Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Blde-20-000835
'. or ( (v Commonwealth of Official Use Only Permit No. BLDE-20-000835 -.� � Massachusetts BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date•8/13/2019 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to nertorm the electrical work described lu ln•• Location(Street&Number) 2 SHEFFIELD RD Owner or Tenant NEVES RUYTER Telephone No. Owner's Address NEVES JOSEILDES S,2 SHEFFIELD ROAD,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service 100 Amps 120/24( Volts Overhead ❑ Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of roof mounted photovoltaic solar systems,22 panels Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: 09/13/2019 Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: LLOYD R SMITH Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST,MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) ❑ owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 9 «(I74 (9 pURISD1CTIONAL-NOTES: - — GOVERNING CODES— ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1. 2015 INTERNATIONAL RESIDENTIAL CODE 2. 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION a. 2017 NATIONAL ELECTRICAL CODE b. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: PV 0.0-COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS _ GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: _ ' ` f�' "r;1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING . - -:' - MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED THE ROCK-IT SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE .. - -, , i+''r, SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SPACED AS SHOWN IN THE DETAILS,AND MUST BE STAGGERED TO iJ 4' • - THE ROOF SURFACE. ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b. UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SHALL BEs"LAG r " CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2X"PENETRATION INTO ROOF FRAMING. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE C. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 'a �. _ RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD-20 psi TYPICAL,0 psf UNDER NEW PV SYSTEM. V` �'. 1' INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCEe. GROUND SNOW LOAD=30 psi ,,,, VOLTAGE. I. WIND SPEED=140 mph ( ' ,, .,•.Ir•� SEE"E 1.0 AND'E 2.0 FOR DIAGRAMS,CALCULATIONS,SCHEDULE AND g. EXPOSURE CATEGORY=B " V i Vint.S o I a r .`` I 4•. SPECIFICATIONS. 1800 ASHTON BLVD.LEHI,UT,84043 , ". " 1.877.404.4129 �" I° '' MA LICENSE: HIC-170848, 7 ` ME-15688A,SS-002342 ,......,-1 - PHOTOVOLTAIC SYSTEM SPECIFICATIONS: NEVES RESIDENCE '+ s2 SHEFFIELD RD r it . m„J ' Y SYSTEM SIZE-7.040kW DC I7.600kW AC WEST YARMOUTH,MA 02673-1437 r r * MODULE TYPE&AMOUNT-(22)Jinko Solar JKM320M-60HBL WITH 22 SolarEdge P320 OPTIMIZERS ` UTILITY ACCOUNT*1430 665 0036 J " '} .,'' MODULE DIMENSIONS-(LIWIH)65.55"I 39.45"/1.38" It `tit ., ', e `. '' INVERTER-(1)SolarEdge Technologies SE7600H-US000BNC4 SERVICE t REGIONAL \ y` �,,., % ,, , _ --r"' INTERCONNECTION METHOD-SUPPLY TAP OPERATING CENTER:MA-03 COVER i \ .l— ,0 ---- DATE:8/52019 DRAWN BY:CHRISLUKE SHEET PV STRING(S): SYSTEM LEGEND 1 SLOPE-40 El #1)11MODULES AZIMUTH-174.17 PV ------------- -------_--- MATERIAL- PV SYSTEM SIZE: ® #2)11 MODULES COMPOSITION SHINGLE NEW 7.040kW DC 7.600kW AC I�EXISTING INTERIOR MAIN SERVICE PANEL POINT n OF WTERCONNECTION TIED TO UTILITY METER #2283225. 