HomeMy WebLinkAboutBldsm-20-000975 (2) Page 2 Townsend Wells 8/12/2019 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) -Single pane; Wood frame; Clear glass - No inside shading; Coating: None (clear glass); No outside shading. Window(3) 31.5 sq.ft. 2,678 0 2,678 2,245 -Single pane; Wood frame; Clear glass - No inside shading; Coating: None(clear glass); No outside shading. Door 21 sq.ft. 157 0 157 832 -Wood; Hollow; No storm S Wall 298 sq.ft. 365 0 365 1,931 -Wood frame, with sheathing, siding or brick; R-11 3 1/2 in.; none Glassdoor 42 sq.ft. 1,848 0 1,848 2,994 -Sliding glass door; Single pane; Wood or vinyl frame; Clear glass - No inside shading; Coating: None (clear glass); No outside shading. W Wall 285 sq.ft. 349 0 349 1,847 -Wood frame, with sheathing, siding or brick; R-11 3 1/2 in.; none Window 27 sq.ft. 2,295 0 2,295 1,925 -Single pane; Wood frame; Clear glass - No inside shading; Coating: None (clear glass); No outside shading. Window(2) 28 sq.ft. 2,380 0 2,380 1,996 -Single pane; Wood frame; Clear glass - No inside shading; Coating: None (clear glass); No outside shading. Ceiling 1,806 sq.ft. 2,333 0 2,333 4,941 - Under ventilated attic; R-26 (7.5 inch); Dark Whole House 1,806.3 sq.ft. 22,216 3,049 25,265 73,051 ( 2 tons ) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may vary due to weather and construction differences.