HomeMy WebLinkAboutReview Checklist 01 V)( TOWN OF YARMOUTH ./.e:73SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 33 Zone of Contribution: In Out_ Acreage Commercial: Residential: Street: . 3 a &Ay '4 -i1..J i?1- 3 Village: y�,.."0 L.,77-/ 1- e7.-* Floor Plan: #Bedrooms: Owner: PC4 tV7 C►A Dam kreN 5k1 Installer: -1/.s ec• - Address: f.go.s.A,e-- Phone: Sob x 6 Z - 23 7 Phone: Builder: Engineer: -5 -aie,efsot 5 i ti�Q,Qjwl Address: Phone: SD -3Q5 - 97p Phone: N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material,above water table Gi_U ` b 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: IZ: 5.Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands / 7. Septic tank minimum 10 ft from foundation, deck Var.: (SE"1' ,J( ( 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ,� ✓ 9.Leaching minimum 100 ft from wetlands Var.: , 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: "V 11.Tank/leaching minimum 10 ft from property line Var.: f 12. System meets all other setback requirements Var.: V 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: f/ 15. System not in top or subsoil(A,B horizons)or 5'removal 1,!,.. 16.Proposed contours are suitable ✓ 17. System meets slope requirements-min. 1/8", preferred V ' " 18. System meets breakout requirements PVC liner: Wall: 17 • 19. Specified tee sizes are proper, gas baffle on outlet tee tZ- 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal V 22. System adequately sized for its intended use 1." 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field V// 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size f 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet, under driveway/parking 30.Buoyancy calculations for tank/pump chamber ✓V/ 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓ 33.H-20 loading is subject to vehicular traffic, groundwater ✓ 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd ✓ 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: pae77 ///�)/fT 6/03/03