HomeMy WebLinkAboutEngineered Plan - 2019T.O.F. EL.= 35.7'±
FINISH GRADE
@ FND. EL.= 34.9'+
4:
HCA
HC -2
i
28.1'
30.1'
FINISH GRADE OVER D -BOX = 34.7'+
15.6'
FINISH GRADE OVER CHAMBERS 33.7' - 34.2'
CORNER OF STONE (3)
GENERAL .OT E
45.4'
CORNER OF STONE (4)
34.3'
49.9'
CSE
12.
3/4TO 1-1/2DOUBLE WASHED
PROVIDE EXTENSION RISER
REMOVABLE WATER -TIGHT COVER OVER
EVALUATOR:
SLOPE @ 2% MIN. OVER SYSTEM
STONE TO CROWN OF PIPE
1, UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION
WITH COVER OVER INLET &
RISER TO WITHIN 6" OF FINISHED GRADE
4" SCHEDULE 40 PVC
INSPECTION PORT WITH ACCESS
„ „ „
2 OF 1/8 TO 1/2 DOUBLE WASHED
METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL
OUTLET TO WITHIN 6" OF F.G.
F.G. OVER TANK EL. = 34,6'±
4
5" DIA. OUTLETS)
°
MIN SLOPE 1 /o
BOX TO F.G. (SEE NOTE 21)
S TONE OR GEOTEXTILE FILTER FABRIC
CODE AND ANY APPLICABLE LOCAL RULES.
2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE
T
} PLACE RISERS ON ALL DE IG
S N ENGINEE
TOP OF SAS =31.23' CHAMBERS WITH 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL
PROPOSED4".
EXISTING 4 $CH, 40 PVC 36" MAX. 30,40' 36" MAX. t INLET PIPES TO 6" OF SYSTEM UNLESS OTHERWISE NOTED.
SEvvER rii c BREAKOUT EL = 30.90 FINISHED GRADE
SEWER PIPE I 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN
-1
3".DROP MAX I IL=89'± ELEVATION = 30.90' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A
- 6 3 2" DROP MIN . 3„ 9 PROVIDE WATERTIGHT
o S.A.S. AND THE TOP OF
-- T FIVE FEET FROM
- ---- _ - o IS PLACE LEAS
_ RANE LINER
MIN. SLOPE @ 1%
o I GEOMEMB
JOINTS (TYP.) o
FN' 4" PVC IN FROM o THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION.
0
1.7± SEPTIC TANK 4" PVC OUT TO 0 0 0 O 0 0 0 0 0 0 0 O o
CONTRACTOR TO PROVIDE I 14 3. C) 00 i o 5. SLOPE ALL SOLID PIPE AT 1.0%MINIMUM.
O LEACHING FACILITY o o 0 0 0
SPECIFIED DROP BETWEEN I oo 00
LL , 12" 6" , 2' o0 0 0 . o I o 0 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL.
INLET AND OUTLET CONTRACTOR CONTRACTOR SHA OUT ET TEE 30.70 MIN. 30.53 0 D D CD D 0 0 j
SHALL VERIFY SIZE 48 VERIFY CONDITION OF 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK
AND CONDITION OF EXISTING TEES GASBAFFLE6" CRUSHED STONE i0 CI 0000 0� 0 0 o FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS
EXISTING SEPTIC AND REPLACE AS { OVER MECHANICALLY o o _ NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH
AND DESIGN ENGINEER.
40
TANK NECESSARY I
COMPACTED BASE ' I �
5 8.5' (TYP) 4.0 .4.0'.
4.83' 4 0 8. ELEVATIONS BASED ON APPROXIMATE MEAN SEA LEVEL DATUM. BENCHMARK 1
OUTLET. DISTRIBUTION BOX
TO BE INSTALLED ON A LEVEL STABLE 25.0' - (TYP.) ELEVATION OF 35.00' ESTABLISHED ON TOP OF CBDH, AND BENCHMARK 2 ELEVATION OF
BASE. FIRST TWO FEET OF OUTLET , GROUND WATER ELEV.=. 22.50' I 35.4T ESTABLISHED ON THE LOWER CORNER STEP AS SHOWN ON PLAN.
