Loading...
HomeMy WebLinkAboutReview Checklist t--- -o 7 7 Zov TOWN OF YARMOUTH // /�6f_ )))."'� • SEWAGE PLAN REVIEW CHECKLIST - t/ /-1, f $ Location: A.M. & Lot � Zone of Contribution: In Out Acreage � C ` `� ' le2 - Commercial: Residential: t�� Street: ` Cl Village: - 4,l✓, Floor Plan: #Bedrooms: Owner: 4/yew zw / % % Installer: 7 /4.d- r-ial-- ,a-, . Address: Phone * 7 - Phone: 'e:'f 1 AO di‘/SA-C- 137 � J/ 71 L , Builder: Engineer: �l/ ' �/„ Address: Phone: --' , 1. - 6 7?ti--(-7 Phone: ,L4/`4/x, i ,e lic/i / , „ir, 2z1,, YES ; NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years c/ 3.4-5 ft of naturally occurring pervious material,above water table / 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L/ 5.Water line 10 ft from septic components Var.: _/ 6.Benchmark indicated and shown-NGVD if near wetlands (-/- 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: °�, ..1------ 9.Leaching minimum 100 ft from wetlands Var.: <--/?-----� 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: k.---/ 12. System meets all other setback requirements Var.: d.,__ -" 13.Uses adjustment for maximum high groundwater Var.: /- 14.Leaching set 4-5 ft above adj.water or botto tesole Var.: tom' 15. System not in top or subsoil(A,B horizons) r 5'remov'l c't.:5---- 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '/4" ferrel , c4k 18. System meets breakout requirements KPVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel L._------ =21.No garbage disposal L/5 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox l.,,/ • 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field L./ 26.Electrical permit for pump chamber/Separate meter for duplexes L--s 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size �/ 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking C 30.Buoyancy calculations for tank/pump chamber �/` 31.Engineer to inspect and certify soils: wall: commercial: �/ y 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature �•_ 33.H-20 loading is subject to vehicular traffic, groundwater ...._.----- 34. _i34.Title V Application and permit fee, installer signature (`) 35.Foundation footing min. 2 feet above adjusted ground water for new house �_� 36.Deed Restriction required max. #bedrooms:---2/max. flow: -- �v' gpd 1/4....------ 37.Check area lots for groundwater/Label groundwater in Assessor's Map `----- Plan reviewed by: at. 6/03/03