HomeMy WebLinkAboutEngineered Plan - 2018TOP OF FOUNDATION 7 EL= 108.0 4 m 105.00 104.00 0 24" diameter concrete covers raised to within 6" of finish grade (or as noted) EL= l 06.0(mm) / 05.2+ lnspection Port and cap with magnetic marking tape to within 3" of grade EL=/06,7± �' EL=/04.3-/06.5 3 I t 1 105.5_ �- 10.3.5.± � x /03.20 Ioa /0 Til N° " ° - - In N Gas Baffle 102.20 �abel Flter (Town rQegu/anon) -� Longest Run 71-11Af (35) AD5 ARC36f1C LEACH 9' CHAM35R5 IN BED CONFIGURATION D3_0 WITH F1 X1- (5) ROWS OF 5V 5V (7) 1500 GALLON (1-1-20 Rated) CNAMBER5 SEPTIC TANK D -BOX LEACH Ch'AMBfR5 FLOW PROFILE it CONSTRUCTION NOTES J .) ALL wuKr\ SnHLL GVNrUKM 10 THE STATE ENVIRONMENTAL CODE, TITLE 5 (31 O CMR 15,000): AND THE REGULATIONS OF THE LOCAL BOARD OF HEALTH. 2.) ANY SEPTIC SYSTEM COMPONENT INSTALLED IN A LOCATION WHERE THERE IS POTENTIAL FOR VEHICLES OR HEAVY EQUIPMENT TO PA55 OVER IT SHALL BE DESIGNED TO WITHSTAND AN H-20 LOADING. IF UNDER AN IMPERVIOUS SURFACE, 5YS1-EM SHALL BE VENTED TO THE ATMOSPHERE. 3.) TO MINIMIZE UNEVEN SETTLING, SEPTIC TANKS SHALL BE INSTALLED ON A STABLE MECHANICALLY -COMPACTED BASE ON 51X INCHES OF CRUSHED STONE, 4.) COVERS OVER THE INLET AND OUTLET TEES OF THE SEPTIC TANK, THE DISTRIBUTION BOX, AND THE SOIL ABSORPTION SYSTEM SHALL BE RAISED TO WITHIN G" OF FINAL GRADE. LEACHING FIELDS, TRENCHES, AND OTHER SOIL ABSORPTION SYSTEMS WITHOUT ACCE55 MANHOLES SHALL HAVE AT LEAST ONE (1) INSPECTION PORT CONSISTING OF PERFORATED 4" PVC PIPE PLACED VERTICALLY TO THE BOTTOM OF THE SOIL ABSORPTION SYSTEM WITH A CAP, TIED WITH MAGNETIC MARKING TAPE, ACCESSIBLE TO WITHIN 3" OF FINAL GRADE. 5.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LE55 THAN 2% FROM THE BUILDING TO THE SEPTIC TANK, AND NOT LESS THAN I % OTHERWISE. G.) DISTRIBUTION LINES FOR THE SOIL ABSORPTION SYSTEM SHALL BE 4" DIAMETER SCHEDULE 40 PVC (OR EQUIVALENT) LAID AT 0.005 FT/FT. UNLESS OTHERWISE NOTED. LINES SHALL BE CAPPED AT END OR AS NOTED. 7.) LINES FROM THE DISTRIBUTION BOX TO BE LEVEL FOR THE FIRST TWO (2) FEET BEFORE PITCHING TO THE SOIL ABSORPTION SYSTEM. DISTRIBUTION BOX SHALL BE WATER TESTED TO ASSURE EVEN DISTRIBUTION, 8.) GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE STRUCTURES IN ORDER TO PROVIDE A WATERTIGHT SEAL. 9.) HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVER THE LIMITS OF THE SEWAGE DISPOSAL FIELD DURING THE COURSE OF