12.83'
PIPES TO BE LAID LEVEL. 28'40 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION
I 5' MIN. REQUIRED -/CHAMBER END VIEW THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT
EXISTING 1,000 GALLON CONCRETE SEPTIC TANK 2 - 500 GALLON CHAMBERS
CROSS SECTION VIEW TYPICAL CHAMBER PROFILE 1 -888 -DIG -SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES
r_• a -U-e ^>> t t r- _ ! a�' _ s � m -o m I %_i � L a � ®� - � �-�- t�_ e t � � t� 1� � � -- � TO THE DESIGN ENGINEER.
_ _ m • s
-' ._ I I^
i % �ta.a l r°'is �f lei 1 dlL I I �� L��Bv I..%E� 1 d� Y1 L:
ELEVATION PRIOR TO ANY WORK & LJ -_ _ _ � _ _ _
NOTIFY ENGINEER IF DEFERENT. NOT TO SCALE NOT TO SCALE
NOT TO SCALE I� _ _. _...
10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT.
TEST PIT 4)ATA �11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING � SWING -TIES F ,...� fl
REGULATIONS OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM
DESCRIPTION
HCA
HC -2
CORNER OF STONE (1)
28.1'
30.1'
CORNER OF STONE (2)
15.6'
21.8'
CORNER OF STONE (3)
25.1'
45.4'
CORNER OF STONE (4)
34.3'
49.9'
MAP 89�;{ ELEV WATER < 22.50' \�\G REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY,
1 ` , ` P. it ` =
LOT 85 _ -�- I � -.,� ��� � ..;�� FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3).
/ PERC RATE _ < 2 min./inchUND
Op! 15. THOSE SHOWN RI ORO CONTINUATION OF WORK.
T OF ANY DISCREPANCIES FO
ZONE II SITE CONDITIONS FROMIN
pp. ••3`t � ,-_ .., `�;. DEPTH OF PERC = 30" - 48"
0
d)3' 2� i� y.. r"_ \ _� 16. PROPOSED PROJECT IS LOCATED WITHIN:
S6 // Y f TEXTURAL CLASS: 1
o ,N P fit t+
N / c r - !� ASSESSOR'S MAP 89 LOT 84
OWNER OF RECORD: JUDITH L. PAQUIN
Z s t LOCUS ' , O"
50'
a.S -�" rt , , , A y ADDRESS: 1 AVERY LANE
33
-/- \ GA . Loam Sand
Pl cA \ t J t r 10Yr 411
1611 32.17' SOUTH YARMOUTH, MA 02664
GPj� li lO, a ;�
GPsr11 B Loamy Sand FEMA FLOOD ZONE X
GPS' \ o ; �' 1 / _'i7� 10Yr5/8
COMMUNITY PANEL# 25001 C0587
X 30"
,1 _ -- � �' - � yi 31.00' 17. DEED REFERENCE: L.C. CERTIFICATE # 143815
_ O �� �+•: � ,., ,, � �,;. ti
SHED t < 'o - I y L.. , ? Perc
18. PLAN REFERENCE: L.C. PLAN # 31209-D
/ 8 Yarmouth Dennis 1 4 48" 29.50'
1t n t 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION.
/ y� -y High Sch
o Reglona
j` 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE;USED ONLY
f
t `"-� `� ` ` 1 �� FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY
\ / O , nor ' { 1 L > ` FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE
�\ TOF=35.7 ± Gj, Medium Sal�d
`' t'! I T' C 2.5Y 6/6I 21. A 4" PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TO A
f. _..
DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3 OF FINISH GRADE. A
EXISTING (2) FLOW DIFFUSERS 0`S �O
I O REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS.
�
PER SEPTIC AS -BUILT ON FILE � I\
\ MAP 89 �, 22. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL
DATED 2-10-97 LOT 84.
O,� LOCUS PLAN- REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT.
