Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Cerci Lot `/ Zone of Contribution: In OutAcreage Commercial: Residential: �o Street: /a 4,/ L!6/l.,( Village: ii Floor Plan: #Bedrooms: 2 / Owner: 1- 1°23 Installer: �`Z /42t0.5 f Address: Phone: a 2- 6*3 Phone: Builder:. Engineer: T Address: Phone: �--241C- Phone: N/A YES .`ISO 1. Required#ofcopies received _ :., ,� 2. Date;of soils exam and percolation test not older than 2,years r, 3./4-5 ft of naturally occurring pervious material,above water , , watertable -" L/r 4. Foundation 2 ft above high point of road H Pf Fnd: ,Var.: 5.Water line 10 ft from septic components Var.: ., 6. Benchmark indicated and shown-NGVD if near wetlands ,,;r,. 7. Septic tank minimum 10 ft from foundation,deck = ; , 1, .- .; " ""-- u... 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab 5 V4k 9. Leaching minimum 100 ft from wetlands , 10. Leaching minimum 150 ft from drinking well/251ft irrigation well 11Tank/leaching minimum 10,ft from property line- Var. 2 , fc e( ` a� s 12. System meets all,.other setback requirements Var. -- 13.Uses adjustment for.maximum.:high groundwater Vara. , 14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15. System not in top or,subsoil(A,B horizons) or 5'removalt/ �'" 16.Proposed contours.are;suitablu . .. ,_- , ..x.17:System meets slope requirements-min.,1/8',, '4"preferred u:. ,t 18. System meets breakout requirements PVC liner: ° . Wall:, • - ,; 19. Specified tee sizes,are.proper,gas baffle on outlet tee , 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal _ 22. System adequately sized for its intended use , > F a rr . 23.Minimum 6"stone or compacted below tank-and dbox o- - ; , :t 24.Manhole covers.within6",of grade,pump chamber cover to grade � 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"l ;weep,hole,ch eck valve,tee in dbox,pump.size 28. Septic tank/ a t ep pump camber to be factory waterproofed -� 29.Vent provided if leaching below 3 feet,under driveway/parking=. .. ., 30. Buoyancy calculationsfor tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: 1., ✓ 4',..,,,x 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature .,, ,. 33.H-20 loading is subject to vehicular traffic,groundwater C./ 34.Title V Application:andpermit fee, installer signature L/ 35.Foundation footing min. 2 feet above adjusted ground water for new house :./ 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: (__ \ 03