Loading...
HomeMy WebLinkAboutEngineered Plan - 2019z +fir N Ex STING CONTOUR: ---- SEPTIC SYSTEM DESIGN PROPOSED CONTOUR: ............. CHpNO DR Z EXISTING SPOT ELEVATION: 25.5 FLOW ESTIMATE: GRAS R PROPOSED SPOT ELEVATION: 25.5 3BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY ryG 2 TEST HOLE: * Z� N UTILITY POLE: -4- LOCUS rn nFENCE LINE: _ SEPTIC TANK: Z HYDRANT: b- 330-GAL/DAY X2 DAYS= 660 GAL RETAINING WALL; o P`,GO 0?1Ir- 10 USE 00 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: LOCATION MAP 25.0' USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH LOT 9 (22,148 SF) - 4' OF STONE ALL AROUND (25'x 12,8'x 2' EFF. DEPTH) ASSESSORS MAP: 64 PARCEL: 45 LAND COURT CASE 35776C•' SIDE AREA: (25'+ 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAUDAY ................ BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) =_937 GAL/DAY LEACH AREA DETAIL CAPACITY = 349 GAL/DAY Permit valid for REPAII+ ()F• 9EPT1C. SYSTEM;;; QNLY, due to State and i -cal' 84tic', variances. Board of'ilealth review and .ggiroval. is required for any future additions/renij, lions/alterations to sewage facilities anil/or structu, es/dwOling- , alealth IDupartiitent A1jiiR0 V/Y'X�- Uafe Name::: CHANDLER GRAY ROAD 101-- E�of Parent -_-"-.183-43'57" - 136.50' t X102 00 0 0 o < t� E �G wJ top fna`,NO ?1rt a 103 %00 G �� 9 screen E PAVED DRIVE o ch 12' pine t gT eXisting 16" pine septicCD - i th-1 1 l 12" oak / 18" pine ra I �� , __ ____ Edge of l ~, \�, ------! 172.03,! --- /' S 85°37'10" W 101 100 102 �Z m BENCHMARK AT LEFT CORNER OF BOTTOM CONC. STEP ELEVATION = 103.79 SEPTIC SYSTEM SECTION FIRST FLOOR 104.21 TOP OF ° FOUNDATION 100.9 ,... ELEV. ', A 100.25 ELEV. BED J'REO'OM�ROOM LIVING ROOM BED bath DINING ROOM bath KITCHEN screen porch COVERS WITHIN 6" OF FINISHED GRADE (EXISTING) 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" U 13" DOWN OUTLET: 6" UP, 14" DOWN EXISTING FLOOR PLAN (1 MAX. 1/4" per ft COVER INj 00.0 1/4" per ft ELEV. 99.94 99.77 ELEV. D -BOX ELEV. 16" OF STONE UNDER OR MECHANICALLY COMPACTED) / ELEV, -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS MCLELLAN, P.E. WITNESS: 10-23-19 DATE: PHIL RENAUD GARAGE PERCOLATION RATE: < 2 MIN/IN 0 F MASS9 tib, 1 o TERRY F oANN WARNER �N No. 38721 ) x 2" PEASTONE OR FILTER FABRIC - 3/4" - 1 1/2" DOUBLE WASHED STONE INSPECTION PORT ,-- ELEV.= 100.33 I4wi1I°°° °1.11 1 97.5 H H ELEV. 25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' EFF. DEPTH) TH-1 102.0 ELEV. FILL O/A HORIZON LOAMY SAND 10YR 4/1 100.9 B HORIZON LOAMY SAND 10YR 5/8 99,7 C HORIZON MEDIUM SAND . PERC AT 44" 2.5Y 7/4 132" 1 1 91.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. -SCHEDULE 40 - 4" PVC -PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. - - - - 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY, 13. EXISTING LEACH PIT IS TO BE PUMPED AND REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. SITE PLAN i LOCATION: 19 CHANDLER GRAY RD., W. YARMOUTH, MA PREPARED FOR: JOHN DIAUTO „ _ ISI DATE: 10-25-19 SCALE.. 1 - 30. BASS RIVER ENGINEERING THOMAS J. McLELN P.E. P.O. BOX 1163 EAST DENNIS MA 02641 6 1 508-364-9048