Loading...
HomeMy WebLinkAboutBld-20-002553 , ONE & TWO FAMILY ONLY- BUILDING PERMIT Town of Yarmouth Building Department 1146 Route 28, South Yarmouth,MA 02664-4492 508-398-2231 ext. 1261 Fax 508-398-0836 fi.�'' Massachusetts State Building Code,780 CMR � ' Building Permit Application To Construct, Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: LLo- All oZgScs___3Date ed: FlEcrivED Building Official(Print Name) $ OCT 2 SECTION 1:SITE INFORMATION. 1.1 Property Address: 1.2 Assessors Map&Parcel u-?� I N G DEPARTMENT 13 MacKenzie Road South Yarmouth 25 — 1.1 a Is this an accepted street?yes no Map Number Parcel Number - 1.3 Zoning Information: 1.4 Property Dimensions: C it-41 1010 .2 acres 0 1 el (eZ Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,154) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private CI _ Outside Flood Zone? Municipal 0 On site disposal system CICheck if XesO SECTION 2: PROPERTY Q IV`NERSWP' 2.1 Owner'of Record: Jorge Colina Name(Print) City,State,ZIP 13 MacKenzie Road South Yarmouth 508-398-6583 gcolina©comcast.net No.and Street Telephone Email Address SECTION_ t,DZS4IPTIOS OF PROPOSED WORK ;(check' that apply) New Construction❑ Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition ❑ Accessory Bldg.0 Number of Units Other 0 Specify: Brief Description of Proposed Worltz: flush mounted on rear of building 518kW :SECTION 4:.ESUMATED: O STRU TIt COSTS Item Estimated Costs: : oftrelBI se Onif ' (Labor and Materials) ,' 1.Building $ 17,094 ^1. Building PermitFee:S► r Indicate how fee is determined: 2.Electrical $ _13 Standard CityfF'oV n . Olio h 0 Dotal Project Costs(Item 6)x multiplier—x 3.Plumbing $ 2 Other.Fees: $ 4.Mechanical (HVAC) $ List ' 5.Mechanical (Fire Suppression) $ Total All Fees:$ Check N0. Check=Attiouilit: Amount: 6.Total Project Cost: $ 17,094 El Paid in Hill 0 Outstanding Bila4ce Dde; SECTIONS:.CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 088921 9/18/21 Neal Holmgren License Number Expiration Date Name of CSL Holder 75 Spring Hill Road List CSL Type(see below) U No.and Street Type Description East Sandwich MA 02537 U Unrestricted(Buildings up to 35,000 cu.ft.) R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry, RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 508 744 6284 info@solarrising.net I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(SIC) 175578 5/28/20 Solar Rising LLC/Neal Holmgren HIC Company Name or HIC Registrant Name HIC Registration Number Expiration Date 759 Falmouth Road Unit 8 info@solarrising.net No.and Street Email address Mashpee MA 02649 508 744 6284 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit Signed Affidavit Attached? Yes No 0 • . SECTION 7a OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR.APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize to act on my behalf;in all matters relative to work authorized by this building permit application. see attached consent form Print Owner's Name(Electronic Signature) Date • SECTION 7b:OWNER1 OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. /tAte2.1YV64 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will trot have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/ocaInformation on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.fl.) . Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" C ' TOWN OF YARMOUTH •r O BUILDINGDEPARTMENT , 1146 Route 28,South Yarmouth,MA 02664 60' 508-398-2231 ext. 1261 Fax 508-398-0836 BUILDING DEPARTMENT DEMOLITION DEBRIS DISPOSAL AFFIDAVIT Pursuant to M.G.L. Chapter 40, Section 54 and 780 CMR, Chapter 1, Section 111.5, I hereby certify that the debris resulting from the proposed work/demolition to be conducted at 13 MacKenzie Road Work Address Is to be disposed of at the following location: bamstable transfer station Said disposal site shall be a licensed solid waste facility as defined by M.G.L. Chapter 111, Section 150A. Altai/404144.4.- Signature of Application Date Permit No. C6904/12/112.042Weaa /A ,t. Office of Consumer Affairs and Business Regulation One Ashburton Place - Suite 1301 Boston, Massachusetts 02108 Home Improvement Contractor Registration Type: Supplement Card SOLAR RISING LLC Registration: 17557E 759 FALMOUTH RD 8 Expiration: 05/27/2020 MASHPEE,MA 02649 Update Address and Return Card. SCA t e9 20M-05/17 —1I4"*(7n,mar,u,ra//A nfr irenlerrAi/JP//J Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE:Supplement Card before the expiration date. If found return to: Registration Expiration Office of Consumer Affairs and Business Regulation 175578 05/27/2020 One Ashburton Place-Suite 1301 SOLAR RISING LLC Boston,MA 02108 Altai 4.44e NEAL HOLMGREN 710 L 759 FALMOUTH RD 8 Ci MASHPEE,MA 02649 Undersecretary Not valid without signature L. Commonwealth of Massachusetts 9/- Division of Professional Licensure Board of Building Regulations and Standards Const,iwi t Attipprvisor CS-088921 ? Tres:09/18/202 t ii S y NEAL F HOL `t 'f ' l c r 76 SPRING HAL 1 EAST SAttDWI' !�. f,, .1 r)/Sti•i:1L1� Commissioner The Commonwealth of Massachusetts = � 1 Department of Industrial Accidents = ml=h 1 Congress Street Suite 100 :_ -�yv Boston, MA 02114-2017 ,r www mas&'gov/d a Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY, Applicant Information Please Print Legibly Name(Business/Organization/Individual): Solar Rising LLC Address: 759 Falmouth Rd Ste 8 City/State/Zip: Mashpee MA 02649 Phone#: 508-744-6284 Are you au employer?Check the appropriate box: Type of project(required): 1.®I am a employer with 2 employees(ftill and/or part-time).' 7. ❑New construction 20 I am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling any capacity [No workers'comp.insurance required.] 3.0 1 am a homeowner doing all work myself.[No workers'comp,insurance required.]' 9. ❑Demolition 4.0I am a homeowner and will be hiring contractors to conduct all work on my property. I will 10 Building addition ensure that all contractors either have workers'compensation insurance or are sole 11,[]Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. (3. Roof repairs These sub-contractors have employees and have workers'comp.insurance.t ❑ p 6,❑We are a corporation and its officers have exercised their right of exemption per MGL c. 14.®Other Solar 152,*1(4),and we have no employees.[No workers'comp insurance required] *Any applicant that checks box 01 must also fill out the section below showing their workers'compensation policy information. Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees, If the sub-contractors have employees,they must provide their workers'comp policy number. I am an employer that is providing workers'compensation Insurance for my employees. Below is the policy and job site Information. Insurance Company Name: Travelers Indemnity Company Policy#or Self-ins. Lic.#: 6HUB-53677050-18 Expiration Date: 11-02-2019 Job Site Address: City/State/Zip: Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature: 1',��r anti Date: 1110-2016 Phone#: 508-744-6284 Official use only. Do not write in this area,to be completed by city or town officiaL City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4, Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person! Phan•!!