APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/7/2019
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the a ectncal work sc . ed below.
Location(Street&Number) 46 NICKERSON FARM WAY 'l-tAkeni
Owner or Tenant Telephone No.
Owner's Address . ._.__..__..._____
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead ❑ Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd CI No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ in- ElNo.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee
provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such
coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Aliaksei A Kuharenka
Licensee: Aliaksei A Kuharenka Signature LIC.NO.: 20711
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address:564 W YARMOUTH RD,WEST YARMOUTH MA 026731456 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE:$150.00
C. -e__\-S ti /tj ) ej
Commonwealth,of Mamachuaett.4 ffi ial Use O
1—=Ma— t c� Permit No.
-I't00
�! .2 �7epartment of ire Serviced
t E_ Occupancy and Fee Checked /50 �/
,,;= BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: /o i—(f
City or Town of: Yarmouth To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number)46 Nickerson Farm Way, South Yarmouth, MA
Owner or Tenant Alex Kuharenka Telephone No.
Owner's Address same
Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box)
Purpose of Building Residence Utility Authorization No.
Existing Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters
New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Wire 18 panel solar PV system, Enphase IQ7+ microinverters
Completion of the followingiable may be waived by the Inspector of Wires.
Total
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Tf
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
q' No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units rcik
CINo.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
I— Initiating Devices
� Q No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
Heat Pump Number Tons KW No.of Self-Contained
v O o No.of Waste Disposers Totals: Detection/Alerting Devices
(„j , 1— ' Munici al
A c_) Z No.of Dishwashers Space/Area Heating KW Local ElConne pion ❑ Other
• HeatingAppliances Security Systems:*
No.of Dryers pP KW No.of Devices or Equivalent
Lim D C0 m No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to Start: (D-- f'.-- t( Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND 0 OTHER ❑ (Specify:)
I certify, under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Coastal Light Electric LIC.NO.:20711-A
Licensee: Alex Kuharenka Signature LIC.NO.:
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:508-274-9981
Address:46 Nickerson Farm Way, S. Yarmouth, MA 02664 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner ❑owner's agent.
Owner/Agent PERMIT FEE:$
Signature Telephone No.
Utility Service Solar PV System One-line Diagram
120/240v Address:46 Nickerson Farm Way, MA
Owner: Kuharenka
Date: 10/3/2019
1 of 2
Existing Utility meter
On pedestal Meter
Junction box
Line tap for solar connection before
service disconnect
3-#8 CU THWN in 3/4"LFNC conduit
•
Existing Main Breaker Panel,
120/240v Main solar PV system disconnect
1200amp 30amp 1
J 2pole 2pole ) To be grouped with service
disconnect
/ 1 eTh
— / Solar PV System
PM /—� Exterior Unfused Disconnect
120/240v,60 amp max
/'\ pm
Utility
Meter MA SMART
Meter
- Interior combiner panel
Communication unit 120/240v,1 phase,4 wire,
15amp/2pole 20amp/2pole Reverse feed rated
Envoy r1 p1
20amp/2pole
pm
System Output Peak:5.31 kW AC
System Output Continuous:5.22 kW AC Circuit Circuit
(18)QTY Enphase IQ7+ microinverters A B
(18)QTY 360 Watts PV panels
• Solar PV System One-line Diagram
Address:46 Nickerson Farm Way, MA
Owner: Kuharenka
Date: 10/3/2019
2 of 2
Circuit A I
2,610 VA continuous
Solar panel Solar panel
#8 bare Cu#8 bare Cu i!!!!!1 i!!!■!1 #8 bare Cu
I!!!!!1 — — — E!!!!!1
I!!!!!1 E!!!!!1
1!!!!!1 1!!!!!1
1!!!!!1 1!!!!!1
1!!!!!1 1!!!!!1
I!!!!!1 1!!!!!1
1!!!!!1 1!!!!!1
1!!!!!1 E!!!!!1
MOW E!!!!!1
1!!!!!1 1!!!!!1
1!!!!!! 1!!!!!1
1
Micro 1 Enphase Micro Enphase
inverter ? IQ7+ inverter 1, I07+
9 MICRO-INVERTERS
— — J-box
Enphase AC Interconnect Cable—2 x#12 AWG
Circuit B
j 2,610 VA continuous
Solar panel Solar panel
#8 bare Cu #8 bare Cu
#8 bare Cu !!!!!■ swum
UMW — — — ■!!!!!
!!!!!■ ■!!!t!
