Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2007TOP FNDN. = 21.6' SYSTEMPROFILESCALE) ACCESS COVER TO WITHIN 6" OF FIN. GRADE ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM EL. 19.53' AG�a °+'s� 2" DOUBLE WASHED PEASTONE� RUN PIPE LEVEL EXISTING 1000 0 °� FOR FIRST 2' GALLON SEPTIC±P' QUICK 4 STD INFILTRATORS 18.12 TANK (H- 10 ) GAS TEE a BADDFIF , oo moo 20.83' 00000 , o0 THE INSTALLER SHALL CONFIRM MIN. SEPTIC TANK NEC.) 21 H-20 0 20.82 0 SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR 6" CRUSHED STONE OR MECHANICAL D'BOX RE -USE COMPACTION. (15.221 [21) o�o0 0.67' 4' 000c> DEPTH OF FLOW = TEE SIZES:*THE INSTALLER SHALL VERIFY THE 3/4" TO 1 1/2" DOUBLE WASHED STONE LOCATIONS OF ALL UTILITIES AND ALL INLET DEPTH = 10" BUILDING SEWER OUTLETS AND ELEVATIONS OUTLET DEPTH = 14" PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM FOUNDATION - EXIST SEPTIC TANK EXIST PUMP 91' D' BOX CHAMBER BENCHMARK - TOP OF CONCRETE BOUND \ ELEV. = 20.1' \ CAUTION IN / \ AREA OF GASLINE ALARM ON FLOAT SWITCH SETTINGS: PUMP ON / Off. 2S 00, \ 4' WORKING RANGE LOT 29 2 0 \ PUMP OFF 12939+/- SQ. FT. \ 0.3+/- ACRES ksy/ EXIST. ST AND PC SHELL�\\ TH A \ qp DRIVEWAYS / \�'R0 \ S C/r EXIST. /SEPTIC SYST M TH 2 /(SEE NOTE 10) O T FLAGPO N 0 72S\ 07• 19 18 . 16 / wETcgN� 17 Irk OF f,��s�go w OF M4s�q ARNE yG� ° ARNE c�G� OJA � CIVIL �0 No. 30792 Noo. 6348 �0� QFG1�����<v°F oar S G� FSS\ SURVEY° t _ 7�rZ67 07-162 ARNE H. OJAL , P. E., P.L.S. DATE ra 20 21 3' 3' @ SIDES 2.5' @ ENDS LEACHING FACILITY T .15' 0„ 5" 5' 15.15' (TH 1) 14" 26" v 1000 GAL H-10 S 2" PRESSURE PIPE TO D'BOX perc 800 GAL+ WEEP HOLE SLOPE TO DRAIN BACK TO RESERVE CHECK VALVE PUMP CHAMBER MOTTLING AND GLEYED $' SAND AT 69" ZOELLER 'WASTEMATE' 4- SUBMERSIBLE MODEL M282 1/2 HP PUMP „ 4 SYSTEM (OR EQUAL) 83 EXISTING PUMPCHAMBER MOTTLING 7.5YR 5/8 (NOT TO SCALE) 2.5Y 7/1 CONFIRM PUMP SETTINGS1 PROVIDE APPROX. )6 OF 40 MIL LINER 96" IN AREA SHOWN. TOP AT ELEV. 21.2', BOTTOM AT ELEV. 17.2' wg h - SEPTIC DESIGN: (GARBAGE DISPOSER NOT ALLOWED) RMq/N SEE NOTE 10 DESIGN FLOW: 3 BEDROOMS ( 110 GPD) = 330 GPD USE A3,30 GPD DESIGN -FLOW - - --- - -- \ SEPTIC TANK: 330 GPD ( 2 ) = 660 �i 1 ELEV. wz 20.9' 0" 21.4' A SL 2.5Y 3/2 E LS 10YR 7/1 B LS 2.5Y 6/8 C1 IMS - 2.5Y 7/4 //2 SILT LOAM 5" 14" 18.73' 26' 15.15' 13.98' 77" 108" 12.9' 144" TEST HOLE LOGS SL PROVIDE INSPECTION PORT 2.5Y 3 '2 E WITHIN 3" OF FINAL GRADE ENGINEER: A. OJALA, PE, PLS D. FLA JERTY, RS (TH3) 22.0' WITNESS:BRUCE MURPHY, RS //AMY VON HONE, RS - EXISTING SAS AND IN AREA OF PROPOSED SAS. REPLACE WITH DATE: OCTOBER 11, 2000 JUNE 27, x!007 18.9' < 2 MIN/INCH < 2 MININCH 0.75' MIN PERC. RATE =< SILT LO)\M 2.5Y 6/4 C3 CLASS I SOILS 3' @ SIDES 2.5' @ ENDS LEACHING FACILITY T .15' 0„ 5" 5' 15.15' (TH 1) 14" 26" v 1000 GAL H-10 S 2" PRESSURE PIPE TO D'BOX perc 800 GAL+ WEEP HOLE SLOPE TO DRAIN BACK TO RESERVE CHECK VALVE PUMP CHAMBER MOTTLING AND GLEYED $' SAND AT 69" ZOELLER 'WASTEMATE' 4- SUBMERSIBLE MODEL M282 1/2 HP PUMP „ 4 SYSTEM (OR EQUAL) 83 EXISTING PUMPCHAMBER MOTTLING 7.5YR 5/8 (NOT TO SCALE) 2.5Y 7/1 CONFIRM PUMP SETTINGS1 PROVIDE APPROX. )6 OF 40 MIL LINER 96" IN AREA SHOWN. TOP AT ELEV. 21.2', BOTTOM AT ELEV. 17.2' wg h - SEPTIC DESIGN: (GARBAGE DISPOSER NOT ALLOWED) RMq/N SEE NOTE 10 DESIGN FLOW: 3 BEDROOMS ( 110 GPD) = 330 GPD USE A3,30 GPD DESIGN -FLOW - - --- - -- \ SEPTIC TANK: 330 GPD ( 2 ) = 660 �i 1 ELEV. wz 20.9' 0" 21.4' A SL 2.5Y 3/2 E LS 10YR 7/1 B LS 2.5Y 6/8 C1 IMS - 2.5Y 7/4 //2 SILT LOAM 5" 14" 18.73' 26' 15.15' 13.98' 77" 108" 12.9' 144" 3 Q USED FOR LOT LINE STAKING. SL 22.0' 2.5Y 3 '2 E INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED LS FR )M BOARD OF HEALTH. 