• ACORO� DATE(MMIDDWYYY) CO CERTIFICATE OF LIABILITY INSURANCE 11/05/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the polloy(Ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER wig: John Lynch IV PAUL PETERS AGENCY INC 44Extp (508)477-0021 Pkg „ ,No,; L ADDRESS: laY epa u IpetersagenCy.Co m 680 FALMOUTH RD INSURER(S)AFFORDING COVERAGE NAICs MASHPEE MA 02649 INSURER A: TRAVELERS INDEMNITY CO OF AMERICA 25666 INSURED INSURER S: SOLAR RISING LLC INSURERC: INSURER D: 759 FALMOUTH RD UNIT 8 INSURER E__ MASHPEE MA 02649 INSURERF; COVERAGES CERTIFICATE NUMBER: 333912 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL/HE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES,UMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPE OF INSURANCE Ube W Ve POLICY NUMBER itag YY1 AA 1 UMITS COMMERCIAL GENERAL UASIUTY EACH OCCURRENCE S CLAIMS MADE OCCUR PBEMISES(Ea ccurrenca) S MED EXP(Any one person) S N/A PERSONAL&ADV INJURY S GEN'L AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE S POLICY pRp Pol r JECT ( ,y LOC PRODUCTS•COMP/OP AGO S 11 OTHER, I : AUTOMOe1LELUIMLITY COMBINED SINGLE LIMIT S i Agl eecMen0 ~I BODILY INJURY(Per person) S ANY AUTO _ AALL OOSWNED SCYT1 LED N/A BODILY INJURY(Per accident) S NON-OWNED PROPERTY DAMAGE HIRED AUTOS I --- AUTOS (Forinsisilnt).. S UMBRELLA UM IOCCUR EACH OCCURRENCE S EXCESS LAB F I,ClAIMS•MADEI N/A AGGREGATE S DED I RETENTIONS WORKERS COMPENSATION I x PER OTH• AND EMPLOYERS'LIABILITY Y/NANYPROPRIET ?STATUTE ER A OFFIC EMSOEREXCLUDED?ECUTIVE WA WA WA 6HUB5B67705018 11/02/2018 11/02/2019 E®L.EACH ACCIDENT S 1,000,000 !(Mandatory In NH) E.L.DISEASE-EA EMPLOYEE S 1,000,000 +If yes,describe under DESCRIPTION OF OPERATIONS below i E.L.DISEASE•POLICY LIMIT (S 1,000,000 N/A ! I I I DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Workers'Compensation benefits will be paid to Massachusetts employees only.Pursuant to Endorsement WC 20 03 06 B,no authorization Is given to pay claims for benefits to employees in states other than Massachusetts If the insured hires,or has hired those employees outside of Massachusetts. This certificate of insurance shows the policy in force on the date that this certificate was Issued(unless the expiration date on the above policy precedes the Issue date of this certificate of Insurance). The status of this coverage can be monitored daily by accessing the Proof of Coverage-Coverage Verification Search tool at www.mase.govilwd/workers-compensationiinvestigations/. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Solar Rising LLC ACCORDANCE WITH THE POLICY PROVISIONS. 759 Falmouth Rd Unit 8 AUTHORIZED REPRESENTATIVE Mashpee MA 02849 ....� Daniel M.Cro4v by,CPCU,Vice President—Residual Market—WCRIBMA ®1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD �'r1 SOLARII OP ID:JL '4 L CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) o3/1a/aola THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CCAOINTACT Paul Peters Insurance Agency PHONE -Fq)( 880 Falmouth Rd. 0 610; _ {A/c,No): Mashpee,MA 02849• nss: John J.Lynch,IV INSURERS)AFFORDING COVERAGE NAIC S INSURER A:PILGRIM INSURANCE CO INSURED Solar Rising LLC INSURER a:Western World 759 Falmouth Rd Unit 8 INSURER C:Lloyds of London Mashpee,MA 02649 INSURER 0: INSURER I: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LY1! TYPE 0/INSURANCE A,(yiR SWIM IAND POLICY NUMIER HAM/OPOL�DIIYYYYI (MPM POLICY UNITS GENERAL LIAaIUTY EACH OCCURRENCE $ 1,000,000 B X