HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH • SEWAGE PLAN REVIEW CHECKLIST - Location: A.M. l Lot 4� Zone of Contribution: In Out CQ Acreage �/ c/1410.4(., Commercial: Residential:Street: 7/ O`Uof zt1 - - / Village: (!PIrc., Floor Plan: #Bedrooms: e%, ffice. -24)50.,f4 Owner: oI Installer: rig-- K------;-''` 6 Address: Phone: Phone: Builder: Engineer: . ��,..v! (A P GGPOO.G: Address: 7 Phone: sof-3& �c-- Phone: t{ it W A'nt / N/ NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years C/ 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,......__--- 5. Water line 10 ft from septic components Var.: t 6.Benchmark indicated and shown-NGVD if near wetlands 7.Septic tank minimum 10 ft from foundation, deck Var.: k.-------- 8. ./8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: -- 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ,-- ,�- 11.Tank/leaching minimum 10 ft from property line Var.: fi \----- 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: /4' tr/c' 5 14.Leaching set 4-5 ft above adj.water or botto ester i1'ar.: ,,x, c- ( '' 15. System not in top or subsoil(A,B horizons) 5'removal ✓� 16.Proposed contours are suitable ,/' 17. System meets slope requirements-min. 1/8", 'A"preferred - 18. System meets breakout requirements PVC liner: Wall: C? 19. Specified tee sizes are proper,gas baffle on outlet tee `./ 20. Sewage is under 10,000 gpd for parcel • 21.No garbage disposal ...__--- 22.System adequately sized for its intended use t_-/ • 23.Minimum 6"stone or compacted below tank and dbox t...------- 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field __--- 26. --'26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size \----- 28. /28.Septic tank/pump chamber to be factory waterproofed \---- 29. --29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature =_� 33. H-20 loading is subject to vehicular traffic,groundwater _.---- 34. 34. Title V Application and permit fee,installer signature C 35.Foundation footing min.2 feet above adjusted ground water for new house . 36.Deed Restriction required max. #bedrooms: max. flow: god c J 37. Check area lots for groundwater/Label groundwater in Assessor's Map c_./ Plan reviewed by: ( 6/03/03