0 NEW SMART PRODUCTION METER.LOCATED WITHIN 10'OF MSP. ® NEW PV SYSTEM AC DISCONNECT. LOCATED WITHIN 10'OF MSP. I P n I 1 NEW PV SYSTEM INVERTER SolarEdge Technologies SE7600H-U0000BNC4(RSD EQUIPPED) 0 J 22 NEW JINKO SOLAR JKM320MEOHBL MODULES. SOL AR SOR EDGE P320 OPTIMIZERS,MOUNTED 0 ON THE BACK OF EACH MODULE. NEW PV CONDUIT RUN.'SEE EE1.0 CONDUIT SCHEDULE —_—__EXTERIOR RUN ------- -=ATTIC RUN X NEW JUNCTION BOX.(MOUNTED WITH SOLADECK( n EXISTING UTILITY METER. 6 2283225 J \\ 4.> °I11°. °11>i///,/' °I1'\ //, M o vivint.Solar O0 1.877.404.4129 _. 2 SHEFFIELD RD NEVES RESIDENCE 2 SHEFFIELD RD WEST YARMOUTH,MA,02673-1437 FRONT OF HOUSE. UTILITY ACCOUNT#:1430 865 0036 —' -------------J SITE PLAN REGNAL BE0964z9 REGIONAL OPERATING CENTER:MA-03 PV 1 .0 DATE:81512019 -- SCALE:1/4"=I-0" DRAWN BY:CHRIS LUKE MOUNTING LEGEND ROCK-IT COUPLING MID CLAMP ROCK-IT D MP alk MI CLAMP O T1111 I ROCK-IT 3.0 COUPLING '_ MID CLAMP \ ROCK-IT _1—T ROCK-IT SLIDE / \ PEDESTAL METAL ROCK-IT 5/16'x3/8- '•'— FLASHING ® COUPLING SHELF HEX FLANGE BOLT ,' 300 SERIES SS ROCK-IT COUPLING SHELF '� COMP SHINGLES `1 f �T���� ISOMETRIC VIEW \\j \ SS LAG SCREW = 1 (-�1 TORDUE=I JE2 FT-LBS. NI ,�\\ ow SIDE VIEW 6/16'x1 1/2" TIE PLATE HEX FLANGE BOLT B ILSCO SGB-4 GROUNDING LUGS SIDE VIEW 300 SERIES SS 0 O t ROCK-IT MOUNT DETAIL s 1 0 .o..O..EE S 1.0 NOT TOEUALE U.L.LISTING FOR EGOFASTEN.2/03 2 'OCK-IT COUPLING ASSEMBLY wl WEIGHT'.2J6. s 1.0 NOT TO SGLE TOP VIEW / CLAMP t ATTACHMENT CLAMP•ATTACHMENT _ PERMITTED COUPLING " ~ CANTLEVER L13 OR LESS COUPLING I I CLAMP SPACING •NDSCAPE=MAX 48'(4'-0') COUPLING PORC AMPMAX 48'(4'-0") I"'I I"'! RAFTER MODULE IIIIIII ROCK-IT SLIDE _= MODULE I"1II„'I METAL r T T T T T T MODULE FLASHING I FORMSM BONDED WASHER I' A () �' I I I( II RAFTER 1111 RAFTER WATERTIGHT SEAL A 1 A A • ,, RAFTER I u I I=LANFACAPF CJ AMP SPACING 2'x6"AT 16.O.C. '.i 4 PV SYSTEM MOUNTING DETAIL 5 MODULES IN PORTRAIT/LANDSCAPE L=PORTRAIT 51.0 N....... 51.0 NOT TOSCA�LE CLAMP SPACING COMP SHINGLES 1 21/2 MN 3"MIN AND 6'MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE Fig ONE HOLE STEEL STRAP CONDUIT �_ ___—_.._._....-._.__-_. I MIN 5/16"DIAM —x SS LAG SCREW 1./� PV MODULE,TYP.MOUNT Allh TOROUE-13E2 FT-CBS. TO FRAMING OF EXISTING ~ ROOF TYPE,PARALLEL . 