COMMERCIAL GENERAL LIABILITY PREMISESPEM Ma occurrence)c $ 100,000 CLAIMS-MADE X OCCUR MED EXP(My one person) $ 5,000 X ISO From CG0001 NPP8479454 03/09/2019 03/09/2020 PERSONAL&ADV INJURY $ 1,000,000 X Contractual Llab GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS••COMP/OP AGO $ 2,000,000 POLICY n gla n LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accllint) $ 1,000,000 A _ ANY AUTO PGC00001018498 10/30/2018 10/30/2019 BODILY INJURY(Per person) $ X AUTOWNED X AUTOSULED BODILY INJURY(Per accident) $ X HIRED AUTOS X NON-OWNED PROPERTY DAMAGE $ AUTOS (PER ACCIDENTL $ UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS UAB CLAIMS•MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION WC STATU- OTH• AND EMPLOYERS'UASIUTY YIN TORY LIMITS ER ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICERIMEMBER EXCLUDED? N I A E.L.EACH ACCIDENT $ (Mandatory In NH) — E.L.DISEASE-EA EMPLOYEE $ K yes describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE•POLICY LIMIT $ C Inland XSZ121439 11/08/2018 11/08/2019 50,000 Marine DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 101,Additional Remarks Schedule,It more space Is required) CERTIFICATE HOLDER CANCELLATION NEWT003 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE City of Newton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 1000 Commonwealth Ave ACCORDANCE WITH THE POLICY PROVISIONS. Newton,MA 02459 .9*AUTHORIZED REPRESENTATIVE A John J.Lynch,IV / e' i 01988.2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD Tom Petersen Architects • Planners Construction Official October 8,2019 Building Department for project at: 13 MacKenzie Road South Yarmouth,MA 02664 Re: Solar Panel Installation Colina Residence 13 MacKenzie Road South Yarmouth, MA 02664 Dear Sirs, I've reviewed the proposed solar panel installation at this location to evaluate the existing roof structure and the connection of the panels to the roof. Criteria: Applicable codes: MA State Building Code—780 CMR,9th Edition (2015 International Residential Code with MA Amendments) 2015 Wood Frame Construction Manual Design roof load: 30 psf live load, 10 psf dead load,40 psf total load Design wind load: 140 mph,35 psf; Exposure Category 'B' My findings are as follows. I. The new solar panels will imply an additional dead load of 3 psf. The existing roof structure (2x6 roof rafters @ 16"o.c.,with 2x8 ridge, span=+/- 10'-6")is sufficient to bear this additional load. 2. The solar panels are attached to the roof with the SolarMount-1 rack system by UNIRAC. The rack system,roof connections and connection spacing are rated for 140 mph. This project requires the larger Solar Mount 1-2.5 beam(2.5"high)and spacing of flange foot connection to roof at 48"o.c.maximum. Flange footing connections to the rail are nit required to be staggered. The flange foot connections to the roof are 5/16"diameter x 4" long lag bolts. I therefore certify that this installation complies with the applicable codes and design loads mentioned above and is acceptable for approval. Please let me know if you have any questions on this information. Thanks! Sin ly yours, 49. DP Root 0. S 1 No.31821 $ NOWELL, Tom Petersen �o NJ• �ro 64' Cc: Neal Holmgren,Solar Rising LLC '44/OF 014, 6 6 t^ 6 Country Lane•Howell,New Jersey 07731 *Telephone 732-730-1763,Fax 732-730-1783 Credal Re.2 •} Zx6 it O ��I °A ManlierIlya!Railcars[Sea.Lead) • . na.re..Ciusliq • O H No.31621 z in *masa rs _ _ • HOWELL, m Wet service condm.ns. p N , Jas Re it E:rwkr ExposurelnCiild lumber" • ylylo' ...a Sam Lead tam 2'i %♦'a cakda.ila+i..ar$.ri ontal Spay I fm to Sear Optima Calculator for riooe Isms 6 Rafters UNITS Of USE I sap I —RESTART I ,,,,,,,,,,,,,, ,,,;,,..;,: Span ra;CuiatOr'Or Wood O App Store ,.;oroasis anIFtdiO Raftteters available 2x 10 $par OaKU'ato,!?. 