HomeMy WebLinkAboutEngineered Plan - 2019TOP FOUND. EL. 13.3' PRECAST H-10 RISERS (TYP.) 2'0 r ��* 10.8' SYSTEM PROFILE (NOT TO SCALE) • PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 12.2' MINIMUM .75' OF COVER OVER PRECAST 90' ELBOW - 4"0SCH40 PVC 6" MIN. SUMP PIPES LEVEL 1ST 2' 12" MIN. INT. DIM. 1 11/ 2500 GAL 10 SEPTIC TANK/ 10.15' TEE PUMP CHAMBER'• COMBINATION 010;0;0;0;0;° SEE DETAIL BELOW 12.74' ISX00000000000000000000000000006 0000000000000 000000000000000000000000000000000000000000000 ":0000,0�0_0„n.q.� 0 0 o 0 o (..�_�_0_n_o.o 0 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) (_2L.5% SLOPE) FOUNDATION 26' SEPTIC TANK > 27' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99}-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 0 TEST HOLE 25 SLOPE OF GROUND CT13 UTILITY POLE v FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNF'gO,• PHIL RENAUD . DATE: 12/11/2019 PERC. RATE _ < 2 MIN/INCH CLASS • I SOILS 1z ELEV. 0,9 4 13' S 12" 1OYR 4/2 B LS 229) 1OYR 5/6 11.2' C PERC MS G -W ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 1.3' NOVEMBER 2019 108" 1OYR 7/6 4' GROUNDWATER ENCOUNTERED AT 90" EL. 5.5' DICE # 19-401 WATERTEST D'BOX FOR LEVELNESS .--,p 2.47', (-Z-% SLOPE) D' BOX 5' - MARK CORNERS OF LEACHING FIELD W/ REBAR SET 4" BELOW GRADE FILTER FABRIC 13.6 TOP 12.82' 4" 8" NOTES 1. DATUM IS NAVD 88 PROVIDE INSPECTION PORTS TO 2. MUNICIPAL WATER IS EXISTING WITHIN 3" OF FINISH GRADE 2% SLOPE 3. MINIMUM PIPE PITCH TO BE 1/8' PER F )OT. y \ 4. DESIGN LOADING FOR ALL PROPOSED PF�=CAST FINISHED GRADE- a LOAM & SEED OR PAVE AS REQ. UNITS TO BE AASHO H -LQ L CLEAN FILL ERFORAIED PMC X O.C. S=0.005 0 0 3/4"-1-1/2" DOUBLE WASHED O STONE LEACHING FIELD LEVEL BOTTOM 0 LEACHING FACILITY BUOYANCY CALC: 2500 H-10 TANK WEIGHT: 22,560 LBS 12.0 x 6.5 x 2.4 x 62.4 = 11,682 UP (OK) OF 40 MIL LINER AT 5' ffA SHOWN. TOP AT 30.TTOM AT EL. 8.8't Scale:1 "= 20' 0 10 20 30 40 50 FEET 30.0' 11.80' 5.0' J ADJUSTED GROUNDWATER 6.8' FLOOR PLAN 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCOI ;DANCE WITH 310 CMR 15.000 (TITLE 5.) 6"DEPTH MIN BELOW INV. 7. THIS PLAN IS FOR PROPOSED WORK ONI.Y AND NOT TO BE USED FOR LOT LINE STAKING C R ANY L12.30 OTHER PURPOSE. ` 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40- •" PVC. 9. COMPONENTS NOT TO BE BACKFILLED O t CONCEALED. WITHOUT INSPECTION BY BOARI 1 OF HEALTH AND PERMISSION OBTAINED FROM �,lOARD OF HEALTH. I - 10. CONTRACTOR SHALL BE RESPONSIBLE f OR ,_ t'II" TEE CALLING DIGSAFE (1-888-344-7233) AND VERIFYING LOCUS MAP THE LOCATION OF ALL UNDERGROUND & OIERHEAD -SLOPE TO DRAIN BACK 2. UTILITIES