1_4\ z vivint.Solar WITH PLANE OF ROOF CONDUIT MOUNT BRACKET 6'MAXIMU _ - 1.877.404.4129 ZNIM-1 SECTION VIEW ' ' 112- \ '�FLASHING OR TILE STRAP1 — — — NEVES RESIDENCE wAVIVIVIA W ITI2A AWOlTeLlrifte tri3 n:�t'L2,LwevwRmras.L. ,ITT,{G+ 2 SHEFFIELD RD WEST YARMOUTH,MA,02673-1437 3 SECTION VIEW UTILITY ACCOUNT#:1430 865 0036 , s 1.0 NOT TO SCALE 6 PV ARRAY TYP.ELEVATION 2 CONDUIT MOUNTING DETAIL NOL TOSCME NOT TO SCALE ---- --5 1.0 5 L0 SERVICE#:S-6098429 1 REGIONAL S 1.O MOUNT DETAILS OPERATING CENTER MA-03 _ DATE:8/5/2019 ---------------- - SCALE:NOT TO SCALE AWN BY:CHRIS LUKE Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shall be Copper) DC System Size(Watts) 6930 Tag Description Wire Gauge 8 of Conductors/Color Conduit Type Conduit Size e w rn AC System Size(Watts) 7600 1 PV Output(PV Wire) 10 AWG 2(V.,V-) Free Air N/A m o Total Module Count 22 1 EGC(Bare Copper Ground) 6 AWG 1 BARE Free Air N/A - O i.ci 0 — C N 00 2 Inverter Input(THWN-2) 12 AWG 4(2Vo,2V-)B/R EMT 1/2" z o O m Q 2 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" y = 2 a 3 Inverter Output(THWN-2) 8 AWG 30.1,12,N)B/R/W EMT 3/4" Z LL ,t, c 3 EGC(THWN-2) 8AWG 1(GRN) EMT 3/4" y ,iz '0 8 4 Service Feeder(THWN-2) 6 AWG 3(11,L2,N)B/R/W EMT 3/4" -o ru E a 4 GEC(THWN-2) 8AWG 1(GRN) EMT 3/4" o > m 4.: C m • ♦ N O N N U 01 N a g a SolarEdge S W 5E7600H-US 0in rii '" "Conforms to ANSI I— m C12.1-2008 PV System SMART Meter Z O_ Point of Interconnec6 on,Supply Side Rapid Shutdown Murray LCOO2GS 705.12(A) Z n Disconnect,Square D 240V/60A Breaker Box,or w w Z m DU222RB 240V/60A equivalent.with 75°C iJ mn Unfused,NEMA3,with 75' terminations Existing 240V/100A N J m C terminations Service Panel,Single Z Z �/ Phase,with 100A Main STRING 2:11 PV 0 © 11 __ _ SHEET MODULES Disconnect W/OPTIMIZERS . ...° t ( NAME.■ ,l([-�,� r�� /yam, LINEC`� V11 'YYli. WIL —� • _ STRING 1:11 PV 0 © 11 \ 100A I 01 MODULES NEMA 4 Junction Box I o-d LO M `^ • M C W/OPTIMIZERS . .°°° 1 • n �A n SHEET �,,,yyy��� Y Y NUMBER: PI V C/ z ------_ T — t - } —T 0 22 PV MODULES PER INVERTER=6930 WAITS Visible/Lnckable'Knife'AC Minimum DEC size 6 1 v4 57C Disconnect AWG copper W PV Module Rating @ STC Conductor Calculations m u Module Make/Model Jinko Solar JKM315M-60HBL c m 8 Wire gauge calculated from code art.310.15(B)(16)with ambient temperature calculations from a w g3 Max.Power-Point Current(Imp) 9.49 Amps art.310.15(B)(2)(a). v z 8n m Max.Power-Point Voltage(Vmp) 33.2 Volts For"On Roof"conductors we use the 90°C column ampacity,the relevant ambient temperature re o a rrnn Open-Circuit Voltage(Voc) 40.7 Volts adjustment,and raceway fill adjustments from 310.15(B)(16).Conduit shall be installed at least > LL f ^ Optimizer SolarEdge P320 Short-Circuit Current(Isc) 10.04 Amps 1"above the roof deck. Si w 5 DC Input Power 320 Watts Max.Series Fuse(OCPD) 20 Amps For"Off Roof"conductors we use the 75°C column ampacity,or the 90°C column ampacity with g ,=i, 0 8 DC Max.Input Voltage 48_Volts Nom.Max.Power at SIC(Pmax) 315 Watts the relevant ambient temperature and raceway fill adjustments,whichever is less. v , E N T DC Max.Input Current 13.75 Amps Max.System Voltage 1000 VDC(UL/IEc) The rating of the conductor after adjustments MUST be greater than,or equal to,the continuous g DC Max.Output Current 15 Amps Voc Temperature Coefficient -0.28 I %/C duty uprated output current. 