1400d - -- ,,t, ,j, Joists and Rafters also available for the Android OS The Maximum Horizontal Span is 11 ft. 11 in. with a minimum bearing length of 0.5 in. required at each end of the member. . 26 111. p.w , , .rm.Fn __--.i Ganda_ err __ rim '2e6 atcddua of E"taauc:n E 1400000 pa Bvgiain ivvutb:t 1_Wi3d pu 8eassl Srreattb T p �....r pm _. Sb.a Saengtln T,.' l5S35 en - Solar Rising LLC Project: George Colina Solar Rising Building Permit Plans Solar 508-744-6284 759 13 MacKenzieRoad Revision: 10/09/19 / , 4 i Falmouth Rd Unit 8 Scale: None Mashpee, Ma 02649 SouthYarmouth MA 02664 1 Drawn By: Neal Hoimgren .. Grid Tied Photovoltaic System DC Rating 5.18kW George Colina 13 MacKenzieRoad SouthYarmouth, MA 02664 • Site Details: All Work To be in Compliance with: Solar Rising shall install a 5.18 kW grid-tied 2014 National Electrical Code (NEC) Photovoltaic system comprised of(14) LG 370 Modules with 2009 International Residentail Code (IRC) (14) Enphase Energy IQ7+ Micro-Inverters. The Modules will 2009 International Building Code (IBC) be flush mounted to the Asphalt roof. 2012 International Fire Code (IFC) MA 780 CMR 8th Edition ASCE/ANSI 7-05 Minimum Design Loads for Buildings and other Structures. Equipment Specifications: Modules: (14) LG Solar 370 Inverters: (14) Enphase Energy IQ7+ Racking: Unirac Solar Mount Attachments: EcoFasten Flashing with 4" Stainless • Steel Lag Bolts f' Roof Specifications: Roof Structure Asphalt 2X6 Rafters 16" 0/C et Pitch: 10° Azimuth: 270° Site Specifications: Occupancy: II Design Wind Speed: 110 MPH Mean Roof Height: 22ft Ground Snow Load: 30 PSF I Solar Rising LLC Project: George Colina Solar Rising Building Permit Plans Solar)5087446284 759 13 MacKenzieRoad Revision: 10/09/16 Falmouth Rd Unit 8 Scale: None e7Mash pee, Ma 02649 SouthYarmouth, MA 02664 P Drawn By: Neal Holmgren 4 m . jz t •Quantity of attachments = 28@ 48" O.C. 'Maximum UniRac Rail span = 48"O.C. •Maximum Allowable Cantilever = 16" 'Racking and Attachment: UniRac Solar Mount with •lag screw, Hex Head, 18-8 SS 5/16" x 4" Length •Array Installed According to the UniRac Solar Mount Code-Compliant Installation Manual. Solar Rising LLC • Solar Rising Building Permit Plan Solar508-744-6284 75g Project: George Colina Revision: 10/09/19 Falmouth Rd Unit 8 13 MacKenzieRoad Scale: None 9 Mashpee, Ma 02649 SouthYarmouth, MA 02664 Drawn By: Neal Holmgren 5paeir taruorfimo-flr ! ; 11 ' Sire 2x6 Grade No.2 !im►or T . Raftsra isnoN Load} ♦! 2x6 Manias Limit 1/190 _ Spadaq(l) 16 Wet service conditions? liateri.r Exposure--NO incised lumber? No .- Snow Load(pot) 0 2 Dead Load(psf)i 10 Calculate Naxiawur Horizontal Span I Go to Span Options Calculator for Wood Joists a Rafters I LOUTS OF USE I HELP I RESTART I ,,,,t,... ,-,, -,..... Span Calculator alculator for Wood © App Store fj°sfs arheaiPhaRateftesavailabl e 2X 1 O Span Calculator for Wood l ,,, I. . . .Joists and Rafters also available for the Android OS. The Maximum Horizontal Span is: 11 ft. 11 in. With a minimum bearing length of 0.5 in. required at each end of the member. 26, may.- --_____1Ottil* rr fi"'de ----______ ___. ,No.s - — Siaa _�—- ------2io6 B itdr S iF (E)__ soi.