HomeMy WebLinkAboutReview Checklist I TOWN OF YARMOUTH </(
• - �. _ _ '",--;00 SEWAGE PLAN REVIEW CHECKLIST
Iry
//, 4
Location: A.M. (or 2 Lot .146 Zone of Contribution: In .`e Out__ Acreage 26 7�r'
Commercial: Residential:_
Street: s../...„
Village: i7Floor Plan:
e• #Bedrooms:
,Owner:
./�� Installer: 7124
Address: Phone:
Phone:
Builder: Engineer: ).
Address: Phone:
Phone:
N/A NO
1.Required#of copies received
2. Date of soils exam and percolation test not older than 2 years �
3. 4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.:• Fnd: Var.: •�.- ---'
5. Water line 10 ft from septic components Var.: ....,-
6.Benchmark indicated and shown-NGVD if near wetlands ;,.-7/
fi 7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: ....------
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.:
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: moi/ c...-------
15.
-------15. System not in top or subsoil(A,B horizons)or 5'removal �/
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", Vs"preferred t-/
18. System meets breakout requirements PVC liner: Wall: • \-/
19. Specified tee sizes are proper, gas baffle on outlet tee L�
20. Sewage is under 10,000 gpd for parcel 1
21.No garbage disposal \-
22. System adequately sized for its intended use ,-.....---
23.Minimum 6"stone or compacted below tank and dbox k..
24.Manhole covers within 6"of grade,pump chamber cover to grade l--/.
25.Inspection port on plastic chambers/leach field ��
26.Electrical permit for pump chamber/Separate meter for duplexes .-...-----
27.
f27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ./''
28. Septic tank/pump chamber to be factory waterproofed ,/.
29.Vent provided if leaching below 3 feet,under driveway/parking . --..
30.Buoyancy calculations for tank/pump chamber /"--
31. Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signatureC)
33.H-20 loading is subject to vehicular traffic, groundwater ._.i _
34.Title V Application and permit fee, installer signature ��
35.Foundation footing min.2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd /
37. Check area lots for groundwater/Label groundwater in Assessor', Map c./
Plan reviewed by: CO6/03/03