Loading...
HomeMy WebLinkAboutReview Checklist , TOWN OF YARMOUTH SEWAGE/PLAN REVIEW CHECKLIST Location: A.M. r Lot I)0 Zone of Contribution: Inj Out_ Acreage 12/ 34/C.F � � r Commercial: Residential: X p Street: . A-0-4,-- Vv3 ali Village: Floor Plan: #Bedrooms: Owner: 014)4 1-61 Ind✓Lf SS4 Installer: 12D 1. DuX Address: Phone: Phone: Builder: Engineer: 4t S Ri\/L✓ - Tc - 114°--1-41t14-v' Address: Phone: Phone: N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years t./--- 3.4-5 /'3.4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓' 5.Water line 10 ft from septic components Var.: 1/ 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ,.---- _ 9.Leaching minimum 100 ft from wetlands Var.: J. ✓� 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t- 11.Tanklleaching minimum 10 ft from property line Var.: t . 12. System meets all other setback requirements Var.: s ' 13.Uses adjustment for maximum high groundwater Var.: ,- • 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: t 15. System not in top or subsoil(A,B horizons)or 5'removal t . 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 'A"preferred •✓ 18. System meets breakout requirements PVC liner: Wall: 1/- 19. Specified tee sizes are proper, gas baffle on outlet tee 20.Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use i,------ 23. 23.Minimum 6"stone or compacted below tank and dbox ,/- 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes t/ 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: ,/ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature t/-"-- 35. '35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. 3 #bedrooms: max. flow: laft gpd 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: ���ti�'" i7 6/03/03