\ �
(TO BE ABANDONED) \ `'A `x / \ 13,184 ± S.F. -o
°' y „ _ ,
\ #1 \ L SCALE: 1 - 1000
I EXISTING I M� 132" 22.50'
\ LP 2 -BEDROOM ' R`2 No Mottling, Standing or Weeping Observed
EXISTING LEACHING PIT PER \ t DWELLING I �'
SEPTIC AS -BUILT ON FILE '\ ���'c
7 PATIO -Jo D I G N DATA
LEGEND
DATED 2-10-97
(TO BE PUMPED, FILLED WITH ` I \ NUMBER OF BEDROOMS (EXISTING) 2 50x0' EXISTING SPOT GRADE
CLEAN SAND AND ABANDONED) ? i' 34x3' c''
\ \ � � NUMBER OF BEDROOMS (DESIGN) 3 (MIN. PER TITLE 5) i - - - 50 - - - EXISTING CONTOUR
DESIGN FLOW 110 GAUDAY/BEDROOM
• -Z50 - PROPOSED CONTOUR
`\ RE �R / / QPJ�O TOTAL DESIGN FLOW 330 GAUDAY
- r 50 PROPOSED SPOT GRADE
EXISTING 1,000 GALLON ��
STEPS / DESIGN FLOW x 200 % 660 GAUDAY
SEPTIC TANK TO BE USED IN 12" PROPOSED TWO (2) GAS EXISTING GAS LINE
THIS DESIGN Eh I USE EXISTING 1,000 GALLON SEPTIC TANK
- 500 j
Permit valid for REPAIR OF SEPTIC Sk',1FNl
ONLY, due to state and Local septic val,.,,,,es,
of
anyrdfuture Health
uldit"n
tns/renovationa��,, , is i t""nst for
swage facilities ,Pit/or structures/d%s, (t ',;;.
yarwouth Health Dui-
APPP4,01'i I
�Z� 2o2L
Na Date
CHAMBERS E�T�C EXISTING UNDERGROUND UTILITIES
GARAGE\ j W W . EXISTING WATER LINE
MAP 89 ���� \<` / I PROPOSED / INSTALL 2 - 500 GAL. CHAMBERS w/AGGREGATE DEC 0 9 ZOi�
�'�-' , DISTRIBUTION BOX 34x3' / \\ i TEST PIT LOCATION
006' j - HC -1 ` SIDEWALL CAPACITY
HEALTH DE^ T.
LOT 83 �
3) 71P (LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0.74 GPD/S.F.) GAUDAY -' EXISTING 1,000 GALLON SEPTIC TANK
PROPOSED (25.01+12.83')(2) (21) ( 0.74 GPD/ S.F.) =112.0 GAUDAY
Benchmark 2 - _� - 3�`/ / INSPECTION PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE
Lower Cnr. StepBOTTOM CAPACITY
gq .: PORT
HC -2
Elev. = 35.47 ����� (2) 34x9'
20 TP1 d
Approx. MSL ¢ M (LENGTH x WIDTH) (0.74 GPD/S.F.) = GAUDAY
10" i 33x5 PROPOSED DISTRIBUTION BOX
i , \\ (25.0'x 12.83') (0.74 GPD/S.F.)' = 237.4 GAUDAY
PROPOSED 500 GALLON LEACHING CHAMBER
STUMP0 14"
22" \
N i 4 -z TOTALS:
00
...:. Y
z REV. DATE TOTAL NUMBER OF CHAMBERS 2 j
B APP'D. DESCRIPTION
'U TOTAL LEACHING AREA 472.2 SQ.FT.
< SHRUBJ TOTAL LEACHING CAPACITY 349.4 GAL./DAY PROPOSED SEPTIC SYSTEM UPGRADE
\ OF
PREPARED FOR:
7\ ,. MORSGs
y�T
o I\ JOHN L. a CAPEWIDE ENTERPRISES
�h0 QL CHURCHILL JR. it;
N0.48066 c
`� i o °� o �� LOCATED AT
a y \ 16„
'". Q o.. STUMP 10" ° g L 1 AVERY LANE
Ag
NOTES: Benchmark 1 �- °� 34x1' GAs GP l SOUTH YARMOUTH, MA 02664
Top CBDH < GAS
�_ GAS 35 I
1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF Elev. = 35.00' �. w m N83,26'0() „E AS GAS / ` I SCALE: ' 1 INCH = 10 FT. DATE: DECEMBER 3, 2019
EACH SEPTIC SYSTEM COMPONENT. Approx. MSL 63.98, GAS GAs G
2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE L
GAS OF 0 5 10 20 40 FEET
�.
PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT .\' x 4 ' GAS JOHN L ���, PREPARED BY:
DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF CB/DH ELEC. -�''INC.
HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. 0 HA ,DHOLE
RESERVED FOR BOARD OF HEALTH USE CHURCHILL JR. N JC ENGINEERING, INC
UT Box No: 418072854 CRANBERRY HIGHWAY
3.) ENTIRE PROPERTY IS LOCATED WITHIN A DEP APPROVED ZONE II. Y STREET ct EAST WAREHAM, MA 02538
D ONLY ASA COURTESY - BARN" P NATE �YOUT)
4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDE O
FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS SITE.
