Loading...
HomeMy WebLinkAboutEngineered Plan - 2019T.O.F. EL.= /_ 12.4'± 8.3' 14.4' 41.9' FINISH GRADE 15.3' 20.4' 60.3' @ FND. EL.= 27.1' 23.9' 51.2' 30.6' 28.6' 21.1' 4" 24.0' 23.6' JJ�E-,\ISTIN') SEWE,`Z PIPE 41.4' 17.4' 14.1' NTRACTOR TO PROVIDE ECIFIED DROP BETWEEN ET AND OUTLET ,C 0,NTRA : TfO N' TO Vf,-_R i_Y E:XISTI.,�G ELI: W%1_1G:. PRIO' _.i.0 A+�Y �^4`C�;I� � ti;1T4b:Y PI,: mIl�.' Fii It= DI"--FERz_NT. PROVIDE EXTENSION RISER WITH COVER OVER INLET & OUTLET TO WITHIN 6" OF F.G.-\ _ F.G. OVER TANK EL. = 10. 1'±v FINISH GRADE OVER D -BOX = 9.5'+- REMOVABLE .5'± REMOVABLE WATER -TIGHT COVER OVER RISER TO WITHIN 6" OF FINISHED GRADE �5" DIA. OUTLET(S) FINISH GRADE OVER CHAMBERS = 9.2' - 9.4' SLOPE @ 2% MIN. OVER SYSTEM - 4" SCHEDULE 40 PVC MIN SLOPE 1% INSPECTION PORT WITH ACCESS BOX TO F.G. (SEE NOTE #21) PROPOSED 4" I 36" M SCH. 40 PVC 9„ MIN. AX. TOP OF SAS = 8.23' I L SEWER PIPE j 7.40 36" MAX. BREAKOUT F ---111 BREAKOUT EL = 7.90 - 73 ^� GENERAL NOTES 3/4" TO 1-1/2" DOUBLE WASHED I. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION STONE TO CROWN OF PIPE METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL 2" OF 1/8" TO 1/2" DOUBLE WASHED CODE AND ANY APPLICABLE LOCAL RULES. STONE OR USE FILTER FABRIC 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. ; PLACE RISERS ON 11 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL CHAMBERS w/PIPED SYSTEM UNLESS OTHERWISE NOTED. INLETS TO 6" OF 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN FINISHED GRADE ELEVATION = 7.90' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 6„ 3" 3" DROP MAX L- _ 00 3 9 PROVIDE WATERTIGHT 2" DROP MIN MIN. SLOPE@1% -( 4" PVC IN FROM JOINTS (TYP.) 0 00, 0 0 j 13" 14" , 4" PVC OUT TO d 00 �� % _ SEPTIC TANK LEACHING FACILITY 0 0 == = 0 00 .._ O CONTRACTOR SHALL , 12" 6" , 1' oo 0 0 0 0 q00 CONTRACTOR CONTRA OUTLET TEE 7.77 MIN. 7.60OQ SHALL VERIFY SIZE 48" VERIFY CONDITION OF AND CONDITION OF EXISTING TEES GAS BAFFLE 6" CRUSHED STONE 4.0� 6,0' 4 0' 2.0' EXISTING SEPTIC AND REPLACE AS OVER MECHANICALLY (TYP.) VARIES (see plan TANK NECESSARY COMPACTED BASE 5 �i OUTLET DISTRIBUTION BOX 6.40' GROUND WATER ELEV.= 2.40' mottlin TO BE INSTALLED ON A LEVEL STABLE LC -6 CHAMBERS _ -- - --� BASE. FIRST TWO FEET OF OUTLET 5' MIN. REQUIRED PIPES TO BE LAID LEVEL. TYPICAL PR CiAIiBER ®FILE 4' PROPOSED (see Gen. Note #23) EXISTING 1,000 GALLON CONCRETE SEPTIC TANK CROSS SECTION VIEW �J y@T- DE (�s AILS g4j .s ,�., r'°y. e a w^ m sus F e s e� -r a+ ® I V I B 4..�. I D E I f \ I L S (H-10 SEP � NIK P G IL -�`IU DIST I -I i(`I G/� I /SIL NOT TO SCALE NOT TO SCALE I ` NOT TO SCALE PLAN NOTES: 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALON TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN T LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN O PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF H j IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. 