Blde-20-001900 Commonwealth of Official Use Only Permit No. BLDE-20-001900 gE7. Massachusetts BOARD OA FIRE PREVENT REGULATIONS Occupancy and Fee Checked PO if I — 11�.c31.3 [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/7/2019 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the a ectncal work sc . ed below. Location(Street&Number) 46 NICKERSON FARM WAY 'l-tAkeni Owner or Tenant Telephone No. Owner's Address . ._.__..__..._____ Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead ❑ Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd CI No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ in- ElNo.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Aliaksei A Kuharenka Licensee: Aliaksei A Kuharenka Signature LIC.NO.: 20711 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:564 W YARMOUTH RD,WEST YARMOUTH MA 026731456 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 C. -e__\-S ti /tj ) ej Commonwealth,of Mamachuaett.4 ffi ial Use O 1—=Ma— t c� Permit No. -I't00 �! .2 �7epartment of ire Serviced t E_ Occupancy and Fee Checked /50 �/ ,,;= BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: /o i—(f City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)46 Nickerson Farm Way, South Yarmouth, MA Owner or Tenant Alex Kuharenka Telephone No. Owner's Address same Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residence Utility Authorization No. Existing Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Wire 18 panel solar PV system, Enphase IQ7+ microinverters Completion of the followingiable may be waived by the Inspector of Wires. Total No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Tf Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA q' No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units rcik CINo.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and I— Initiating Devices � Q No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons Heat Pump Number Tons KW No.of Self-Contained v O o No.of Waste Disposers Totals: Detection/Alerting Devices („j , 1— ' Munici al A c_) Z No.of Dishwashers Space/Area Heating KW Local ElConne pion ❑ Other • HeatingAppliances Security Systems:* No.of Dryers pP KW No.of Devices or Equivalent Lim D C0 m No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to Start: (D-- f'.-- t( Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND 0 OTHER ❑ (Specify:) I certify, under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Coastal Light Electric LIC.NO.:20711-A Licensee: Alex Kuharenka Signature LIC.NO.: (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:508-274-9981 Address:46 Nickerson Farm Way, S. Yarmouth, MA 02664 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner ❑owner's agent. Owner/Agent PERMIT FEE:$ Signature Telephone No. Utility Service Solar PV System One-line Diagram 120/240v Address:46 Nickerson Farm Way, MA Owner: Kuharenka Date: 10/3/2019 1 of 2 Existing Utility meter On pedestal Meter Junction box Line tap for solar connection before service disconnect 3-#8 CU THWN in 3/4"LFNC conduit • Existing Main Breaker Panel, 120/240v Main solar PV system disconnect 1200amp 30amp 1 J 2pole 2pole ) To be grouped with service disconnect / 1 eTh — / Solar PV System PM /—� Exterior Unfused Disconnect 120/240v,60 amp max /'\ pm Utility Meter MA SMART Meter - Interior combiner panel Communication unit 120/240v,1 phase,4 wire, 15amp/2pole 20amp/2pole Reverse feed rated Envoy r1 p1 20amp/2pole pm System Output Peak:5.31 kW AC System Output Continuous:5.22 kW AC Circuit Circuit (18)QTY Enphase IQ7+ microinverters A B (18)QTY 360 Watts PV panels • Solar PV System One-line Diagram Address:46 Nickerson Farm Way, MA Owner: Kuharenka Date: 10/3/2019 2 of 2 Circuit A I 2,610 VA continuous Solar panel Solar panel #8 bare Cu#8 bare Cu i!!!!!1 i!!!■!1 #8 bare Cu I!!!!!1 — — — E!!!!!1 I!!!!!1 E!!!!!1 1!!!!!1 1!!!!!1 1!!!!!1 1!!!!!1 1!!!!!1 1!!!!!1 I!!!!!1 1!!!!!1 1!!!!!1 1!!!!!1 1!!!!!1 E!!!!!1 MOW E!!!!!1 1!!!!!1 1!!!!!1 1!!!!!! 1!!!!!1 1 Micro 1 Enphase Micro Enphase inverter ? IQ7+ inverter 1, I07+ 9 MICRO-INVERTERS — — J-box Enphase AC Interconnect Cable—2 x#12 AWG Circuit B j 2,610 VA continuous Solar panel Solar panel #8 bare Cu #8 bare Cu #8 bare Cu !!!!!■ swum UMW — — — ■!!!!! !!!!!■ ■!!!t! !!!!!■ !!!!!! ■!!!!■ ■!!!!■ ■!!!!■ ■!!!!■ 11111111111111111 !!!!!■ !!!!!! ■!!!!E1 ■!!!!! !!!!!■ !!!!!! ■!!!!■ !!!!!■ ■!!!!■ ■!!!!! Micro Enphase Micro Enphase inverter { IQ7+ inverter IQ7+ 9 MICRO-INVERTERS — — 1-box Enphase AC Interconnect Cable—2 x#12 AWG Data Sn:=e`t Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7 Micro" and Enphase IQ 7+Mticro- n 7+ dramatically simplify the installation process while achieving the highest system efficiency. i�:roinverterS Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ Battery'", and the Enphase Enlighten"M monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install %%% • Lightweight and simple • Faster installation with improved,lighter two-wire cabling• Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class ii double-insulated enclosure • UL listed Smart Grid Ready IPa • Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell modules. CERTIFIED suery us-cn E34le ENPHASE. To learn more about Enphase offerings,visit enphase.com Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W'-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current module;lso)" 15A. 15 A <. Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/ranger 240 V/ 208 V/ 240 V/ 208 V/` 211-264 V 188-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short Circuit fault current over 3 ryoles; 5,t Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' "" 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage ciasAClrt 111" 111 AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peek efficiency . 97.6% 97:6-° 97.5 973 CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connectortype(1Q7-60-2-US&1Q7P US 72-2-t1 ) M 4(or Amptternol H4 UTX with additional 0-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES communication , power line commurl atllon(PtC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/1EEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at httos://enohase,com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com EN PHAS E. 2019 Enphase Energy All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 20"932'