!!!!!■ !!!!!!
■!!!!■ ■!!!!■
■!!!!■ ■!!!!■
11111111111111111
!!!!!■ !!!!!!
■!!!!E1 ■!!!!!
!!!!!■ !!!!!!
■!!!!■ !!!!!■
■!!!!■ ■!!!!!
Micro Enphase Micro Enphase
inverter { IQ7+ inverter IQ7+
9 MICRO-INVERTERS
— — 1-box
Enphase AC Interconnect Cable—2 x#12 AWG
Data Sn:=e`t
Enphase Microinverters
Region:AMERICAS
Enphase The high-powered smart grid-ready
Enphase IQ 7 Micro" and Enphase IQ 7+Mticro-
n 7+ dramatically simplify the installation process while
achieving the highest system efficiency.
i�:roinverterS
Part of the Enphase IQ System,the IQ 7 and
IQ 7+ Microinverters integrate with the Enphase
IQ Envoy", Enphase IQ Battery'", and the Enphase
Enlighten"M monitoring and analysis software.
IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power-on testing,
enabling Enphase to provide an industry-leading
warranty of up to 25 years.
Easy to Install
%%% • Lightweight and simple
• Faster installation with improved,lighter two-wire cabling• Built-in rapid shutdown compliant(NEC 2014&2017)
Productive and Reliable
• Optimized for high powered 60-cell and 72-cell*modules
• More than a million hours of testing
• Class ii double-insulated enclosure
• UL listed
Smart Grid Ready
IPa • Complies with advanced grid support,voltage and
frequency ride-through requirements
• Remotely updates to respond to changing
grid requirements
• Configurable for varying grid profiles
• Meets CA Rule 21 (UL 1741-SA)
*The IQ 7+Micro is required to support 72-cell modules.
CERTIFIED
suery us-cn
E34le ENPHASE.
To learn more about Enphase offerings,visit enphase.com
Enphase IQ 7 and IQ 7+ Microinverters
INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US
Commonly used module pairings' 235 W'-350 W+ 235 W-440 W+
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Maximum input DC voltage 48 V 60 V
Peak power tracking voltage 27 V-37 V 27 V-45 V
Operating range 16 V-48 V 16 V-60 V
Min/Max start voltage 22 V/48 V 22 V/60 V
Max DC short circuit current module;lso)" 15A. 15 A <.
Overvoltage class DC port II II
DC port backfeed current 0 A 0 A
PV array configuration 1 x 1 ungrounded array;No additional DC side protection required;
AC side protection requires max 20A per branch circuit
OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter
Peak output power 250 VA 295 VA
Maximum continuous output power 240 VA 290 VA
Nominal(L-L)voltage/ranger 240 V/ 208 V/ 240 V/ 208 V/`
211-264 V 188-229 V 211-264 V 183-229 V
Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V)
Nominal frequency 60 Hz 60 Hz
Extended frequency range 47-68 Hz 47-68 Hz
AC short Circuit fault current over 3 ryoles; 5,t Arms 5.8 Arms
Maximum units per 20 A(L-L)branch circuit' "" 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC)
Overvoltage ciasAClrt 111" 111
AC port backfeed current 0 A 0 A
Power factor setting 1.0 1.0
Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
Peek efficiency . 97.6% 97:6-° 97.5 973
CEC weighted efficiency 97.0% 97.0% 97.0% 97.0%
MECHANICAL DATA
Ambient temperature range -40°C to+65°C
Relative humidity range 4%to 100%(condensing)
Connectortype(1Q7-60-2-US&1Q7P US 72-2-t1 ) M 4(or Amptternol H4 UTX with additional 0-DCC-5 adapter)
Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket)
Weight 1.08 kg(2.38 Ibs)
Cooling Natural convection-No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure
Environmental category/UV exposure rating NEMA Type 6/outdoor
FEATURES
communication , power line commurl atllon(PtC)
Monitoring Enlighten Manager and MyEnlighten monitoring options.
Both options require installation of an Enphase IQ Envoy.
Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break
disconnect required by NEC 690.
Compliance CA Rule 21 (UL 1741-SA)
UL 62109-1,UL1741/1EEE1547,FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO.107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
and DC conductors,when installed according manufacturer's instructions.
1.No enforced DC/AC ratio.See the compatibility calculator at httos://enohase,com/en-us/support/module-compatibility.
2.Nominal voltage range can be extended beyond nominal if required by the utility.
3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
To learn more about Enphase offerings,visit enphase.com EN PHAS E.