HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
4/5 SEWAGE PLAN REVIEW CHECKLIST
Location: AM '33 LOT 73 Date of Subdivision Approval
Street cf:D 7 / # -28 Zone of Contribution: In Out_ ____
Village Si" . G�Aysiv?* Commercial Residential
Owner: Akeirt /P`C Installers
Builder: Engineer A w--4' 7f�/iltiv-:
36 Z - S4
N/A YES NO
1_Required number of copies received. .iv
2. Date of soils exam and percolation test not older than 2 years. r/'
3. 4 feet of naturally occurring peevious material. above water table(new construction) 1.----
4.
4. Foundation 2 feet above high point of fronting road for new construction.
5. Water availability letter from Water Department for new construction
6. Benchmark indicated and shown-NGVD if near wetlands.
7. B ' .in. -w- de - •telt - -r . I. _..
8. Septic tank a minimum of 10 feet from house and deck. ‘1.. ---
9. Leaching a minimum of 20 feet from house and 10 feet from deck. 1/
10. Leaching a minimum of 100 feet from wetlands.
11. Leaching a minimum of 150 feet from drinking wells/25 feet from irrigation wells.
12. System meets all other setback - •uirements. tom'
. a i f. L..U U n t. i L it u idwater
14. Leaching 4 -5 feet above adjusted water table or bottom of test pit
15. System not in top or subsoil or 5 foot removal.
16. Proposed contours are suitable.
17. System meets slope requirements- min. 1/8". 1/4" preferred. 1/-
18.
18. System meets breakout requirements- peastone elevation carried out 15 feet minimum. ../"
19 specified tee sizes are roper gas bale on outlet tee i/
20. Sewage flow under 10.000 gpd for parcel.
21. No garbage disposal.
22 System adequately sized for its intended use:
23. Minimum 6" stone or mechanically compacted below the tank and d-box.
24. Manhole covers within 6" of grade -septic tank and pump chamber. t/-
25.
/25. Electrical permit for pump chamber. •
26. Pump system-2" line. weep hole. check valve. sanitary in d-box. alarm on separate circuit. L./-:,,/
27. Septic tank and pump chamber to be Factory waterproofed. v�
28. Vent provided if leaching below 3 feet or under driveway or parking.
29. Engineer to inspect and certify : a. clay removal
b. wall construction schedule
c. commercial system I .
30. Eng; eer and Land Surveyor stamp and signature. t.
31. H2O loading when system subject to vehicular traffic. c/
32. Title V application and fee signed by a licensed installer.
33. Foundation footing 2 feet above adjusted water table. c_
4. of ubd"vided .nor a Jul 31 9:6 - itr.te L. . .* •
35. Subdivided prior to April 7. 1989 - Phosphorus Zone 300'.
Plan reviewed by: 0