HomeMy WebLinkAboutEngineered Plan - 2018LEGEND X 99.1 EXIST. SPOT ELEV. BATH -[99]- PROPOSED CONTOUR Scale: 1 "= 198.4] PROPOSED SPOT EL. ROOM TH1 20 30 40 50 FEET rh TEST HOLE_ -- - 2� SLOPE OF GROUND 6" CRUSHED UTILITY POLE MECHANICAL FIRE HYDRANT CALLING DIGSAFE (1-888-344-7233) AND NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING LIVING NOTES ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR SYSTEM PROFILE COMPARABLE MEANS FOR FUTURE LOCATION. 2. MUNICIPAL WATER IS EXISTING PROVIDE MIN. 20" DIAM. WATERTIGHT ,i PROVIDE INSPECTION PORTS TO 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. ACCESS COVERS TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) WITHIN 3" OF FINISH GRADE 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-12 TOP FOUND. EL. 9.8' )I \ 8.2' 5. PIPE JOINTS TO BE MADE WATERTIGHT. MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM8.9 PRECAST H-10 8.5 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE ZABEL A100 D CE RISERS TYP. , PRECAST H 10 WITH 310 CMR 15.000 TITLE 5. •' --_ - _- FILTER PRIOR _._ __ _ - - „ - _ _ ( ) 2 sb 7.2 RISERS (TYP.) NOT, 2 MIN. WALL 4..,nSCH40 PVC � _ A. TO P/C 2'0 THIC�NESS REQUIRED 1500 GAL H-10 s" MIN. SUMP I PIPES LEVEL 1ST 2' 8.07 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY * DUAL COMPARTMENT " A�'' 12" MIN• INT• DIM. OTHER PURPOSE. 7.3 f SEPTIC TANK 14 6.13' TEE 'a TEE 5.88' 10" 1000 GAL H-10 EE 7.68' 5.76 TEE PUMP CHAMBER o°oOg0,00, o WATERTEST D BOX 0,28' 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. GAS BAFFLE..,' SEE DETAIL �° 0000 FOR LEVELNESS 7.40' 9. COMPONENTS NOT TO BE BACKFILLED OR 880+ GAL. ; 440+ GAL. BELOW 7.89' 7.72' CONCEALED WITHOUT INSPECTION BY BOARD OF QUICK4 PLUS STANDARD LOW PROFILE UNITS HEALTH AND PERMISSION OBTAINED FROM BOARD ,000°°o000000000 00•o000 OF HEALTH. •000000000000000°00000000000000 0808080000°COO . _ , j °°°°°°°i,2„01o,, 000 0°°°° r_ „°„°„°„°0000°. ;, ,.. ,.• _•. •• .. :.. • �I OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 24' X 11.33' 000 08080808000000000°00000000000000000800080;L 4' LIQ LEVEL ACME OR EQUAL °0000000000000000000000 (NO STONE PROPOSED) SYSTEM DESIGN: i GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM DWELLING (EXISTING DUPLEX WITH 2 BEDROOMS EACH SIDE) DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 FIRST COMPARTMENT 440 GPD (1) = 440 SECOND COMPARTMENT 880 + 440 GPD = 1320 TOTAL USE A 1500 GAL. DUAL COMPARTMENT SEPTIC TANK AND A 1000 GAL. PUMP CHAMBER LEACHING: 4.73 SF/LF x 4' LENGTH = 18.92 SF PER QUICK4 PLUS STANDARD LP UNIT 440 GPD/0.74 GPD/SF = 595 SF LEACHING REQ'D 595 SF/18.92 SF/UNIT = 31.4 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (32) QUICK4 