� T (40� VVI�E 50$.273.0377
IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL S I 1 PLAN
Drawn By: ATB Designed By: ATB Checked By: MCP JOB No. 4929
NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT. I SCALE: 1" = 10'
w.
"���
r/APPROPRIATE
r r) ��
1 . ,1 :, r
4�
PERC NO.
NIA
Phil Renaud, RS
AUTHORITY.
r -ALL
INSPECTOR:
CSE
12.
SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED
EVALUATOR:
Michael Pimentel, EIT,
UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR
C.S.E. APPROVAL DATE:, Oct. 1999
TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING.
4
`
November21, 2019
T
@ 0
„#a
'" �'
DATE:
13.
DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES.
¢v
r 06. e
ZONE 11
z-
r
`
+
TEST PIT#:
ELEV TOP =
1
33.50'
14.
WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE
MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY.
MAP 89�;{ ELEV WATER < 22.50' \�\G REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY,
1 ` , ` P. it ` =
LOT 85 _ -�- I � -.,� ��� � ..;�� FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3).
/ PERC RATE _ < 2 min./inchUND
Op! 15. THOSE SHOWN RI ORO CONTINUATION OF WORK.
T OF ANY DISCREPANCIES FO
ZONE II SITE CONDITIONS FROMIN
pp. ••3`t � ,-_ .., `�;. DEPTH OF PERC = 30" - 48"
0
d)3' 2� i� y.. r"_ \ _� 16. PROPOSED PROJECT IS LOCATED WITHIN:
S6 // Y f TEXTURAL CLASS: 1
o ,N P fit t+
N / c r - !� ASSESSOR'S MAP 89 LOT 84
OWNER OF RECORD: JUDITH L. PAQUIN
Z s t LOCUS ' , O"
50'
a.S -�" rt , , , A y ADDRESS: 1 AVERY LANE
33
-/- \ GA . Loam Sand
Pl cA \ t J t r 10Yr 411
1611 32.17' SOUTH YARMOUTH, MA 02664
GPj� li lO, a ;�
GPsr11 B Loamy Sand FEMA FLOOD ZONE X
GPS' \ o ; �' 1 / _'i7� 10Yr5/8
COMMUNITY PANEL# 25001 C0587
X 30"
,1 _ -- � �' - � yi 31.00' 17. DEED REFERENCE: L.C. CERTIFICATE # 143815
_ O �� �+•: � ,., ,, � �,;. ti
SHED t < 'o - I y L.. , ? Perc
18. PLAN REFERENCE: L.C. PLAN # 31209-D
/ 8 Yarmouth Dennis 1 4 48" 29.50'
1t n t 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION.
/ y� -y High Sch
o Reglona
j` 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE;USED ONLY
f
t `"-� `� ` ` 1 �� FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY
\ / O , nor ' { 1 L > ` FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE
�\ TOF=35.7 ± Gj, Medium Sal�d
`' t'! I T' C 2.5Y 6/6I 21. A 4" PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TO A
f. _..
DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3 OF FINISH GRADE. A
EXISTING (2) FLOW DIFFUSERS 0`S �O
I O REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS.
�
PER SEPTIC AS -BUILT ON FILE � I\
\ MAP 89 �, 22. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL
DATED 2-10-97 LOT 84.
O,� LOCUS PLAN- REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT.
\ �
(TO BE ABANDONED) \ `'A `x / \ 13,184 ± S.F. -o
°' y „ _ ,
\ #1 \ L SCALE: 1 - 1000
I EXISTING I M� 132" 22.50'
\ LP 2 -BEDROOM ' R`2 No Mottling, Standing or Weeping Observed
EXISTING LEACHING PIT PER \ t DWELLING I �'
SEPTIC AS -BUILT ON FILE '\ ���'c
7 PATIO -Jo D I G N DATA
LEGEND
DATED 2-10-97
(TO BE PUMPED, FILLED WITH ` I \ NUMBER OF BEDROOMS (EXISTING) 2 50x0' EXISTING SPOT GRADE
CLEAN SAND AND ABANDONED) ? i' 34x3' c''
\ \ � � NUMBER OF BEDROOMS (DESIGN) 3 (MIN. PER TITLE 5) i - - - 50 - - - EXISTING CONTOUR
DESIGN FLOW 110 GAUDAY/BEDROOM
• -Z50 - PROPOSED CONTOUR
`\ RE �R / / QPJ�O TOTAL DESIGN FLOW 330 GAUDAY
- r 50 PROPOSED SPOT GRADE
EXISTING 1,000 GALLON ��
STEPS / DESIGN FLOW x 200 % 660 GAUDAY
SEPTIC TANK TO BE USED IN 12" PROPOSED TWO (2) GAS EXISTING GAS LINE
THIS DESIGN Eh I USE EXISTING 1,000 GALLON SEPTIC TANK
- 500 j
Permit valid for REPAIR OF SEPTIC Sk',1FNl
ONLY, due to state and Local septic val,.,,,,es,
of
anyrdfuture Health
uldit"n
tns/renovationa��,, , is i t""nst for
swage facilities ,Pit/or structures/d%s, (t ',;;.
