HomeMy WebLinkAboutReview Checklistf
°' TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
; Location: A.M. 12- Lot -Z 3 Zone of Contribution: In_ Out Acreage
�D 1.0( ((.6-be c �ff Commercial: Residential:
Street:
Village: Ok/lfaiY4 Floor Plan: #Bedrooms:
Owner: J YALO 9hadfa 4,7 Installer: /PH /
Address: Phone: v, - 77 J---40-707
Phone:
Builder: Engineer: betora /fiefs,
Address: 7- Phone: 8 : ---..1-?2:)
Phone:
N/A YES NO
1.Required#of copies received 1.----
2.Date of soils exam and percolation test not older than 2 years L.-----
3.4-5
_„i3.4-5 ft of naturally occurring pervious material, above water table ‘..----
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: Q.
1)
6. Benchmark indicated and shown-NGVD if near wetlands /
7. Septic tank minimum 10 ft from foundation, deck Var.: /
/
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: /( ,L/
9.Leaching minimum 100 ft from wetlands Var.: ;
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: -----
11.
/11.Tank/leaching minimum 10 ft from property line Var.: c / �-
12. System meets all other setback requirements Var.: G. { (`
13. Uses adjustment for maximum high groundwater Var.: ✓"
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: L-------
15. System not in top or subsoil(A,B horizons)or 5'removal L-----"'
16.Proposed contours are suitable k.--,/
17. System meets slope requirements-min. 1/8", ' "preferred L-----
18.
l18. System meets breakout requirements PVC liner: ' -i 'all: ,....---
j9. Specified tee sizes are proper,gas baffle on outlet tee .------
20.
./20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
22.System adequately sized for its intended use /....-----
23.Minimum 6"stone or compacted below tank and dbox t-------'
24.Manhole covers within 6"of grade,pump chamber cover to grade L/'
25. Inspection port on plastic chambers/leach field • k....-----
26.
/26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size �-
28. Septic tank/pump chamber to be factory waterproofed /l
29.Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial: !�`
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature WS Q
33.H-20 loading is subject to vehicular traffic, groundwater
34. Title V Application and permit fee, installer signature -------
35.
-/35.Foundation footing min. 2 feet above adjusted ground water for new house .___.---
36.Deed Restriction required max. #bedrooms: max. flow: gpd ------
37.Check area lots for groundwater/Label groundwater in Assessor's Map _,----
Plan
,,.iPlan reviewed by: (--„,
(c 's'
j 6/03/03