PRIOR TO COMMENCEMENT OF WO K I; SCALE 1 "=2000'f 11. ANY UNSUITABLE MATERIAL ENCOUNTEF =D SHALL BE REMOVED BENEATH AND 5' AROUND TH = ASSESSORS MAP 40 PARCEL 48 5" WORKINGURANGMP PROPOSED LEACHING FACILITY. r - MIN. 100 GAL. THIS SI )E CHECK VALVE MYERS SRM 4 LOCUS IS WITHIN FEMA FLOOD ZONE X AS PORCH 12. EXISTING LEACHING FACILITY SHALL BEIPUMPED SHOWN ON COMMUNITY PANEL #25001CO588J "LE AND REMOVED OR PUMPED AND FILLED WI1 H CLEAN SAND. DATED 7/16/2014 PUMP OFF 12" 13. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITADLE FOR PUMP CONNECTION. ELECTRI :AL PERMIT SYSTEM DESIGN: REQUIRED. PUMP ACCESS FOR ROUTINE MAINTENANCE CAST IRON MUST BE PROVIDED FOR ZABEL FILTER. COVERS TO GRADE COV INSTALLER MUST FOLLOW ALL - 567 GAL. RESERVE' MANUFACTURER'S SPECIFICATIONS FOR ONI,V, due to State and local septic variances. Board of Health re,iew and approval is required for PROVIDE QUICK DISCONNECT FOR PUMP PROPER FILTER INSTALLATION any future add:ttms/renovationsf:+Iterations to ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE sewage facilrtie. nn,l,or structures/d�%clling. BUILDING: ALARM TO BE ON INV. IN 10.15' -I Yat moath Ilealth Depariment NO LOW POINTS SEPARATE CIRCUIT FROM PUMP ZABEL FILTER USE A 2500 GAL. DUAL COMPARTMENT SEPTIC TANK/ PUMP CHAABER 2" PRESSURE LINE FLOAT SWITCH ALARM ON - (A100) OUTLET TEE W/EXTENSION SETTINGS:N ,_ t'II" TEE _ __ -SLOPE TO DRAIN BACK OE 11 0.25" WEEP HOLES 5" WORKINGURANGMP 6" r - MIN. 100 GAL. THIS SI )E CHECK VALVE MYERS SRM 4 5.. OF BAF "LE SUBMERSIBLE 4/10 HP PUMP PUMP OFF 12" SYSTEM (OR EQUAL) 2500 GAL. SEPjFIC TANK/ s" BAFFLE SYSTEM DESIGN: PUMP CHAMBEF COMBINATION GARBAGE DISPOSER IS NOT ALLOWED (NOT TO ',SCALE) - Permit valid for REPAIR OF SEPTIC SYSTEM DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD ONI,V, due to State and local septic variances. Board of Health re,iew and approval is required for USE A 330 GPD DESIGN FLOW any future add:ttms/renovationsf:+Iterations to sewage facilrtie. nn,l,or structures/d�%clling. SEPTIC TANK: 330 GPD (2) = 660 Yat moath Ilealth Depariment Al'i ROV ED USE A 2500 GAL. DUAL COMPARTMENT SEPTIC TANK/ PUMP CHAABER LEACHING: 330 GPD / (.74) = 446 SF REQUIRED Naerte Date SF 50 TITLE 5 SITE PLAN 450 SFX .74 33Oc D OK USE A 15' X 30' PIPE AND STONE LEACHING FIELD OF #15 HONEYSUCKLE WAY YARMOUTH, MA MA PREPARED FOR APPROVED DATE BOARD OF HEALTH E; STATE OF LETTY RUSSO .A&A,4..._ . . �A-rye. DATE DANIEL A. OJALA, P.E., P.L.S. DATE: DEC. 20, 2019 off 508-362-4541 I fox 508-362-9880 downcope.com 40MI 41pe 07 ;#70eM74gs inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 19-401