5 Max.string rating inverter dependent.See SE documents. Calculation Example-Wire Rating(90°C)x Ambient Temperature Adjustment s Conduit Fill Inverter Make/Model SolarEdge SE7600H-US AC Output Current According to art,690.8(B)(1) 32 Amps Adjustment>=Continuous Duty Output Current (Tag 2 On Roof): CEC Efficiency 99 % Nominal AC Voltage 240 Volts Inverter Input:12 AWG rated 30 A, 30 A x 1 x 0.8=24 A>=18.75 A AC Operating Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) (Tag 3 Off Roof): Cont.Max Output Current 32 Amps Inverter Output:8 AWG rated 50 A, 50 A>=40 A _. DC Max Input Current 20 Amps Rooftop conductor ampacities designed in compliance with art. (Tag 4 Off Roof): Input Short Circuit Current 45 Amps 690.8,Tables 310.15(B)(2)(a),310.15(B)(3)(a),310.15(B)(3)(c), Service Feeder:6 AWG rated 65 A, 65 A>=60 A Max Output Fault Current 40 A/20 ms 310.15(B)(16),Chapter 9 Table 4,5,&9. Location specific temperature obtained from ASHRAE 2017 data tables. ASHRAE 2017-BARNSTABLE MUNICIPAL • ti Highest Monthly 2%D.B.Design Temp.:29.5°C N Lowest Min.Mean Extreme D.B.:-19.2°C • o v 5 A 2 u cn OCPD Calculations 8 Breakers sized according to continuous duty output current.PV circuit nominal current based off cc r- inverter continuous output current X(1.25[art.690.8(A))). 0 K N L. fel Inverter 1:SE7600H-US Max Output=32 A x 1.25[art.690.8(A)] > .20— =40A<=40A(OCPD) system output current w/continuous duty=40<=40A(System OCPD) W cc v, = m J V N N N Q O, Other Notes Z `O •Designed according to and all code citations are relevant to the 2017 National Electrical Code. SHEET •All interior raceways carrying DC current shall be metallic. NAME: N +� v m 2 a SHEET NUMBER: eV W Conduit,Raceways,and 1-Boxes(Labeled Every 10')Per Plaques and Directories at the Service Equipment(MSP)and the SE7600H-US String 1 DC Disconnecting Means Per 690.53 c m 8 690.31(G)(3)&(4) Location of All System Disconnects Per 690.56(B)&705.10 PHOTOVOLTAIC DC POWER SOURCE DISCONNECT v o ,tOO m WARNING:PHOTOVOLTAIC POWER SOURCE C#,UTION: STRING 1 z -- c m POWER TO THIS BUILDI IS ALSO SURRLIED FROM TOE MAXIMUM VOLTAGE: 400 V w = f FOLLOWING SOURCWITH DISCONNETS LOCATE!?AS MAXIMUM CURRENT: 15 A y LL .d.5 c OUsleutti e6gettaa[Adinl�fdpbarNfiMettldnne1/290.64 -----— .SHOWN -a DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A Z = o 'o PHOTOVOLTAIC AC POWER SOURCE w ut RATED AC OUTPUT CURRENT:32 A �: A7 - c eV Ei NOM.OPERATING AC VOLTAGE:240 V `' '�' y( METER A}(D MAIN SE♦1VICE SE7600H-US String 2 DC Disconnecting Means Per 690.53 0 /��'.'�j I AC DI,SCbN�ff���CT '— �� PHOTOVOLTAIC DC POWER SOURCE DISCONNECT PV System Disconnects Per 690.13(B) _ INVER7�R STRING 2 PV SYSTEM DISCONNECT �,��� ` �-i*� MAXIMUM VOLTAGE: 400 V MAXIMUM CURRENT: 15 A All Disconnecting Means Per 690.13(B)&690.15(D) DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: 15 A WARNING PV With Rapid Shutdown,Installed Within 3 ft of the Service ELECTRICAL SHOCK HAZARD Disconnecting Means Per 690.56(C)(1)(a) TERMINALS ON THE LINE AND SIDES MAY BE ENERGIZED IN THE OPEN POSITION SOLAR P+• SYSTEM EQW D • m �F Power Source Output Connection,Adjacent to Back- MTH RPM ,Y • 0, fed Breaker Per705.12 _- v • WARNING o9, POWER SOURCE OUTPUT CONNECTION TURN RAPID SHUTDOWN DO NOT RELOCATE THIS OVERCURRENT SWITCH TO THE DEVICE "OFF"POSITION TO SHUTDOWN PV SYSTEM u AND REDUCE Rapid Shutdown Switch Per 690.56(C)(3) SHOCK HAZARD MI O, IN ARRAY .