PLUS STANDARD LP UNITS "IN' -FIELD CONFIGURATION OF 4 ROWS OF 8 UNITS 32 UNITS x 18.92 SF/UNIT = 605 SF> 595 SF 605 SF (0.74) = 448 GPD (OK) APPROVED 9" COVER MA DATE BOARD OF HEALTH 2% MIN. SLOPE OVER SYSTEM 4" LOAM & SEED T.O.W. 8.5 \ I' 21"f E CAP STONE UNITS 1/2" x 5 1/4" 1 = WWW Fiberglass _IIL-II - I=11LI_II -- Pins AS- 5'MIN. 3.5' MAX. 6„ VARIES PEASTONE COARSE SAND BACKFILL AGAINST WALL 40 MIL LINER FROM TOP PEASTONE/WALL -� �• TO 12" BELOW GRADE KEYSTONE OR EQUAL RETAINING WALL UNITS 18"X8 SET WITH 1" BATTER PER ROW FIBERGLASS PINS REQ. 6"X30" Crushed Rock or Unreinforced Concrete Leveling Pad req. RETAINING WALL CROSS SECTION BUOYANCY CALCS: H-10 1000 GAL. PC WEIGHS 8240 LBS 2.2' x 8.5 x 4.83 X 62.4 = 5636 LBS UP (OK) 5 NOT TO SCALE LICE # 18-380 10 S O _77 O„ HE LOT AREA 10,000±SF � 12: U 1A•5 EXISTING DUPLEX jai DWELLING v� TO F = 9.8 i � � 6 G DIRT DRIVE G / o X G 10000 � 1 BENCHMARK: MAG NAIL SET =7.3' NAVD88 VARIANCES REQUESTED UNDER TITLE 5 AND YARMOUTH HEALTH REGULATIONS: 1b: REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 14.3') 1h: REDUCTION IN GROUNDWATER SEPARATION, 5' TO 4' TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 10-17-2018 PERC. RATE _ < 2 MIN/INCH PROP. WATERTIGHT COVER TO GRADE CLASS I SOILS ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE PROVIDE QUICK DISCONNECT FOR PUMP r -I ELEV. BUILDING. ALARM TO BE ON S, SEPARATE CIRCUIT FROM PUMP O" A LS 10YR 2/1INV. IN 5.76' �j NO LOW P�0 NTS 12 1n .,o.. n 1 /T I__ PRESSURE LINE -E`- . CAL. H-- . O s e 600 GAL.+ SLOPE TO DRAIN BACK TO' PC LS ALARM ON RESERVE FLOAT SWITCH 0.25" WEEP HOLES1OYR 5/6 3, SETTINGS: PUMP ON CHECK VALVE 24„ 4" WORKING RANGE 8 MYERS SRM 4 4„ SUBMERSIBLE 4/10 HP PUMP PUMP OFF 8" SYSTEM (OR EQUAL) C 000 000000 0 SIEVE C><__ 0000 0 0 0000 PUMP CHAMBER - Pel . v . . fir REPA11t 01 SEI' I tG SVS -FFM.! M MS REMOVAL OF UNS I BLE SOIL REQUh (NOT TO SCALE) ONLY. due to. State and Local selyti�: variances. OUND PERIMETER OF�EACHING FACILII WATERPROOF/WATERTIGHT hoard of Health review and approval +s requirecDfur G -W ADJ. DATA: 0 TO S;UITABLE/NSOF� LAYER. REPLACE any future additionslrcm++.+tio+is/ tltcrations f 1 OYR 7/4 WELL: MIW 29 nT CLEAN MED. 'AND TO MEET . ECIFIC 110NS OF'S1 CMR 15.255(3) ;r sewage t +cifties an<1lor sb•uctures/�lwetli++g• ZONE. A Y,a� moutll Heaft.h 1)ep'artnrerat ADJ: 1.9' AUG 2018 PROPOSED BLOCK RETAINING WALL 1 � � I-10 PROVIDE 120' OF 40 MIL LINER AT 5' OFF SAS IN 10 AREA SHOWN. TOP AT C° ELEV. 8.1', BOTTOM AT EL. 4.1't BATH ,,000,0008(,OOC„O,C,0000000008U[,O/,0(,000„0,00080. - - Scale: 1 "= 20' ROOM 10. CONTRACTOR SHALL BE RESPONSIBLE FOR 20 30 40 50 FEET