CONSTRUCTION OF THE SYSTEM, 10.) IN ACCORDANCE WITH 3 10 CMR 15.22 1, ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE. 1 1 .) THERE ARE NO OTHER KNOWN WELLS WITHIN 100' OF THE PROPOSED SOIL ABSORPTION SYSTEM, 12.) FROM THE DATE OF THE INSTALLATION OF THE 501L ABSORPTION SYSTEM UNTIL RECEIPT OF THE CERTIFICATE OF COMPLIANCE, THE PERIMETER SHALL BE STAKED AND FLAGGED TO PREVENT USE OF THE AREA THAT MAY CAUSE DAMAGE TO THE SYSTEM. 13.) THE DESIGNER WILL NOT BE RESPONSIBLE POR THE SYSTEM AS DESIGNED UNLESS CONSTRUCTED AS SHOWN ON PLAN. ANY CHANGES SHALL BE APPROVED IN WRITING BY THE DESIGNER. 14.) THE BOARD OF HEALTH REQUIRES INSPECTION OF ALL CONSTRUCTION BY AN AGENT OF THE BOARD OF HEALTH AND THE DESIGNER. THE DESIGNER SHALL CERTIFY IN WRITING THAT THE SEWAGE DISPOSAL SYSTEM WAS INSTALLED IN ACCORDANCE WITH THE TERMS OF THE PERMIT AND THE APPROVED PLANS, 48 HOURS ADVANCE NOTICE IS REQUESTED, 15.) LOCATION OF UTILITIES 15 APPROXIMATE AND CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF ANY WORK. THIS INCLUDES, BUT IS NOT LIMITED TO, REQUESTS TO DIG5AFE, ANY PRIVATE UTILITY COMPANIES, AND THE LOCAL WATER DEPARTMENT. I G.) CONTRACTOR SHALL VERIFY THAT ALL WASTELINE5 ARE CONNECTED BY WATER TESTING WITHIN THE DWELLING PRIOR TO INSTALLATION OF ANY SEPTIC COMPONENTS. 17.) CONTRACTOR SHALL VERIFY EXISTING INVERT ELEVATIONS PRIOR TO INSTALLATION OF ANY SEPTIC SYSTEM COMPONENTS. 18.) INSTRUMENT SURVEY CONDUCTED FOR PROPOSED WORK ONLY. SITE PLAN SHALL NOT BE USED FOR STAKING, OR ANY OTHER PURPOSES. NOR SHALL IT BE USED AS A MORTGAGE PLOT PLAN OR TITLE SURVEY. CONFORMANCE TO LOCAL BYLAWS SHALL BE DETERMINED BY THE OWNER PRIOR TO CONSTRUCTION. 19.) THIS PLAN DOES NOT CERTIFY, GUARANTEE OR WARRANTY COMPLIANCE WITH DEEDED OR ZONING BYLAWS, SPECIFICALLY, BUT NOT LIMITED TO, 51DEUNE SETBACKS AND BUILDING HEIGHT RESTRICTIONS. OWNER IS RESPONSIBLE FOR OBTAINING SUCH A DETERMINATION FROM THE APPROPRIATE AUTHORITY. 20.) TEST HOLES COMPLETED PER STATE ENVIRONMENTAL CODE, TITLE 5. SOILS CAN BE VARIABLE AND TEST HOLE DATA IS NO GUARANTEE OF SOIL CONDITIONS IN OTHER AREAS. IF SOILS DIFFER FROM THOSE SHOWN IN THE SOILS LOGS, DESIGN ENGINEER IS TO INSPECT THE SOILS PRIOR TO PROCEEDING WITH INSTALLATION OF ANY SEPTIC COMPONENTS. 