5 BAFFLE
®_ _ --
- p
DRAIAIAGE MANHOL€---
23.0
w=-w_ww24.3
CONCRETE BOUND, FOUND
w w-' r
�5t�np�elhng Concrete x �t
.�
O
IRON PIPE, FOUND
dation
Tof Found+ Patio
ot'
x 22.8
= -
TOP Of BANK
rn
O
9 \ �L 24 8 \
.
-\
-x-x-
LIMIT OF WORK,
1 G'
(END VIEW)
SEPTIC TANK
D -BOX
FENCE
LEACHING CHAMBER EL= 12.3± BOTTOM OF TEST PIT #2
13"
H-20
i
^^^
EDGE OF CLEARING
LOT I-8
x 20.9
OAK TREE
eco
Area= 14,000 SF±
22.7
23.6
o� x 23s%
x 21.8
22 .IP
FND
�O
ON
'J
r/
o
oc`OF
OF fV"1'c
OX\OHN M. CO
y` Exlstmg Cesspool JOHNIV-
�i 22OX\.2 OIP TO BE PUMPED, FILLED, CRUSHED ;f MVV.._; O'DEILLY
FNDt ABANDONED IN PLACE f O'REILLY CIVtL
NO. 46735 rrr � N0. 36206
F
Permit° valid for RFPAIR OF SEPTICSYS°TF.111
due'to.State and Local septic variances. � F,,� "C� r ` b04 LE S
Board of llealth review and approyal isrequired',for
PLANany future additions/rcn(iv'itions/alterations to
sewage facilities and/or structures/dwelling.
SCALE 1 "=20'
THIS AREA IS SE VED Varmouf6 Health Dp arfinent
BY TOWN WAT R. ARPROV:E
P/) 47 Shane Cooper
NFaYte ; Date 265 Wckenden Street, 2nd Floor, Providence; RI 02903
SITE SEWAGE DISPOSAL SYSTEM DESIGN
84 WITCHWOOD ROAD, SOUTH YARMOUTH, MA
PROPERTY 15 LOCATED WITHIN
A ZONE 2 OF A PUBLIC WATER 5UPPLY J. M. OTEILLY & ASSOCIATES, INC.
Professional Engineering & Land Surveying Services
1573 Main Street - Route 6A
0 20 40 60 P.O. Bos 1773
(508)896-6601 Office Brewster, MA 02631 (508)896-6602 Fax
PATE: SCALE: 6Y: CHECK: JOS NUMBER:
SCALE I "=20'
GNWobs\Cooper - 8512 - 84 Witchwood Rd. 5. Yarmouth\dwq\8812.5D5 PLAN.dwg 12-12-12019 AS Noted RFR! .IMO SMO -88 1 2
J2"
LAYER OF 1 /8" - 1/2" NATIVE STONE
22.1-±-
20.50
1 O1,
14"
20.25
�I9.50�:'
�/
3/4" - 1-1/2" NATIVE STONE
(EXISTING)
3"
T 4
O
20.00
19.83
/�///
N
/
GA5 BAFFLE
2
„ DROP
17.50
USE TWO (2) 5HOREY PRECAST
Longest Run
500 GALLON LEACH CHAMBERS 5.21±
WITH 4' OF NATIVE STONE AROUND
1500 GALLON
2'
DB -3
1 G'
(END VIEW)
SEPTIC TANK
D -BOX
LEACHING CHAMBER EL= 12.3± BOTTOM OF TEST PIT #2
H-20
25.0'x 12.53'x 2.0'
NO. 46735 rrr � N0. 36206
F
Permit° valid for RFPAIR OF SEPTICSYS°TF.111
due'to.State and Local septic variances. � F,,� "C� r ` b04 LE S
Board of llealth review and approyal isrequired',for
PLANany future additions/rcn(iv'itions/alterations to
sewage facilities and/or structures/dwelling.
SCALE 1 "=20'
THIS AREA IS SE VED Varmouf6 Health Dp arfinent
BY TOWN WAT R. ARPROV:E
P/) 47 Shane Cooper
NFaYte ; Date 265 Wckenden Street, 2nd Floor, Providence; RI 02903
SITE SEWAGE DISPOSAL SYSTEM DESIGN
84 WITCHWOOD ROAD, SOUTH YARMOUTH, MA
PROPERTY 15 LOCATED WITHIN
A ZONE 2 OF A PUBLIC WATER 5UPPLY J. M. OTEILLY & ASSOCIATES, INC.
Professional Engineering & Land Surveying Services
1573 Main Street - Route 6A
0 20 40 60 P.O. Bos 1773
(508)896-6601 Office Brewster, MA 02631 (508)896-6602 Fax
PATE: SCALE: 6Y: CHECK: JOS NUMBER:
SCALE I "=20'
GNWobs\Cooper - 8512 - 84 Witchwood Rd. 5. Yarmouth\dwq\8812.5D5 PLAN.dwg 12-12-12019 AS Noted RFR! .IMO SMO -88 1 2