BEDROOM 6" CRUSHED OR MECHANICAL 4' CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP /rr p C LIVING LIVING downcape.com COMPACTION. (15STO. (15 21 [2]) BEDROOM VERIFYING THE LOCATION OF ALL UNDERGROUND & �S �V�/"11- civil engineers OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02575 WORK. 2.5 4 ( %SLOPE MIN.) ( %SLOPE MIN.) 1 ( SLOPE) 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 32 PARCEL 124 PROFILE BE REMOVED BENEATH AND 5' AROUND THE _ -- -LOW - - - - - ...-------...._... --- -. _ ., _ _ - _. --- - D0nDncrn E rerwnEr_ rerEE 1TV _ _ �- F UUNDATION ` J I SEPTIC TANK S PUMP CHAMBER 1 5 , , lIVVVJILV VI\VVIVV ttfllLl\ LL. J.T D BOX 6 ��r+�.nllvv FACILITY 12. EXISTING LEACHING FACILITY SHALL BE PUMPED w�..v.� i� vvi E rnEv r rwEr\ r LVVv �VIVC F1C `CL AS SHOWN ON COMMUNITY PANEL - AND REMOVED OR PUMPED AND FILLED WITH CLEAN #25001 CO588J DATED 7/16/2014 *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL SAND. UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS SITE IS NOT LOCATED WITHIN A ZONE II PRIOR TO INSTALLING ANY PORTON OF SEPTIC SYSTEM 13. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. A SEPARATE ELECTRIC METER FOR PUMP ONLY SHALL BE INSTALLED SO OWNER'S CAN SPLIT COST. SYSTEM DESIGN: i GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM DWELLING (EXISTING DUPLEX WITH 2 BEDROOMS EACH SIDE) DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 FIRST COMPARTMENT 440 GPD (1) = 440 SECOND COMPARTMENT 880 + 440 GPD = 1320 TOTAL USE A 1500 GAL. DUAL COMPARTMENT SEPTIC TANK AND A 1000 GAL. PUMP CHAMBER LEACHING: 4.73 SF/LF x 4' LENGTH = 18.92 SF PER QUICK4 PLUS STANDARD LP UNIT 440 GPD/0.74 GPD/SF = 595 SF LEACHING REQ'D 595 SF/18.92 SF/UNIT = 31.4 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (32) QUICK4 PLUS STANDARD LP UNITS "IN' -FIELD CONFIGURATION OF 4 ROWS OF 8 UNITS 32 UNITS x 18.92 SF/UNIT = 605 SF> 595 SF 605 SF (0.74) = 448 GPD (OK) APPROVED 9" COVER MA DATE BOARD OF HEALTH 2% MIN. SLOPE OVER SYSTEM 4" LOAM & SEED T.O.W. 8.5 \ I' 21"f E CAP STONE UNITS 1/2" x 5 1/4" 1 = WWW Fiberglass _IIL-II - I=11LI_II -- Pins AS- 5'MIN. 3.5' MAX. 6„ VARIES PEASTONE COARSE SAND BACKFILL AGAINST WALL 40 MIL LINER FROM TOP PEASTONE/WALL -� �• TO 12" BELOW GRADE KEYSTONE OR EQUAL RETAINING WALL UNITS 18"X8 SET WITH 1" BATTER PER ROW FIBERGLASS PINS REQ. 6"X30" Crushed Rock or Unreinforced Concrete Leveling Pad req. RETAINING WALL CROSS SECTION BUOYANCY CALCS: H-10 1000 GAL. PC WEIGHS 8240 LBS 2.2' x 8.5 x 4.83 X 62.4 = 5636 LBS UP (OK) 5 NOT TO SCALE LICE # 18-380 10 S O _77 O„ HE LOT AREA 10,000±SF � 12: U 1A•5 EXISTING DUPLEX jai DWELLING v� TO F = 9.8 i � � 6 G DIRT DRIVE G / o