Loading...
HomeMy WebLinkAboutReview Checklist r TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 7 7 Lot ea Zone of Contribution: In /Out_ Acreage Commercial: Residential: t Street: 3 a 4.4-„i ex).--i,,�„ 4 G ci ,,� Village: SamEfc✓/r7C- Floor Plan: tO #Bedrooms: 3 Owner: E,,,-,,,iG K� Installer: C ,N ro{rn of 0 r�� .5'1---A,Gnfz,--. Address: ,. Phone: 773,F 3 0 y/o1 c Phone: Builder: Engineer: pq 4,,'0( 5 9-( 3-----7.-- Address: �„------ Phone: -7-,if/ 7 Phone: N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above hi point of road H.P.: Fnd: Var.: ,/ 5. Water line 10 ft from septic components Var.: / 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: E`X S\ ,v L V 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab /a / " ,. 0 9.Leaching minimum 100 ft from wetlands Var.: V 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11. Tank/leaching minimum 10 ft from property line Var.: is 12. System meets all other setback requirements Var.: ,� 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 1/4"preferred 18. System meets breakout requirements PVC liner: Wall: ✓/ ' 19. Specified tee sizes are proper, gas baffle on outlet tee isr 20. Sewage is under 10,000 gpd for parcel V 21.No garbage disposal vO� 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox 1/ 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field a 500 e. / c/4.6_,_, 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet, under driveway/parking 30.Buoyancy calculations for tank/pump chamber ✓ 31.Engineer to inspect and certify soils: wall: commercial: A .,k 32.Engineer/Registered Sanitarian and(and Surveyor stampOsignature 33.H-20 loading is subject to vehicular traffic, groundwater _ f 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37.Check area lots for groundwater/Label groundwater in Assessor's Map , V Plan reviewed by: Al: /� . �' 6,03/03