HomeMy WebLinkAboutReview Checklist i' -'(g TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. f g` Lot III Zone of Contribution: In Out A`r creage Commercial: Residential: C------Street: 76 Ae4,1a kA Village: Floor Plan: ✓ #Bedrooms: 11 ' Owner: 444 t 4l,� agev-g_ Installer: J 7'P i fic5; Address:231,(424 /, Phone: IO Phone: ,j C SA/ � � Builder: Engineer: ii(" 7 Address: Phone: a ti i . /if ,..,:...----.27� Phone: p / 4. ' 4 i N/A -, NO 1.Required# of copies received 2.Date of soils exam and percolation test not older than 2 years � 3.4-5 ft of naturally occurring pervious material,above water table `�..:---y` 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ....i'` 5.Water line 10 ft from septic components Var.: �r--- 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: :.-/ _ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ....---- 9.Leaching minimum 100 ft from wetlands Var.: i ---- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 1---- - 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: t_.---- 13.Uses adjustment for maximum high groundwater Var.: C../ 14.Leaching set 4-5 ft above adj.water or botto.' . ' est io `1', Var.: \---- -- 15. `„/15. System not in top or subsoil(A,B horizons or 5' remov. i-------- 16.Proposed contours are suitable L------ 17. f-�17. System meets slope requirements-min. 1/8", '/4"preferred k.--- 18. 18. System meets breakout requirements PVC linertj e, j Wall: k....----- 19. Specified tee sizes are proper, gas baffle on outlet tee ' t.------ 20. --�20. Sewage is under 10,000 gpd for parcel k.--- 21.No garbage disposal c_..---' 22. System adequately sized for its intended use 4 _23.Minimum 6"stone or compacted below tank and dbox `/ 24.Manhole covers within 6"of grade,pump chamber cover to grade L-.--- 25. /25.Inspection port on plastic chambers/leach field L---- 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size ..____-_'' 28. Septic tank/pump chamber to be factory waterproofed .------ 29.Vent provided if leaching below 3 feet,under driveway/parking ✓'' 30.Buoyancy calculations for tank/pump chamberi'---' 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓----- 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee,installer signature ------ 35. /35.Foundation footing min. 2 feet above adjusted ground water for new house '.......---- 36. --36.Deed Restriction required max. #bedrooms: max. flow: gpd 't.__.----' 37.Check area lots for groundwater/Label groundwater in Assessor's `._ r� -J Plan reviewed by: l� 6/03/03