3.) ENTIRE PROPERTY IS NOT LOCATED WITHIN A MAS APPROVED ZONE II. 4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDED AS A COURTESY FOR THE INSTALLER. INSTALLER SHA VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIG INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIF ENGINEER IF MEASUREMENTS APPEAR TO BE INCORR M 0 N 00 z a- d J SWING -TIES DESCRIPTION CORNER OF STONE (1) CORNER OF STONE (2) CORNER OF STONE (3) CORNER OF STONE (4) CORNER OF STONE (5) CORNER OF STONE (6) HCA I HC -2 I SCA I SC -2 36.9' 35.4' 8.3' 14.4' 41.9' 42.3' 15.3' 20.4' 60.3' 51.1' 27.1' 23.9' 51.2' 30.6' 28.6' 21.1' 44.2' 24.0' 23.6' 16.7' 50.7' 41.4' 17.4' 14.1' 1 � � G THE / \ cp HE OR yl I C \ > N THIS �i \ X-X��� t X48 `� PROPOSED HE ��QBJP / ��' \ '��y R`37 82 \ INSPECTION PORT A na 10' �, TWfN � -� �� '�� 0 MASS f � v • 6 & 8° / TWIN \ma=r PROPOSED SEVEN (7) ! 4z / 12 , 2" I\ -r.� LC -6 CHAMBERS w/ STONE 12 / \ ONLY ] - 181, LL E XISTI"3 LLACii'I• G F=IE.L.D r}1 ,`�b�6 10„ y� 7X9 I \ RTO r^ rO I }''LFi Ji_�.`�'v`rii;:L` ..=E^�i:,i it �--V �(b. \ Y C .;,TED 8-5 s , (�-� j �, ,, 1 _ 8 _ ( REMOVE ALL UNSUITABLE r - j Q `t' 3 D MATERIAL DOWN TO TOP ECT. EiE AEAI'D0" e -ED)-_/ ) . , a` a x.16 CLUSTER ` $ \ 1 0 � OF "B" SOIL & REPLACE w/ / 7x6 \ 18" 3-6-9" 14„ 6 / \ >� ( PER 3CLEA110 COMR 255ARSE (3ND j 8x4 \ \ J - 8x3 \ x4 6) \ - 1 t / I8x0 I (2 (� \ II % 16„ U-5 7x5 ,:, o Y n 8. I I o. 10 �l Cb II {`'t i TWIN / 12" ,17x9 0 Uj 2" f ` .. ` 6„ Ln SC -2 0 8x7 - - - - - SHED 12.2' ,l" CID X \ \ _ .__. -.��, 14 Cp I --,X�i �4) > \� PROP. > EXISTING DeiIl",,!u ION D -BOX ' � 14" I � W E O>, I t a�. tzars DCiv 11-, CLP&T.ER -- _ _ _ _ (5 Y I I :D \i > M >>MHCA� I HC -2 T," - A � W 7- N w >< c TOF = x / 12.4'± X �\ CLUSTF_R U zi Z a QI \ \ }I.i _F //> \ y I 00 N I E,Il ileC 1,Guv CALLOF I \\ i O I \� I 1 I Z I S:'PTI C TAi'YK TO iaO I C) UTILIZED IN i i iiJ DESI�.a's'N - - L___ /#85 / y I I I 1 \ I �' Ln I, \ I EXISTING I \� I q -4 \ \ I � .. 3 -BEDROOM / ( \ \ I I �-' C.B. DWELLING i y 0 1 a> \ j, , I I �: I I T „ \ \ , 10 I ( I \ rn t \ \ o W \ w w V o MAP 33 Q' oe� ► - �\ LOT 257 >,I 49 DECK 10 Co > \ \CHIM./ I- ; [_IHVAC ��--- -MS7-- - - GAS GAS -f- GAS GAS - AS h \\ /6"\/N 1 MAP 33 LOT 256ILO- X � x \\ / I 9x2 13,745± S.F. / / / / > `\ J, V/ \ // // / °- Benchmark �0 ,lb Top Threshold x Elevation =13.48' x N.A.V.D. 88 1 \ 100.00' S85° 43' 12"W X PLAN MAP 33 MAP 33 SITE LOT 255 i n r Baa SCALE: 1" = 10' COX) Parkers River !` = Beach LOCUS PLAN SCALE: 1" = 1000' DESIGN ATA NUMBER OF BEDROOMS (DESIGN) 3 DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 330 GAUDAY DESIGN FLOW x 200 % = 660 GAUDAY USE EXISTING 1,000 GALLON SEPTIC TANK INSTALL (7) LC -6 H-10 LEACHING CHAMBERS w/ STONE SIDEWALL CAPACITY (TOTAL PERIMETER) (1' HIGH) (0.74 GPD/S.F.) = GAUDAY (114.0')(l') ( 0.74 GPD/ S.F.) = 84.4 GAUDAY BOTTOM CAPACITY (FOOTPRINT AREA) (0.74 GPD/S.F.) = GAUDAY (350 S.F.) (0.74 GPD/S.F.) = 259.0 GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 7 TOTAL LEACHING AREA 