Loading...
HomeMy WebLinkAboutReview Checklists, TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 3 8 Lot Zone of Contribution: In Out " Acreage Commercial: Residential: ir Street: 9 cairce, Raz{. Village: L,/l sf- fetr a Floor Plan: V #Bedrooms: 3 Owner: Ma r/ &-,0 sfr Installer R--v6LElr (�. 5 Co . Address: Phone: Cis-be) 'i o53c6 Phone: �S 49-79'/7 Builder Engineer: Dowel ['4 Address: Phone: (5'08 .4,a- / • Phone: /// N/A YES, NO 1.Required#of copies receivedI/ 2.Date of soils exam and percolation test not older than 2 years /I 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road . H.P.: Fnd: Var.: l0 5.Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands L ,tip f✓ 7. Septic tank minimum 10 ft from foundation, deck Var.: / 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: V 9.Leaching minimum 100 ft from wetlands Var.: V 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: / 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: I 13.Uses adjustment for maximum high groundwater Var.: VV 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: _ 1 `, ' 15.System not in top or subsoil(A,B horizons)or 5'removal Z (?,. 16.Proposed contours are suitable _ 17. System meets slope requirements-min. 1/8", 'A"preferred V 18. System meets brgdkout requirements , PVC liner: Wall: 19.Specified tee sizes are proper, gas ble on outlet tee 20. Sewage is under 10,000 gpd for parcel .1,, 21.No garbage disposal t� 22. System adequately sized for its intended use V 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambersach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28.Septic tank/pump chamber to be factory waterproofed t/, 29.Vent provided if leaching below 3 feet,under driveway/parking 1/ 30.Buoyancy calculations for tank/pump chamber 1(/ 31.Engineer to inspect and certify soils: wall: commercial: V 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 1/7 36.Deed Restriction required max. #bedrooms: max. flow: gpd _ 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: i -5 e›epl"ll 9. 6/03/03 ' Ic3OOt (Q- . °4Y.