Loading...
HomeMy WebLinkAboutReview Checklist :-rte ( iy TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot Zone of Contribution: In Out /Acreage Commercial: Residential: L Street: /7/ CAocoveJ/ /264 Village: 4/&s/-- Yom,,,,,„ff,, Floor Plan: #Bedrooms: 'V Owner: /ealard 1- 7?rte/ 7J „-4 Installer: 5Ore n tx<Gu/fes f' Address: 7$ 4.:,..4e_127 /eat! btayev:14 40( Phone: Se 'I 5!?dt5 Phone: Builder: Engineer: C'Ga_s*/ i*-/e77 Address: Phone: ,a;)9, Q515-6. j Phone: N/A YES NO 1.Required#of copies received ✓ 2.Date of soils exam and percolation test not older than 2 years Sea 1-e0- V l� 3.4-5 ft of naturally occurring pervious material,above water table ,V 4.Foundation 2 ft above high point of road . H.P.: Fnd: Var.: V 5.Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 1, 7. Septic tank minimum 10 ft from foundation, deck Var.: 4, _ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ✓ 9.Leaching minimum 100 ft from wetlands Var.: V 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: V 12. System meets all other setback requirements Var.: V 13.Uses adjustment for maximum high groundwater Var.: 17 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15.System not in top or subsoil(A,B horizons) or 5'removal ✓ 16.Proposed contours are suitable ✓ 17.System meets slope requirements-min. 1/8", 1/4"preferred ,✓ 18. System meets breakout requirements PVC liner: Wall: ✓ 19. Specified tee sizes are proper, gas baffle on outlet tee V 20. Sewage is under 10,000 gpd for parcel ,✓ 21.No garbage disposal V 22. System adequately sized for its intended use ✓ 23.Minimum 6"stone or compacted below tank and dbox V 24.Manhole covers within 6"of grade,pump chamber cover to grade z 25.Inspection port on plastic chambers/leach field ✓ 26.Electrical permit for pump chamber/Separate meter for duplexes V/ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓ 28. Septic tank/pump chamber to be factory waterproofed V 29.Vent provided if leaching below 3 feet, under driveway/parking V 30.Buoyancy calculations for tank/pump chamber ./ 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓ 33.H-20 loading is subject to vehicular traffic, groundwater ✓, 34.Title V Application and permit fee,installer signature ✓ - 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd- ✓ 37.Check area lots for grouudwater/Label groundwater in Assessor's Map Plan reviewed by: N I iI 2.I T 6/03/03