yarwouth Health Dui-
APPP4,01'i I
�Z� 2o2L
Na Date
CHAMBERS E�T�C EXISTING UNDERGROUND UTILITIES
GARAGE\ j W W . EXISTING WATER LINE
MAP 89 ���� \<` / I PROPOSED / INSTALL 2 - 500 GAL. CHAMBERS w/AGGREGATE DEC 0 9 ZOi�
�'�-' , DISTRIBUTION BOX 34x3' / \\ i TEST PIT LOCATION
006' j - HC -1 ` SIDEWALL CAPACITY
HEALTH DE^ T.
LOT 83 �
3) 71P (LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0.74 GPD/S.F.) GAUDAY -' EXISTING 1,000 GALLON SEPTIC TANK
PROPOSED (25.01+12.83')(2) (21) ( 0.74 GPD/ S.F.) =112.0 GAUDAY
Benchmark 2 - _� - 3�`/ / INSPECTION PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE
Lower Cnr. StepBOTTOM CAPACITY
gq .: PORT
HC -2
Elev. = 35.47 ����� (2) 34x9'
20 TP1 d
Approx. MSL ¢ M (LENGTH x WIDTH) (0.74 GPD/S.F.) = GAUDAY
10" i 33x5 PROPOSED DISTRIBUTION BOX
i , \\ (25.0'x 12.83') (0.74 GPD/S.F.)' = 237.4 GAUDAY
PROPOSED 500 GALLON LEACHING CHAMBER
STUMP0 14"
22" \
N i 4 -z TOTALS:
00
...:. Y
z REV. DATE TOTAL NUMBER OF CHAMBERS 2 j
B APP'D. DESCRIPTION
'U TOTAL LEACHING AREA 472.2 SQ.FT.
< SHRUBJ TOTAL LEACHING CAPACITY 349.4 GAL./DAY PROPOSED SEPTIC SYSTEM UPGRADE
\ OF
PREPARED FOR:
7\ ,. MORSGs
y�T
o I\ JOHN L. a CAPEWIDE ENTERPRISES
�h0 QL CHURCHILL JR. it;
N0.48066 c
`� i o °� o �� LOCATED AT
a y \ 16„
'". Q o.. STUMP 10" ° g L 1 AVERY LANE
Ag
NOTES: Benchmark 1 �- °� 34x1' GAs GP l SOUTH YARMOUTH, MA 02664
Top CBDH < GAS
�_ GAS 35 I
1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF Elev. = 35.00' �. w m N83,26'0() „E AS GAS / ` I SCALE: ' 1 INCH = 10 FT. DATE: DECEMBER 3, 2019
EACH SEPTIC SYSTEM COMPONENT. Approx. MSL 63.98, GAS GAs G
2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE L
GAS OF 0 5 10 20 40 FEET
�.
PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT .\' x 4 ' GAS JOHN L ���, PREPARED BY:
DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF CB/DH ELEC. -�''INC.
HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. 0 HA ,DHOLE
RESERVED FOR BOARD OF HEALTH USE CHURCHILL JR. N JC ENGINEERING, INC
UT Box No: 418072854 CRANBERRY HIGHWAY
3.) ENTIRE PROPERTY IS LOCATED WITHIN A DEP APPROVED ZONE II. Y STREET ct EAST WAREHAM, MA 02538
D ONLY ASA COURTESY - BARN" P NATE �YOUT)
4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDE O
FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS SITE.
� T (40� VVI�E 50$.273.0377
IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL S I 1 PLAN
Drawn By: ATB Designed By: ATB Checked By: MCP JOB No. 4929
NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT. I SCALE: 1" = 10'
w.