464.1 SQ.FT. TOTAL LEACHING CAPACITY 343.4 GAL./DAY RESERVED FOR BOARD OF HEALTH USE 0 A/E " )R 12 Pere B 30" a- _t 36„ C .M Loamy Sand 10Yr 4/1 Loamy Sand 10Yr 5/8 _Mottling Standing GW t7a 66" _ Medium Sand 2.5Y 6/6 6.40' 4.90' 4.40' 2.40' 1.90' EAST LONGMEADOW, MA 01028 FEMA FLOOD ZONE AE (ELA 1) COMMUNITY PANEL# 25001CO589J 17. DEED REFERENCE: L.C. CERTIFICATE# 194699 18. PLAN REFERENCES: 1.) PLAN BOOK 229, PAGE 115 2.) L.C. PLAN #38203-A 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 21. A 4" PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TO A DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3" OF FINISH GRADE. A REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS. 22. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 23. IN ACCORDANCE WITH 310 CMR 15.401 -15.405, THE FOLLOWING LOCAL UPGRADE APPROVAL IS REQUESTED FROM 310 CMR 15.212(1): 1.) A 1.0' WAIVER (5.0' - 4.0') FOR THE SEPARATION BETWEEN THE SAS AND ESHGW. LEG E '\.I 50x0' EXISTING SPOT GRADE ------ 50 ------ EXISTING CONTOUR PROPOSED CONTOUR r-50-1 PROPOSED SPOT GRADE O/Flew --- EXISTING OVERHEAD UTILITIES W EXISTING WATER LINE Perinit valid for RI41)AIR OF SEVI'IC_ r'%'S I f N1 GAS EXISTING GAS LINE ONLY, due ' to State' and I ocal septic ariam us. Board of Ilealth reviev, and approval is re(uiied for alay foture addihom►s/reli„%atiogs/altera ions to TEST PIT LOCATION sewage tacilities_and/ot'stru(tores/dv�elling. F,_..w...n EXISTING 1,000 GALLON SEPTIC TANK l'armoutl► 1.9caltll DepartmentI i'� ;;,;�. rr PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE - fJL ke t ( Q PROPOSED H-10 DISTRIBUTION BOX Dat �- O PROPOSED LC -6 H-10 LEACHING CHAMBER REV. DATE o>�P�AN of k4ssgc� JOHN L. v CHURCHILL JR. of N0.48066 rr OF JOHN L. s CHURCHILL JR. �a CIVIL NO. 41807 BY APP -D. DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR: CAPEWIDE ENTERPRISES LOCATED AT 85 NANTUCKET AVENUE YARMOUTH, MA 02664 SCALE: 1 INCH = 10 FT. DATE: DECEMBER 2, 2019 0 5 10 20 40 FEET PREPARED BY: JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 Drawn By: ATB Designed By: MCP I Checked By: JLC --T JOB No. 4926 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF 0 THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 0 0 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. (� 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK 2.0' FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS 3.0' NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH (NP') AND DESIGN ENGINEER. 7.0' 8• ELEVATIONS BASED ON N.A.V.D. 88 DATUM. BENCHMARK ELEVATION OF 13.48' ESTABLISHED I ON TOP OF A THRESHOLD AS SHOWN ON PLAN. END r CHA�'VrIL'ER EIS I� VIEW I 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 1 1 -888 -DIG -SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING V TEST PiT DATA REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM N/A APPROPRIATE AUTHORITY. 