X G 10000 � 1 BENCHMARK: MAG NAIL SET =7.3' NAVD88 VARIANCES REQUESTED UNDER TITLE 5 AND YARMOUTH HEALTH REGULATIONS: 1b: REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 14.3') 1h: REDUCTION IN GROUNDWATER SEPARATION, 5' TO 4' TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 10-17-2018 PERC. RATE _ < 2 MIN/INCH PROP. WATERTIGHT COVER TO GRADE CLASS I SOILS ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE PROVIDE QUICK DISCONNECT FOR PUMP r -I ELEV. BUILDING. ALARM TO BE ON S, SEPARATE CIRCUIT FROM PUMP O" A LS 10YR 2/1INV. IN 5.76' �j NO LOW P�0 NTS 12 1n .,o.. n 1 /T I__ PRESSURE LINE -E`- . CAL. H-- . O s e 600 GAL.+ SLOPE TO DRAIN BACK TO' PC LS ALARM ON RESERVE FLOAT SWITCH 0.25" WEEP HOLES1OYR 5/6 3, SETTINGS: PUMP ON CHECK VALVE 24„ 4" WORKING RANGE 8 MYERS SRM 4 4„ SUBMERSIBLE 4/10 HP PUMP PUMP OFF 8" SYSTEM (OR EQUAL) C 000 000000 0 SIEVE C><__ 0000 0 0 0000 PUMP CHAMBER - Pel . v . . fir REPA11t 01 SEI' I tG SVS -FFM.! M MS REMOVAL OF UNS I BLE SOIL REQUh (NOT TO SCALE) ONLY. due to. State and Local selyti�: variances. OUND PERIMETER OF�EACHING FACILII WATERPROOF/WATERTIGHT hoard of Health review and approval +s requirecDfur G -W ADJ. DATA: 0 TO S;UITABLE/NSOF� LAYER. REPLACE any future additionslrcm++.+tio+is/ tltcrations f 1 OYR 7/4 WELL: MIW 29 nT CLEAN MED. 'AND TO MEET . ECIFIC 110NS OF'S1 CMR 15.255(3) ;r sewage t +cifties an<1lor sb•uctures/�lwetli++g• ZONE. A Y,a� moutll Heaft.h 1)ep'artnrerat ADJ: 1.9' AUG 2018 PROPOSED BLOCK RETAINING WALL 1 � � I-10 PROVIDE 120' OF 40 MIL LINER AT 5' OFF SAS IN 10 AREA SHOWN. TOP AT C° ELEV. 8.1', BOTTOM AT EL. 4.1't FLOOR PLAN NOT TO SCALE OF rF t �.Ii OFm'- ry "� ! 4SSq " DANIEL DANIELA. ti A, < o OJALA C1JaLA CIVIL f Nd,t0 . ] \ IS C d R� i-2�~r�SS�ONE n DATE DANIEL A. OJALA, P.E., P.L.S. i AN T' I T � � L Z 5 S�7= PL OF U`%TLAND DRIVE -- 'If"% W T Y A" M T H M1 A ?I U U PREPARED FOR 01W6 I m 1-4 Z5 T OLP"A Folff y T I I DATE: BATH BATH Scale: 1 "= 20' ROOM ROOM 20 30 40 50 FEET BEDROOM BEDROOM KITCHEN KITCHEN I fax 508-362-9880 LIVING LIVING downcape.com BEDROOM ROOM ROOM BEDROOM FLOOR PLAN NOT TO SCALE OF rF t �.Ii OFm'- ry "� ! 4SSq " DANIEL DANIELA. ti A, < o OJALA C1JaLA CIVIL f Nd,t0 . ] \ IS C d R� i-2�~r�SS�ONE n DATE DANIEL A. OJALA, P.E., P.L.S. i AN T' I T � � L Z 5 S�7= PL OF U`%TLAND DRIVE -- 'If"% W T Y A" M T H M1 A ?I U U PREPARED FOR 01W6 I m 1-4 Z5 T OLP"A Folff y T I I DATE: OCTOBER 24, 2018 Scale: 1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcape.com 10W!1 CQPa e/I&ffl/I1e@f//1 . 111C. civil engineers land surveyors MAY 14 2019 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02575 HEALTH DEPT. 18-380 MARTIN.DWG