10YR 7 /1 B DA LS EXISTING SAS AND IN AREA OF PROPOSED SAS. REPLACE WITH 2.5Y 6 /8 C1 18.9' MS MUI`JICIPAL 2.5Y 7 /4 I SILT LO)\M 2.5Y 6/4 C3 90" FS 4. 2.5Y 6 '3 I 3 Q USED FOR LOT LINE STAKING. 0" 22.0' 18' FILL \ RE -USE A A INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED 19.23' LS FR )M BOARD OF HEALTH. 24" 1OYR 3/3 PUMP CHAMBER B DA LS EXISTING SAS AND IN AREA OF PROPOSED SAS. REPLACE WITH 14.98' 10YR 6/6 CLAN MED. SAND. ENGINEER TO CERTIFY REMOVAL. 37„ 18.9' C1 MUI`JICIPAL 12.4' MFS perc 3. 2.5Y 6/4 MUM PIPE PITCH TO BE 1/8" PER FOOT. 90" 14.5' 96 OBS WATER 14.0 SILT LOAM 120" �5Y 6/1 12.0' H USED FOR LOT LINE STAKING. 8. PIPI - FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. NOTES: \ RE -USE A 1000 GALLON SEPTIC TANK INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED PROVIDE VENT WITH CHARCOAL FILTER FR )M BOARD OF HEALTH. RE -USE PUMP CHAMBER 1. DA JM IS APPROXIMATED FROM QUAD MAP EXISTING SAS AND IN AREA OF PROPOSED SAS. REPLACE WITH 3 PROVIDE NEW H-20 D'BOx OAKS CLAN MED. SAND. ENGINEER TO CERTIFY REMOVAL. LEACHING: 2. MUI`JICIPAL WATER IS EXISTING 2(45 + 8.83) .58 (.74) = 46.2 GPD 3. MIN MUM PIPE PITCH TO BE 1/8" PER FOOT. SIDES: 23 JUL 0 9 2007 4. DEIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 \ BOTTOM: 45 x 8.83 (.74) = 294 GPD 5. PIP = JOINTS TO BE MADE WATERTIGHT.' TOTAL: 459 S.F. 340 GPD 6. CO ISTRUCTION . DETAILS TO BE IN ACCORDANCE WITH MASS. \ USE (10) STANDARD QUICK 4 INFILTRATORS WITH EN\`1RONMENTAL CODE TITLE V. 7 THI(Z PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE 7IQ \ LOT 30 �2S 0> > 13116+/- SQ. FT 0.3+/- ACRES 2.5' STONE AT ENDS, 3' AT SIDES USED FOR LOT LINE STAKING. 8. PIPI - FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COI`11,NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED PROVIDE VENT WITH CHARCOAL FILTER FR )M BOARD OF HEALTH. AND BUGSCREEN (FINAL PLACEMENT WITH Oh HOMEOWNER CONSULTATION) 10. PU AP & REMOVE EXIST. LEACHING FACILITY. REI COVE ALL UNSUITABLE SOIL FOR 5' 'AROUND AND BENEATH EXISTING SAS AND IN AREA OF PROPOSED SAS. REPLACE WITH VARIANCES REQUESTED UNDER TITLE 5 15.405 CLAN MED. SAND. ENGINEER TO CERTIFY REMOVAL. 1a: REQUEST REDUCTION IN SETBACK TO PROPERTY LINE FOR SAS (10' TO 6') "ST-", ", TI TLE 5 SITE PLAN TOWN OF YARMOUTH: Ferrn t va" Id forREPS 111 OF S:'�P' 7C S! 3.4: REQUEST REDUCTION IN SEeTLACK- TO-,cw&TLAND_•-(100 T&�.r93) vzria, -. _�_____ 11 OLD SALT LANE fzGey IL�€s:re ^`i111iC.5/"e°'"� F _�,�1t�r� _?s �, � @ � a d � a a°u 'L w fr':'. . Ing. JUL 0 9 2007 N THE TOWN OF: YARMOUTH(PORT) E -oi l PREPIRED FOR: THOMAS & SUSAN CAREY . off 508-362-4541 LEGEND 20 0 20 40 60 fax 508 362-9880 100.0 PROPOSED SPOT ELEVATION down cape engineering, inc. 100x0 EXISTING SPOT ELEVATION CIVIL ENGINEERS 100 SCALE: 1" = 20' DATE: JUNE 28,, 2007 BOARD OF HEALTH LAND SURVEYORS PROPOSED CONTOUR 100 EXISTING CONTOUR MA 939 main St. yarmouth, ma 02675 REV JULY 2, 2007 (4' TO 5) n�-