HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 91 Lot a r 3 Zone of Contribution: In Out ✓ Acreage
I Commercial: Residential: 1/
Street: 3 C eve, vi Cw 1,n ve,
village: S a,n.i 'Lfw....-c Floor Plan: V #Bedrooms:
Owner An ityni 0 4 12‘101:, COSH Installer ?
Address: -'' Phone:
Phone:
Builder: Engineer: ,Qa n C4 e 1//4C.
Address: Phone: 50 3- 7-7S---. 9 70 O
Phone:
WA YES , NO
1.Required#of copies received >
2.Date of soils exam and percolation test not older than 2 years -3--u1 kit
�/
3.4-5 ft of naturally occurring pervious material,above water table (t.5 v
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: I/
5.Water line 10 ft from septic components Var.: Vi
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: 6,std 1060 6411. ./
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: "AS'i,L v"'
9.Leaching minimum 100 ft from wetlands Var.: /
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t/
11.Tank/leaching minimum 10 ft from property line Var.: /p i tr.
12. System meets all other setback requirements Var.: V
13.Uses adjustment for maximum high groundwater Var.: 1/
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: Co .5' V
15. System not in top or subsoil(A,B horizons)or 5'removal 6/-
16.Proposed contours are suitable kr
17. System meets slope requirements-min. 1/8", Y4"preferred A/'
18. System meets breakout requirements PVC liner Wall: t/ V
19. Specified tee sizes are proper,gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel yi 1 (Pet) ]/
21.No garbage disposal
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox �'
24.Manhole covers within 6"of grade,pump chamber cover to grade V
25.Inspection port on plastic chambers/leach field /
26.Electrical permit for pump chamber/Separate meter for duplexes ✓
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size i/
28. Septic tank/pump chamber to be factory waterproofed V
29.Vent provided if leaching below 3 feet,under driveway/parking V
30.Buoyancy calculations for tank/pump chamber f
31.Engineer to inspect and certify soils: wall: commercial: ,�
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature /
33.H-20 loading is subject to vehicular traffic, groundwater /
34.Title V Application and permit fee, installer signature () --
35.Foundation footing min.2 feet above adjusted ground water for new house I
36.Deed Restriction required max. #bedrooms: max. flow: gpd , t/
37.Check area lots for groundwater/Label groundwater in Assessor's Map ''
Plan reviewed by: Cl 6i r 9 a4 6/03/03