0.PERC 1� NO. Phil Reneaud 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED f INSPECTOR: UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR a EVALUATOR: Michael Pimentel, EIT, CSE TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. 4` C.S.E. APPROVAL DATE: Oct. 27, 1999 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. -, DATE: November 21, 2019 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE i1 -j TEST PIT #: MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. ELEV TOP = 7.40' REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, S ELEV WATER = 2.40' (mottling) FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). IN 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND PERC RATE _ < 2 min./inch SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. DEPTH OF PERC = 12" - 30" 16. PROPOSED PROJECT IS LOCATED WITHIN: r!Q ASSESSOR'S MAP 33 LOT 256 _.Fond TEXTURAL CLASS: 1 OWNER OF RECORD: MARTIN F. &MARGARET SCHOENEMANN �f 7 40 annRFSS• 167 ORCHARD ROAD 0 A/E " )R 12 Pere B 30" a- _t 36„ C .M Loamy Sand 10Yr 4/1 Loamy Sand 10Yr 5/8 _Mottling Standing GW t7a 66" _ Medium Sand 2.5Y 6/6 6.40' 4.90' 4.40' 2.40' 1.90' EAST LONGMEADOW, MA 01028 FEMA FLOOD ZONE AE (ELA 1) COMMUNITY PANEL# 25001CO589J 17. DEED REFERENCE: L.C. CERTIFICATE# 194699 18. PLAN REFERENCES: 1.) PLAN BOOK 229, PAGE 115 2.) L.C. PLAN #38203-A 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 21. A 4" PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TO A DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3" OF FINISH GRADE. A REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS. 22. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 23. IN ACCORDANCE WITH 310 CMR 15.401 -15.405, THE FOLLOWING LOCAL UPGRADE APPROVAL IS REQUESTED FROM 310 CMR 15.212(1): 1.) A 1.0' WAIVER (5.0' - 4.0') FOR THE SEPARATION BETWEEN THE SAS AND ESHGW. LEG E '\.I 50x0' EXISTING SPOT GRADE ------ 50 ------ EXISTING CONTOUR PROPOSED CONTOUR r-50-1 PROPOSED SPOT GRADE O/Flew --- EXISTING OVERHEAD UTILITIES W EXISTING WATER LINE Perinit valid for RI41)AIR OF SEVI'IC_ r'%'S I f N1 GAS EXISTING GAS LINE ONLY, due ' to State' and I ocal septic ariam us. Board of Ilealth reviev, and approval is re(uiied for alay foture addihom►s/reli„%atiogs/altera ions to TEST PIT LOCATION sewage tacilities_and/ot'stru(tores/dv�elling. F,_..w...n EXISTING 1,000 GALLON SEPTIC TANK l'armoutl► 1.9caltll DepartmentI i'� ;;,;�. rr PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE - fJL ke t ( Q PROPOSED H-10 DISTRIBUTION BOX Dat �- O PROPOSED LC -6 H-10 LEACHING CHAMBER REV. DATE o>�P�AN of k4ssgc� JOHN L. v CHURCHILL JR. of N0.48066 rr OF JOHN L. s CHURCHILL JR. �a CIVIL NO. 41807 BY APP -D. DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR: CAPEWIDE ENTERPRISES LOCATED AT 85 NANTUCKET AVENUE YARMOUTH, MA 02664 SCALE: 1 INCH = 10 FT. DATE: DECEMBER 2, 2019 0 5 10 20 40 FEET PREPARED BY: JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 Drawn By: ATB Designed By: MCP I Checked By: JLC --T JOB No. 4926