`�, RAPID SHUTDOWN SWITCH FOR e SOLAR PV SYSTEM o e 5 o 8 m 5 g .^i Z " i K N J W Z Np .1Q J p O Z I Z 8 SHEET NAME: m C N C N 2 to 332 SHEET NUMBER: ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED. En ALL PLACARDS SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE. Iai MAIN BREAKER DE-RATED TO*•*DUE TO SOLAR (� PHOTOVOLTAIC AC POWER SOURCE (� PHOTOVOLTAIC DC POWER SOURCE DISCONNECT tO , �AAF � m CIRCUITS \J RATED AC OUTPUT CURRENT:*•*A J MAXIMUM VOLTAGE: ""A ***-value calculated for each m $ MAX OF***AMPS PV SOURCE ALLOWED NOM,OPERATING AC VOLTAGE:*'*V MAXIMUM CURRENT: ***V account,for specific value see the v ,^o DO NOT INCREASE MAIN BREAKER RATING Property of Vivint Solar DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: •*'A previous warning label page s o o m Property of Vivint Solar ( .- Property of Vivint Solar a ti WARNING 5 WARNING:PHOTOVOLTAIC POWER SOURCE d th w t �/ Property of Vivint Solar �C� SITE PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE Z th o a ELECTRICAL SHOCK HAZARD y TERMINALS ON THE LINE AND LOAD SIDES MAY BE AND DISCONNECT LOCATIONS.PLACARD SHALL BE -o N E Q ENERGIZED IN THE OPEN POSITION 6 POWER SOURCtEOUrTPUT CONNECTION MOUNTED ON EXTERIOR OF ELECTRICAL PANEL .o y Property of Vivint Solar �J DO NOT RELOCATE THIS OVERCURRENT DEVICE Property of Vivint Solar PV SYSTEM DISCONNECT Property of Vivint Solar i 1 Property of Vivint Solar ///// 10 PV rapid shutdown label required by RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM �--.) 690.56(C)(1)indicated on E.3 Property of Vivint Solar f: C• cn N • O V U IF APPLICABLE m ROOFTOP ARRAY 7 INSIDE PANEL 4115 INSIDE PANEL 0 0 a g a EVERY 10'AND • G, ? s T 2 3 O O IF APPLICABLE cc O yOsPOGZ O ti PO�.F 0 IF APPLICABLE ,^ w kJ, O,r,.��FL Z m o M Z DC ww � O W N 5 DISCONNECT $ \ INSIDE . i E _ _- _——. — —— _—_ SHEET s. SOLAR INVERTERS COMBINER PANEL VISIBLE/LOCKABLE VIVINT SOLAR METER VISIBLE/LOCKABLE SUB PANEL MAIN SERVICE NAME: (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL m JUNCTION O INTEGRATED WITH (WHERE REQUIRED) 4 Box ARRAY) TYPICAL SOLAR GENERATION INSTALLATION m 3 t (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) SHEET ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC)CONDUIT,ENCLOSURES, NUMBER: BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND RACE-WAYS,CABLE ASSEMBLIES,JUNCTION BOXES COMBINER BOXES,AND DISCONNECTS TO ALERT THE FIRE HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED.ALL PLACARDS SERVICE TO AVOID CUTTING THEM.MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT(3048 MM),ABOVE SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS.HANDWRITTEN SIGNS WILL AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR BARRIERS. a NOT BE ACCEPTABLE. LLI