Loading...
HomeMy WebLinkAboutEngineered Plans - 2020---64 --- EXISTING CONTOUR t x 60.98 EXISTING SPOT GRADE _ —W— EXISTING WATER SVC. -- EXISTING GAS SERVICE ? --BN.4i-- OVERHEAD WIRES '/"N / r f 4owh etlI , b'ere TEST PIT , BENCHMARK h ,, l ' 3 ' � 't^ ` PK SET le9895 LEGEND >� 97.90 iy WIMBLEDON DRIVEL LOC UQSSMAP ''. 100.38 x 100.94 % N 47'58'50", f x 1 43 /O GENERAL NOTES: 6sUP N Lf -1 Tyl 33A s7.00' 10029 �IN �l' 0 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL (aF REt'tatR OF 4I-1 1lC h! � f g.°:1 / BOARD OF HEALTH AND THE DESIGN ENGINEER. Permlt valid 4351.4. due ti, state and Local I.tw vatiau. ctti 6d�%pQ�S .^ SH�LL x / 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS itua€d of ticetsh rceievr and appra,. 1 _, rcqu lu, i n DRIVEWAY _ t "' dt OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE rtt tn;.,sc a¢3diiionslreno3 atio t r, r:ntue4 to r 5c 1001 r 0o" LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: xxaKe farslatics aml,4ir structures "' -310 CMR 15.405(1)(b): -�/ 1) A 1' variance to the 3' maximum cover requirement, for up to Varnt<4utb ttea&th 1Tep.��rmozat 4' of max. cover. S.A.S. shall be H-20 and vented. i9 99 ill APP Cad' �` � ' . ON 10 � 58 3. THE SEWAGE D SPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE °Hi"E 9985 x BOARD OF HEALTH AND THE X10021 DESIGN ENGINEER. _ 98,16 ,� 2 nL7 A V ! EXISTING ! + �� �� 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN '/ HOUSE(#40j A ENGINEER BEFORE CONSTRUCTION CONTINUES. trate Natae. �. .. �TO.F. 100.1 O- ro /� 0 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. / / P0 �= o' o 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF f��'� SHED�� / �3 TP -1 O O _ 1J::.18 , x HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. rn j/, , 102 1 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. BENCHMARK m 100.U4 fence , THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. STOOP/COR j PATIO 99.99 PEASTONEcrL 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS EL. =100.77 it, _, PATIO " AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE 9983 '100b7m DIRECTED BY THE APPROVING AUTHORITIES. 99'52'.' m 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY SPIKE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING EXISANG SEPTIC TANK v 6 o CONSTRUCTION. — (TO REMAIN) r,. TOP OF TANK, EL.=97.571 '` - 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR .'{0029 INV(OUT)=96.241 + i 1 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 1�76 ^ 12. AREAS REQUIRING STR':�POUT OF UNSUITABLE MATERIALS SHALL BE BAMBOO GARDEN 3-L�.' INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND fence .001.fence - -- IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. of dtgs9 S 47'58'50" wPARCEL ID: 30-309 q�yG VENT STRlPOUT BOUNDARY ��P� o PETER T. s ExisnNc s.A.s. sT!PouT CONTAMINATED salts AssoaA.TE° PROPOSED SEPTIC SYSTEM UPGRADE PLAN McENTEE (FROM RECORD AS -BUILT) WITH THE EXISTING S.A.S. (SEE NOTE 11) No.CIVIL 35109 TO BE REMOVED 40 WIMBLEDON DRIVE, WEST YARMOUTH, MA Ll/l RF0/STERN� Prepared for: Cape Cod Septic Services, 350 Main St., W. Falmouth, MA 02673 OWNER OF RECOED Engineering by: SCALE DRAWN JOB. NO. - RODRIGUES, GEORGE Engineering Works, Inc. 1"=20' P.T.M. 307-19 � 817 ORONOCO STREET 12 West Crossfield Rood, Forestdale, MA 02644 DATE CHECKED SHEET NO. 1 ALEXANDRIA VA 11214 (508) 477-5313 1/3/20 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, FINAL GRADE SHALL NOT BE AT, OR BELOW, EL.