HomeMy WebLinkAboutEngineered Plan - 2003r. . It c Or. %..., -- LOCUS MAP ACCESS COVEPS MUST BE WITHIN 6* OF FINISH GRADE 101.5 FIRST 2' TO n BE LEVEL -7 ` ~ BAS I IN �¢, k 110' III �11 96.0 3 OUTLET 5 HIGH CAPACITY INFILTRATOR '° CHAMBERS W/3.5'± STONE AROUND D -BOX 1500 CAL / 0 ' • x 38'1 x I O 'd SEPTIC TANK 6' CRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE 9- MINIMUM. 3' MAXIMUM COVER MIN 2' OF PEASTONE 3/4' - 1 //2' DIA. DOUBLE WASHED STONE 7'^'^'^ INVERT ELEVATIONS: INVERT AT BUILDING. 98.17 INVERT IN SEPTIC TANK: 97.75 INVERT OUT SEPTIC TANK: 97.5 INVERT IN DIST. BOX: 97.3 INVERT OUT DIST. BOX: 97.13 INVERT IN LEACH CHAMBER. 96.83 BO T TOM OF LEACH CHAMBER: 96.0 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE *I: 89.9 DESIGN CRITERIA DES / GN FL 0W : 3 BEDROOMS AT 1/0 G.P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200x - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 M / N/ I NCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED PROVIDED: 5 HIGH CAPACITY INFILTRATOR CHAMBERS W/3.5't STONE AROUND. A-460 S.F. 460 S.F. x 0.74 - 340 GPD SOIL TEST PIT DA TA INDICATES INDICATES M PERCOLATION OBSERVED TEST GROUNDWATER TP 0/ CATCH BASIN RIA! -9R. 90 0 I0 20 40 44' 12C' I NO WATER DATE: JUL Y 2. 2003 TEST BY: STEPHEN HAAS WITNESSED BY: DAVID FLAHERTY PERC RATE: l 2 MIN/INCH GENERAL NOTES: I. THIS PLAN /S FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYS TEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE S/ TF. PLAN. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS L OCA TED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OP APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. I -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCA T ION OF UNDERGROUND UT / L / TIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. C�L��MC�D SEP 1 6 2003 HEALTH DEPT. S E P T/ C Y,5 7 -EIV 0 E_ 5/ G /\/ 47 DE-ACO/\1 STREET. MAP 79. PARCEL 3 PRE'PA REO F_ OR RALPH C,APC7-OS7T0 SC.4 L E : / " - 20 A UOUS T / / 2003 EAGLE SUI= VE�T"1 NG, I NC 923 Route 6A Ya rmau t hpo r t NAA 02675 ✓�I�J1����'�` ( 508) 362-8132 ( 508 ) 432-5333 0. HORIZON TEXTURE COLOR 99.9 LOAMY IOYR 1 SAND 3/3 98.6 p LOAMY 7. SYR (� D SAND 4/6 1 28 • ............... ... 97.6 O C l MEDIUM IOYR '�J y SAND 5/8 CATCH BASIN RIA! -9R. 90 0 I0 20 40 44' 12C' I NO WATER DATE: JUL Y 2. 2003 TEST BY: STEPHEN HAAS WITNESSED BY: DAVID FLAHERTY PERC RATE: l 2 MIN/INCH GENERAL NOTES: I. THIS PLAN /S FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYS TEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE S/ TF. PLAN. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS L OCA TED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OP APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. I -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCA T ION OF UNDERGROUND UT / L / TIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. C�L��MC�D SEP 1 6 2003 HEALTH DEPT. S E P T/ C Y,5 7 -EIV 0 E_ 5/ G /\/ 47 DE-ACO/\1 STREET. MAP 79. PARCEL 3 PRE'PA REO F_ OR RALPH C,APC7-OS7T0 SC.4 L E : / " - 20 A UOUS T / / 2003 EAGLE SUI= VE�T"1 NG, I NC 923 Route 6A Ya rmau t hpo r t NAA 02675 ✓�I�J1����'�` ( 508) 362-8132 ( 508 ) 432-5333