�i J Jo1eoaoi _ �sd+TpoiL Strasitk(F,p) 5 psi Slum Sl Strength(Fr1 55.25 psi Solar Rising LLC Project: George Colina Solar Rising Building Permit Plans Solar 1508-744-6284 759 13 MacKenzieRoad Revision: 10/09/19 f Falmouth Rd Unit 8 Scale: None Mashpee, Ma 02649 SouthYarmouth, MA 02664 Drawn By: Neal Holmgren ., GreenFazten"GF 1-Product Guide Cut Sheets.GF14 tt . ii ..77..--z. - ME °1' , * r A I RA it A t j j r SECTION A-A '''- On Or, r Itg.' 'I,.r an4S99999 Ewaml lMlet of RenewableE t .s-.i SalA9m'hnl eE .,. v S+PWK a�9Y P mp,tlglYCNd916nsd 10/19/11 ll Solar Modules to be flush mounted to existing roof structure and set above shingles 4" Solar Rising LLC Project: George Colina Solar Rising Building Permit Plans Solar 508-744-6284 759 13 MacKenzieRoad—ft ::: °' isi : 10/09/19 Falmouth Rd Unit 8 le: None '` ' 1 1-79 Mashpee, Ma 02649 SouthYarmouth, MA 02664 Drawn By: Neal Holmgren . v #a 4 a !I.! ! ! t i !il 1 3 H. ! ! ! s ! A ! 02° I i EIII 1 g , i' a l /ii 1 jiff iiiill = 1 till ! lit] 111 I /Ili 1 III ! ".IJ Ill!'" ir " * t ilitt! liti ire I J., giiii . 1 is Ej ill P Fat, :is 11 . . . . . . . . I ; ill . . . . . . . . . . h k f ul'la V, j spxga:"� � > o 1g "'� ' ' .4 ; III li ai: I _ 4...„.•- 11- ' ,,„ li o x 1c { I N 'Li ' I I 11, ! ! ! ..-1N P1♦) i �� � T1i i 111I 1111111 l ! ill l l i l ]M l l I 1 � �eEla fit i�ra° N 111 II 1 iii ' i xialii, rot III itiii i ii 'till i 111 I ! $I I ii i 1 11 i t i a • . . . �. 111 ill _ r' II ! 1 ii ' , li 1 i , 1 zAr 1 i { i i i 1I31 i 1 o 1t o zi I; . .f!Jill!! I 0 vl 'u Z- :_iliiin_1 . I is Ii ir i r o ist %% % % % El F. :- la 1 ____ 7.-09 1 r! H-1 4„ , , , , f 1 2ii I f N;,: bbb1111I r o Fo: "4 1 j a; j M! V 1 il i if ti I . Iii I ill I 'ill 1 ill 11 Mill ' !ii .:Iiiiiii hill/0 1% 111 11 p di 11/11111illill I ;l,!JI : c• ,1 _.III JJ4!tr' 41 ; . . . . fig - 1 " -4 ;. ):. A. li li i - 1 Vi ,- , I 5 1 `; 3 E il 0 1 - , 1 I 0 not SEeet Enphase Microinverters Revlon:AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7 Micro"" and Enphase IQ 7+ Micron" IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. i M eroi nverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ Battery",and the Enphase Enlighten' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) I� Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules =mom& • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready 141 I F • Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) (1111) *The IQ 7+Micro is required to support 72-cell modules. sare�' To learn more about Enphase offerings,visit enphase.com E N P HAS E: Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module lsc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L•L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port Ill ill AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6% 97.6% 97.5% 97.3% -___ CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: -PV2 to MC4:order ECA-S20-S22 -PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https•//enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com v EN P H AS E. 2018 Enphase Energy All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 018-11-19 I...G NoN(,„R ,, ...... . , _�:„ ,. , ,. . ir;4 . ,. ,. ,r 60 LG370Q1 C-V5 I LG365Q1 C-VS 370W 1365W /-- —__� LG NeON®R is powerful solar module that provides world-class performance. / _ - --�-�._._ A new cell structure that eliminates electrodes on the front maximizes the / ,. - ' utilization of light and enhances reliability. ` - _ ' _ LG NeON®R is a result of LG's efforts to increase customer's values beyond _ ' efficiency.LG NeON°R features enhanced durability,performance under real -world conditions,an enhanced warranty and