Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 60 Lot ? Zone of Contribution: In Out /Acreage Commercial: Residential: f Street: . 7 , 0, 0- L i ft K. Village: aztSt y am- Floor Plan: V #Bedrooms: Owner «ie7 Installer: A'4,-/- 64,/.03- �h� Address: Phone: 5.0g- _398- c:25 ' Phone: Builder'. Engineer: pew? Address: / Phone: •5,N3 3G .- *# 7.-// . Phone: N/A YES ' NO 1.Required#of copies received ✓ 2.Date of soils exam and percolation test not older than 2 years V , 3.4-5 ft of naturally occurring pervious material,above water table V7 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: ,/ 6.Benchmark indicated and shown=NGVD if near wetlands ✓, 7.Septic tank minimum 10 ft from foundation,deck Var.: V 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: j2./ft, Ver. sir, C) 9.Leaching minimum 100 ft from wetlands Var.: J. 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ./ 11.Tank/leaching minimum 10 ft from property line Var.: 12.System meets all other setback requirements Var.: Y 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15.System not in top or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable ✓ 17. System meets slope requirements-min. 1/8", 1/e"pref • V 18.System meets breakout requirements VC liner: Wall: ,� 19. Specified tee sizes are proper,gas baffle on outlet tee ,/ 20.Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox V/ 24.Manhole covers within 6"of grade,pump chamber cover to grade ✓ 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes V 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size y 28.Septic tank/pump chamber to be factory waterproofed V 29.Vent provided if leaching below 3 feet,under driveway/parking V 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: ✓ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature .7 33.H-20 loading is subject to vehicular traffic, groundwater ✓ k/ 34.Title V Application and permit fee,installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 17, 36.Deed Restriction required max. #bedrooms: max. flow: gpd V/ 37.Check area lots for groundwater/Label groundwater in A essor's Map / Plan reviewed by: p,ix &l/l 1 1 1 1 L(I t l /03