=96.25 FOR A DISTANCE OF 15' FROM THE EDGE SEPTIC TANK PROPOSED D-BOX OF THE PROPOSED S.A.S. INSTALL RISERS & COVERS OVER INLET & INSTALL A.. RISER & WATERTGrT PROPOSED S.S ,m OUTLET AND SET TO 6' OF FINISH GRADE COVER SET TO 6" OF GRADE INSTALL RISER & COVER OVER ONE CHAMBER (MIN.) AND SET TO WITHIN 3" OF FINISH GRADE TO SERVE T.O.F.=100.6± AS AN INSPECTION MANHOLE. F.G. EL=100.21 F.G. EL. 99.51 F.G. EL.=100.1± F.G. EL.=100.0± CHARCOAL VENT '',LOF=100.61 ® S=1% (MIN.) - " 4"SCH40 PVC .. @ S-1% (MIN.) 4 SCH40 PVC SHED s -2" LAYF�R Of 1 8" ®O ® N g 88' 01 s Mr TO 1/2 DOUBLE rn S < 12" WASHED STONE A), EXISTING 48' LIQUID OR APPROVED FILTER FABRIC) U, LEVEL AD 3.5' 3' 3.5' N BAFFLE INV.=96.08 PROPOSED INV.=95.91 3/4"-1 1/2"GAS INV.=96.24± 991i INV.=95.75 EFFECTIVE WIDTH = 10 DOUBLE WASHED EXISTING STONE T EXISTING SEPTIC TANK W 5 LC-6 LEACHING CHAMBERS IN SERIES WITH 3.5' OF DOUBLE WASHED STONE-ALL AROUND i PROPOSED S.A.S. 37 I`�-.1 NOTES: H-20 RATED TOP CONC. ELEV.=96.58 1) CONTRACTOR IFY ALL PIPE LL -BREAKOUT PRIOR TO INSTALLATONtXISTING INV. ELEV.=95.75 ®®®O®®® ELEV.=96.25 VIM S.A.S. LAYOUT 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ®®®®®®® ON A MECHANICALLY COMPACTED STABLE BASE OR BOTTOM ELEV.=94.75 SIX INCH AGGREGATE BASE, AS SPECIFIED IN 310 3.5' 5 x 6' = 30' 3.5' CMR 15.221(2). 4' OF NATURALLY OCCURRING 3) INSTALL INLET & OUTLET TEES AS REQUIRED. PERVIOUS MATERIAL EFFECTIVE LENGTH = 37' 5' (MIN.) ABOVE G.W. _1- �_ _ _ _ _ _ - {; KNOCKOUT" 4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE LEACHING SYSTEM SECTION W`cv�x I AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. ADJUSTED G.W., EL=89.75 - I SEPTIC SYSTEM PROFILE {-xNocKaur4'KN DIJTI M 0 N.T.S. {'KNOCKam J DESIGN CRITERIA SOIL LOG 72. PLAN VIEW NUMBER OF BEDROOMS: 3 BEDROOMS DATE: JANUARYSOIL EVALUATOR: PETER McENTEE PE(SE#1542) TEXTURAL CLASS: CLASS I WITNESS: BRUCE MURPHY R.S. HEALTH AGENTDESIGN _SOIL 3 U PERCOLATION RATE: <2 MIN/IN ELEV. TP-1 DEPTH ELEv. TP-2 DEPTH 0„ 0" 72.TI 12- INVERR ;E2L2 DAILY FLOW: 330 G.P.D. 100.3 100.1 A DESIGN FLOW: 330 G.P.D. I FILL LOAMY SAND 10YR 4/2 -j - -j GARBAGE GRINDER: NO-not allowed w'tn design f 99 1 993 C 2 80AMY 1 PERC 36 SIDE VIEW END VIEW SAND LEACHING AREA REQUIRED: (330) = 445.9 S.F. 10YR 5/4 6"/24" WIGGIN LC-6, OR EQUAL, H-20 LOADING 74 EXISTING SEPTIC TANK: GALLON CAPACITY MEQ. SAND 96.1 G 46" 2.5Y s/s LEACHING CHAMBER PROPOSED D-BOX: 1 INLET, LET, 3 OUTLETS, H-10 RATED 42 X60" MED SAND 2.5Y 6/4 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 95.1 USE 5 LC-6 LEACHING CHAMBERS IN SERIES WITH 60" 3.5' OF DOUBLE WASHED STONE-ALL AROUND NO EXCAVATOR ACCESS 89.75 STDG. TO BACK YARD. DUG 40 WIMBLEDON DRIVE, WEST YARMOUTH, MA GW - - TO DETERMINE "B""HORIZON ORIZON Prepared for: Cape Cod Septic Services, 350 Main St., W. Falmouth, MA 02673 SID'EWALL AREA: (10.0' + 37.0') x 2 x 1' = 94.0 SF 89.05 STDG. GW _ 135" DEPTH & PERC RATE "B" BOTTOM AREA: 10.0' x 37.0' = 370.0 SF 68.8 PERC RATE: <2 MIN/IN HORIZON 138" Engineering by: SCALE DRAWN J06. N0. TOTAL AREA: ...................464.0 SF / PERC RATE <2 MIN/IN "C" HORIZON / Engineering Works, Inc. N.T.S. P.T.M. 307-19 DATE CHECKED SHEET N0. STANDING GW AT 135" (EL.=89.1) 12 West Crossfield Rood, Forestdole, MA 02644 DESIGN FLOW PROVIDED: 0.74 GPD/SF(464.0 SF) = 343.4 GPD INDEX WELL, MIW-29, ZONE A, ADJUSTMENT=0.75', DEC 2019 (508) 477-5313 1/3/20 P.T.M. 2 of 2