Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 11 Lot Zone of Contribution: In Out X Acreage . 3 7 Commercial: Residential: J\ Street: J f 4- Z1-- Village: -'-Village: So liatindh Floor Plan: #Bedrooms: 3 Owner: Irl -6W p{ 4 Installer: A-44 -i k.p_4(-* Address: S6019 yyl f. Phone: q-D$- 7 IL, - ('tp,0 Phone: q g _on'-7 . 7D 2 g Builder: Engineer: S W Z2-/${Y End//1 f ell Gf Address: Phone: SDS- -3 F' -v(p7SO tI Phone: N/A YES/ NO 1.Required#of copies received ✓ 2.Date of soils exam and percolation test not older than 2 years N , 3.4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: iO 6.Benchmark indicated and shown-NGVD if near wetlands a.--- - 7. /7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ✓ 9.Leaching minimum 100 ft from wetlands Var.: ,/ 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t/ 11. Tank/leaching minimum 10 ft from property line Var.: _t ./ 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 1/ 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5'removal i/--- 16. /16.Proposed contours are suitable I/ 17. System meets slope requirements-min. 1/8", Vs"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 2)..No garbage disposal 22. System adequately sized for its intended use -./ 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade +/'' 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes t/ 27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size )./ 28. Septic tank/pump chamber to be factory waterproofed t< 29.Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber N/ 31. Engineer to inspect and certify soils: wall: commercial: v, 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater `/ 34. Title V Application and permit fee, installer signature y 35.Foundation footing min.2 feet above adjusted ground water for new house / 36.Deed Restriction required max. #bedrooms: max. flow: gpd_ 37.Check area lots for groundwater/Label oundwat- •I Assessor's Map Plan reviewed by: al l 6/03iO3