Loading...
HomeMy WebLinkAboutEngineered Plan - 2019FOUNDATION PRECAST H-10 RISERS (IYP.) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 38.0 10" EXISTING 14" TEE SEPTIC TANK** TEE GAS BAF EXIST. SEPTIC TANK *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEN D 99— EXISTING CONTOUR X 991 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 �a. _0� TEST HOLE 2� SLOPE OF GROUND �o UTILITY POLE Y FIRE HYDRANT NOTE. NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 12/5/19 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 4 36.0' A LS 30" 1OYR 4/2 B LS 41's 1 OYR 5/6 32.6' C PERC MS 1OYR 7/4 132" 25.0' NO GROUNDWATER ENCOUNTERED LICE #19-399 SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. H-20 CAST IRON COVERS TO GRADE 2% SLOPE REQUIRED OVER SYSTEM 136.0'-37.9 VENT W/ CHARCOAL FILTER WATERTEST D'BOX FOR LEVELNESS BLOCKS OR MIN. 2" WALL THICKNESS PRECAST RISERS 4"OSCH40 PVC PIPES LEVEL IST 2' 4'— COMPONENTS INVERT IN 31.82' ENDS (NP') SIDES 32.92' O°000°O° .. ... .. ... . ... .. ... .. :. .' ,. ... .. .. ''. 00 O O 32.3±'* 000000000000 6" MIN. SUMP oQoo ®®®®jam®j®® ®® EA ®� 0000°o°o -!g. 0�0 > O°O°O°O OLS®®®® �� ® ® !°0000°O° _ogo�o„o_ 12" MIN. INT. DIM.°0000000 ®®® yj®q�� °0000°o° J J > o°O°O o ®®®®®®®®®®® ®®®®®® ®®L7®°o°o°o°o DO°0°000 32.09 1.92 °°°°°°°° M" 00 29.82 I ' H-20 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [21) ( 1 % SLOPE) ( 1 % SLOPE) OR H-20 LEACHING 21' D' BOX 12' FACILITY **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE—USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE Scale:1 "= 20' 0 10 20 30 40 50 FEET 25.0' BOTTOM TH-2 NO GROUNDWATER FOUND ***INSTALLER TO CONFIRM NO GROUNDWATER DOWN TO EL. 24.8 MINIMUM NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -2Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 151 PARCEL 87 VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405 1b: SAS TO BE > 3' BUT < 6' BELOW FINISH GRADE (VENT AND H-20 PROVIDED) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN—FLOW: 3- BEDROOMS Q 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **RE—USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD T9Tv 472 S.F. 349 GPD Permit valid for REPAIR OF SEPTIC SY ' EM ONLY, due It state and Local aepticWE-e4rian• 500 GAL. LEACHING CHAMBERS ACME OR EQUAL Board of Health review and approval is ,�.-e��?�• ( ) any future additions/renovations/alteaWITI'-I' 40 3TONE ALL AROUND sewage facilities and/or structures/dwelling. Yarmouth 11calth Departmcr:t APPROVED MA A P&OV D DATE BOARD OF HEALTH Name ate TITLE 5 SITE PLAN OF DANIEL A. OJALA, P.E., P.L.S. 20 BAYRIDGE DRIVE YARMOUTI-IPORT, MA PREPARED FOR JOHN ADELIZZI DATE: DECEMBER 11, 2019 off 508-362-4541 I fax 508-362-9880 downcape.com dOWO cape enghleerifg, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 19-399 ADELIZZI.DWG 0 c 3 0� ftf hGM Locus o O Ktng's Wary a�� �'� �' ��� ��cS_ -bond O setucket �o oo, 0 �a. •may cc �o. LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 151 PARCEL 87 VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405 1b: SAS TO BE > 3' BUT < 6' BELOW FINISH GRADE (VENT AND H-20 PROVIDED) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN—FLOW: 3- BEDROOMS Q 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **RE—USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD T9Tv 472 S.F. 349 GPD Permit valid for REPAIR OF SEPTIC SY ' EM ONLY, due It state and Local aepticWE-e4rian• 500 GAL. LEACHING CHAMBERS ACME OR EQUAL Board of Health review and approval is ,�.-e��?�• ( ) any future additions/renovations/alteaWITI'-I' 40 3TONE ALL AROUND sewage facilities and/or structures/dwelling. Yarmouth 11calth Departmcr:t APPROVED MA A P&OV D DATE BOARD OF HEALTH Name ate TITLE 5 SITE PLAN OF DANIEL A. OJALA, P.E., P.L.S. 20 BAYRIDGE DRIVE YARMOUTI-IPORT, MA PREPARED FOR JOHN ADELIZZI DATE: DECEMBER 11, 2019 off 508-362-4541 I fax 508-362-9880 downcape.com dOWO cape enghleerifg, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 19-399 ADELIZZI.DWG