Loading...
HomeMy WebLinkAboutReview Checklist 9/5 ° Za °1-- TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST „---- Location: Location: A.M. & Lot -7:5 Zone of Contribution: In Out Acreage Commercial: Residential. �� Street: . / cY,a/,,k. 6,, ,,,6Q7, Village: hr's/ ��,7� `j - / Floor Plan: ,, #Bedrooms: ,�j Owner: 3-2;4-, , '/D) .7-e) Installer: / -=,.',--/- g. 0 C,-re- 6 - Address: Phone: Phone: -a,'- -3--5f..) Builder: Engineer: •r.. - 4I4 6- .,vim / Address: ' Phone: • _;, 36. 9� Phone: N/A YES NO 1.Required#of copies received ei z. 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 1 j 5.Water line 10 ft from septic components Var.: i// 6.Benchmark indicated and shown-NGVD if near wetlands ✓ 7. Septic tank minimum 10 ft from foundation, deck Var.: -- r S6(-16 V 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: IV 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: 1r 12. System meets all other setback requirements Var.: V' 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: ,/ 15. System not in top or subsoil(A,B horizons)or 5'removal A 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 'A"preferred . V 18. System meets breakout requirements PVC liner: Wall: / 19. Specified tee sizes are proper, gas baffle on outlet tee V 20. Sewage is under 10,000 gpd for parcel t 21.No garbage disposal V 22. System adequately sized for its intended use ,, 23.Minimum 6"stone or compacted below tank and dbox V 24.Manhole covers within 6"of grade,pump chamber cover to grade ,, 25.Inspection port on plastic chambers/leach field i 26.Electrical permit for pump chamber/Separate meter for duplexes / 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size ✓s 28. Septic tank/pump chamber to be factory waterproofed ✓ 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 1//1 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 1 33.H-20 loading is subject to vehicular traffic, groundwater ✓/ 34. Title V Application and permit fee, installer signature j 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37.Check area lots for groundwater/Label groundwater in Assessor's Map V Plan reviewed by: c'hik, ►4t1g 6/03/03