2 1.) SOIL REMOVAL (IF NECESSARY): ALL TOPSOIL ("A" LAYER) AND SUBSOIL ("B" LAYER) SHALL BE REMOVED FOR A DISTANCE OF FIVE (5) FEET LATERALLY FROM THE SOIL ABSORPTION SYSTEM DOWN TO THE CLEAN SAND LAYER (ELEVATION VARIES). AREA TO BE BACKFILLED WITH CLEAN SAND AND COMPACTED TO MINIMIZE SETTLING. 22.) ENGINEER SHALL VERIFY SOILS TO ELEVATION 97.0± PRIOR TO INSTALLATION OF ANY SEPTIC COMPONENTS. 23.) INSTALL A 40 mil HDPE LINER FOR BREAKOUT FROM EL 103.5± TO EL 99.5± A5 SHOWN ON PLAN (SEE PLAN VIEW). NOT TO SCALE 40 m1l. HDPE Liner (5ee Not -,A23) EL=90.3± Bottom of Test Hole 5oi15 to be Verified to EL=97.0± at Time of Installation THIRTY FIVE (35) ADS ARC3GHC LEACH CHAMBERS IN BED CONFIGURATION WITH FIVE Ilk 35' 5' 5' 5' 5' TEST HOLE LOGS 0 -Box 'L-h5pection Ports (See Note #4) PLAN VIEW SCALE: I " = 10'. Test Hole # I (EL= 102 ) Layer Depth Layer 5oi Class Soil Color Comments O"-4" 0 WATER SERVICE LINE I A/E 4"-G" E Loa y Sand I OYR G/ I B G"-47" B Loamy Sand I OYR G/8 C I 47"-72" C I Fin -Medium Sand I OYR GIG Perc @ GO" 72"-85" C2 SdtjLoam 1 OYR 7/2 C3 85"-50' C3 Fin Sand I OYR GIG ® 9G"-125" C4 Silt'Loam 1 OYR G/3 Loamy Sand 125-174" C5 fin San Sand 2.5Y G/4 Loamy Fine Sand �`1t Layer Soil Class Sod Color Comments Sod Color Test Hole #2 (EL= 103+) Depth Layer Soil Class Sod Color Comments Sod Color O 0"-8'1 O WATER SERVICE LINE I A/E Loa y Sand I OYR G/ I E B 9"-41 ° B Lo y Sand I OYR G/8 84"-140" 4 I" -G3" C I Me ium Sand I OYR GIG Perc @ GO" G3"-105" C2 5il Loam I OYR 7/2 Layer 105"-153° C3 Fm Sand a+ 2.5Y7/3 0"-G" U DATE OF TESTING: OG109199 SOIL EVALUATOR: DAVE MASON BOARD OF HEALTH AGE T: BRUCE MURPHY * AMY VON HONE, YARMOUTH HEALTH DEPT PERCOLATION RATE: LESS THAN 2 MIN/INCH IN "CI" LAYER NO GROUNDWATER EN OUNTERED { TEST HOLE LOGS Teat Hole #3 (EL= 107.lb±) EXISTING SPOT GRADE Depth Layer Soil Class Sod Color Comments 0"-8'1 O WATER SERVICE LINE I UNDERGROUND UTILITY LINES -E-E- 8"--V12" 12`-84' E B Loar Loa iy Sand y Fine Sand I OYR 5/3 I OYR 5/8 Perc @ 38" 84"-140" C I Me um Sand I OYR G/4 TEST HOLE LOCATION ±) Test Hole #4 (EL= l OG. Depth Layer Sod lass Soil Color Comments 0"-G" O ® CATCH BASIN 11% G"-1 O" E Loamy Sand I OYR 5/3 CONCRETE BOUND 1 O"-48" B Loamy Fine Sand I OYR 3/8 48"-90" C I Medium Sand 7.5YR 5/4 90"-144" C2 Silt lay Loam I OYR G/ 1 Mixed with Fine Sand DATE OF TESTING: 05/02/17 SOIL EVALUATOR: RON CADILLAC BOARD OF HEALTH AGE T: AMY VON HONE, YARMOUTH HEALTH DEPARTMENT PERCOLATION RATE: LE55 THAN G MIN/INCH IN "C" LAYER NO GROUNDWATER EN OUNTERED 1 MAP 151 PCL. 114 LOCUS Yarmouth, . MA MAP 151 PCL. 1172 �+ \ •� f TP -1 O \ / ILI 106. 