HomeMy WebLinkAboutElevation Ceritificate HOME ENERGY RATERS L LC
BUILDING PERFORMANCE TESTING
Air Leakage Report
130 South Shore Drive Test Mode 1)( % 8 /1 i
Yarmouth Depressurization
Test Pressure
09/23/2019
50.0 Pascals
George Davis
Test Equipment
2015 IECC Energy Code Minneapolis
Total Air Leakage or Air Changes Per Hour Gauge
511 1.93 $4
Conditioned Volume
15917
This project meets the criteria for the following:
2009 International Energy Conservation Code
2012 International Energy Conservation Code
2015 International Energy Conservation Code
180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM
powered byyocarwas www.gocanvas.com 3DDD77AD-4A6F-4A0C-B39D-EA86ABE85BC8
HOME ENERGY RATERS L LC
BUILDING PERFORMANCE TESTING
Ventilation Report
Ventilation Tests
1st Floor Common Bathroom 55 IOW
ob soda►
shoes owe
„L
r,•
2nd Floor Bathroom 69 •
Mal
130 SoOTl1
Shag,bows
•
♦1f I
180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM
powered by goconvos www.gocanvas.com 3DDD77AD-4A6F-4AOC-B39D-EA86ABE858C8
•• HOME ENERGY RATERS L LC
BUILDING PERFORMANCE TESTING
Compliance Option S1:
Follow these steps to determine compliance for the fan Airflow.
1) Determine the floor area of the conditioned space of the home=(.a )
2) Determine number of Bedrooms.(Ja+r)
3) Insert these number in the formula Below:
Fan airflow(CFM)=0.01Anoor+7.5(Na+1)
Fan Airflow for Homes with Average Air Leakage
Floor Area(ft2) No.Of Bedrooms
0-1 2-3 4-5 6-7 >7
<1500 30 45 60 75 90
1501-3000 45 60 75 90 105
3001-4500 60 75 90 105 120
4501-6000 75 90 105 120 135
6001-7500 90 105 120 135 150
>7500 105 120 135 150 165
Fan airflow is CFM.
Chris Mazzola
RTIN# 8873503
180 STATE ROAD SUITE 2U SAGAMORE BEACH,MA 02562-(508)833-3100-ENERGYCODEHELP.COM-INFO@ENERGYCODEHELP.COM