Loading...
HomeMy WebLinkAboutReview Checklist • ' TOWN OF YARMOUTH /e A jS l SEWAGE PLAN REVIEW CHECKLIST Location: ANN MD LOT .. Date of Subdivision Approval Street /1 e L2 _,4 -T G -/t/ ."" Zone of Contribution: In Out Village y/'z t Commercial Residential ) Owner: 7e..S Gaavvred Installer 714i Builder: Engineer -P74, , 3602 ---4S� N/A YES/ NO 1. Required number of copies received. v 2. Date of soils exam and percolation test not older than 2 years. v_..- 3 -/3. 4 Feet of naturally occurring„pervious material, above water table(new construction) 4. Foundation 2 feet above high point of fronting road for new construction. L--- 5. 'Vater availability letter from Water Department for new construction. z_ 6. Benchmark indicated and shown-NGVD if near wetlands. i ./ 7. Building sewer does not exit center of house. 3. 5ertic tan_ a minimum of 10 feet from house and deck. J./ -:. minimum of 20 feet from house and 10 feet from deck. ,/- Leaching a minimum of 100 feet from wetlands. P/6w- /,f(F' 1/ mining a minimum of 150 feet from drinking wells/25 feet from irrigation wells. L/ 12. System meets all other setback requirements. S��/-. 7ext 7;X/i-------- 13. 'L-33. Uses adjustment for maximum high groundwater. -� `:: hR . : =5 feet above adjusted water table or bottom of test pit. L...---- i 5. 15. System not in top or subsoil or 5 foot removal. i/ 16. Proposed contours are suitable. �/' . B=ern Teets slope requirements--min.. "_ 1/4" preferred. 1_,---- 1 9. System meets breakout requirements-peaston elevation-carried out 15 feet minimum. L./ I9. Specified tee sizes are proper. gas baffle on outlet tee. l� 20. Sewage Clow under 10.000 gpd for parcel. L./ 21 . No garbage disposal. C- 22. System adequately sized for its intended use. L--- 23 Minimum 6" stone or ech. 'cal c. , .acted below the i s d d-box. 4. Manhole covers within 6" of grade - septic tank and pump chamber. • 25. Electrical permit for pump chamber. ,.._.---- 26. ✓i26. Pump system - 2" line, weep hole. check valve, sanitary in d-box. alarm on separate circuit. (...---- 27. ----27. Septic tank and pump chamber to be Factory waterproofed.. 7 28. Vent provided if leaching below 3 feet or under driveway or parking, (__----- ' 29. Engineer to inspect and certify : a. clay removal �---- b. wall construction schedule --� c; ommercial system 30. Engineer and Land Surveyor stamp and signature. 31. H2O loading when system subject to vehicular traffic. 32. Title V application and fee signed by a licensed installer, i 33. Foundation footing 2 feet above adiusted water table. .. 34. Lot subdivided prior to July 31_1986 - Nitrate Loading, - 35. Subdivided prior to April 7, 1989 - Phosphorus Zone 300'. t _i P Plan reviewed by: /'