100 105iOO-4' 5 1 - tK- 100 99 tK --97 -/ Yarmouth Health Department �. U, 97- b'1b 96V CABLE RISER 1 } NOT TO SCALE I .) .Assessor's Map 15 1 Parcel 118 2.) Deed Book 44G2 Page 08G 3.) Plan Book 330 Page I G 4.) This property is not in a Zone II of.a Public Water Supply 5.) Flood Zone: C LEGEND _3 EXISTING SPOT GRADE 24x5 PROPOSED SPOT GRADE -- EXISTING CONTOUR -24- PROPOSED CONTOUR w WATER SERVICE LINE u UNDERGROUND UTILITY LINES -E-E- UNDERGROUND ELECTRIC c GAS SERVICE LINE - t - TOP OF BANK a--o-o-- LIMIT Of WORK EDGE OF CLEARING -'-' T FENCE TEST HOLE LOCATION ST SEPTIC TANK DB DISTRIBUTION BOX SAS 501L ABSORPTION SYSTEM Reserve RESERVED FOR FUTURE USE CUJI UTILITY POLE ® CATCH BASIN 11% FIRE HYDRANT ® DRINKING WATER WELL CONCRETE BOUND ZONING: R-40 Lot Size: 40,000 5.F. Lot Frontage: 150' Setbacks: Front: 30' Side: 20' Rear: 20' Maximum Building Coverage: 25% Proposed Building Coveracje: 9% r.,yii� rj �-p r,llsa i0P it L HFAI T H 17""PT �" SN OF iy,A\ JOHN q� Z. DEMAREST, JR. No. 36859 �10 N. -0- 4.8 g5 \/l rvey By: 95 TRANSFORMER SITE PLAN 94 -�- '94 PHONE RISER j DEMAREST LAND SURVEYING � TOP OF BERM SCALE: I" = 20' 338 MAYFAIR ROAD ;,J-1, '---EDGE OF PAVEMENT SOUTH DENNIS, MA 02660 SYSTEM DESIGN CALCULATIONS 5EWA6EDE5/6N FLOWREQUIRED: 5 BEDROOM DWELLING Q { ! !0 GPD/BEDROOM = 550 GPD REOUIR50 1 5EWAGE DE51GN FLOW PROVIDED.• THIRTY F/VE (35) ADS UNITS IN BED CONFIGURATION. Vt = ((550/0.70)/(4.8 t-Tz/f7)/5.OLr7 = 32.7AD5 UN1T5 REQUIRED (35 PRO141DED) 588 GPD PROVIDED > 550 GPD REQU/RED 4 5EPTIC TANK CAPAC17YR50U1REDr 550 GPD X 200% _ / /00 GPD REQUIRED SEPT/C TANK CAPACITYPROVIDED: 1500 GALLON 5EPTIC TANK (M!N ALLOWfD) A GARBAGED/5P05AL /5 NOT PERM17Tf49 W1TH TH15 DESIGN FLOW INSPECTION NOTE: PRIOR TO FINAL INSPECTION BY THE ENGINEER, SYSTEM NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS. I o s9 LINDA J. tiN O CRONIN m F'O.L vim, "l s as y0c T;: 5k to I !• t l 0 20 40 GO I SCALE 1 "=20' C:\C5N\DT-Conway\DT-Conway-SD5 Plan,dwcg 508-364-9049 Proposed Site � Sewage Dlsp05al 5y5tem 10 Conway Dr., Yarmouth, MA Prepared for: CSN P.O. Box201 New Teixeira Residence Brewster, Mei 02631 :10 Damien t- Cyndi Teixeira 23 Harlow Rd. Phone: (508) 274-7347 Sandwich, MA 025@3 ENGINEERING DATE: SCALE: DESIGN: CHECK: JOB NO: 04/09/18 1 A5 SHOWN I Lip I KM 2018100