aesthetic design suitable for . roofs. APPROVED MI:OCT °= w 1111 c ® us CE c-,..' T . Feature Aesthetic Roof Extended Product Warranty 4 25 miJ LG NeON°R has been designed with LG has extended the product warranty of the aesthetics in mind:the lack of any electrodes LG NeON°R to 25 years which is top level of on the front creates an improved,modern the industry. aesthetic. Enhanced Performance Warranty Aok More generation per square meter LG NeON°R has an enhanced performance liar The LG NeON°R has been designed to •warranty. After 25 years,LG NeON®R is significantly enhance its output,making it guaranteed to perform at minimum 90.8%of efficient even in limited space. initial performance. - - - _ - - - - LG370Q1 C-V5 I LG365Q1C-V5 General Data Electrical Properties(STC*) Cell Properties(Material/Type) Monocrystalline/N-type Model LG370Q1C-V5 LG36501C-VS Cell Maker LG Maximum Power(Pmax) [W] 370 365 Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) [V] 37.0 36.7 Module Dimensions(L x W x H) 1,700mm x 1,016mm x 40mm MPP Current(impp)- ,(A) 10.01 9.95 ---- Weight 17.5 kg Open Circuit Voltage(Voc.'t5%) [V] --- 42.8 _ 42.8 - - Giass(Thickness/Material) 2.8mm/Tempered Glass with AR Coating Short Circuit Current(1st,*5%) [A] 10.82 10.80 Badcsheet(Color) White Module Efficiency [%J 21.4 21.1 Frame(Material) Anodized Aluminium Power Tolerance [%] 0-+3 Junction Box(Protection Degree) IP68 with 3 Bypass Diodes •STC(Standard Test Condition).Irradiance 1000 W/m,Cell Temperature 25°C,AM 1.5, CaWCs(Lergth) 1,00Cmmx 2EA Measure Tolerance t3% Connectnr(Type/Maker) MC4/MC Operating Conditions Operating Temperature (°C] -40-+90 Certifications and Warranty Maximum System Voltage [v] 1,000 IEC 61215-1/-1-1/2201 6,IEC 61730-1/2.2016 Maximum Series Fuse Rating [A] --_ 20 ISO 9001 ISO ISO S0001 - UL 1703 Mechanical Test Load(Front) [Pa/psf] 5,400/113 Certifications - -.--- Mechanical Test load(Rear) [Pa/psf]. 4,000/83.5 . 14001, OHSAS 18001 •Test Load=Design x Safety Factor(1.5) Salt Mist Corrosion Test IEC 61701:2012 Severity 6 Ammonia Corrosion Test IEC 62716:2013 Packaging Configuration Module Fire Performance Type 1 __r --__- Number of Modules Per Pallet (EA] 25 Fat Rating Class C(UL 790) Number of Modules Per 40ft HQ Container [EA] 650 Product Warranty 25 Years ---_-- __.- -. PackagirgBoxDimerrsimrs(LxwxH): . [mm] 1,750x1,120x1,221 WarrantyOutput Warranty' Packaging Box Gross Weight [kg] 473 of PmIDr Linear •t)F,rst year 98%,2)After 1st year:G.3%arr•uai degradanor•3)9G.8'%for 25years --- Temperature Characteristics NMOr [ •C] j 44±3 Dimensions(mm/inch) Pmax [%rC] -0.30 Vocr, [%!°CJ j 0.24 mssls.o 40 alert 161 1sc'c' [%/°C] I 0.037 976.0/38.4 *NMOT(Nominal Module Operating Temperature).Irradiance 800 Wfm',Ambient temperature 20°C, Dra i n•Ho i es Wind speed 1 m/s,Spectrum AM 1.5 e- t` �' 40.0/1.57 Grounding Holes Electrical Properties(NMOT) ,-. • , , I Mounting Holes•• t' � Model I LG370Q1C-V5 LG365Q1C-V5 I Maximum Power(Pmax): [W] 279 275 MPPVokage(Vmpp) i [V] 36.9 36.6 MPP Current(Trapp) I [A] 7.55 7.51 _ Open Circuit Voltage(Voc) [V] 40.3 40.2 p u° Short Circuit Current(1st) 1 [A] 8.71 t_ 8.70 �U '9 I-V Curves "f 8g • 12 ' 10o0W g 11I 8o0W i I 600W m ii:L. v 4 400W 5 u i 200W 2 1 1.1 11.1 2l1 301 411 Voltage(V) ® LG LG Electronics Inc. Product 0-C-G-F-Ens are subject to change without notice. ❑r[] Solar Business Division DS-VS-60-C-G-F-EN-9C314 LG Twin Towers,128 Yeoui-daero,Yeongdeungpo-gu,Seoul 9 • r' 07336,Korea ©2019 LG Electronics.All rights reserved. 'tiro V Life's Good 0ea www.lg-solarcom 4 ° y