Loading...
HomeMy WebLinkAboutEngineered Plan - 2020LOCUS—) I - \ II 25.0' LOCATION MAP MAP .............. LOT 40 (12,349 SF)• • • • .. • . • ASSESSORS MAP: 89 PARCEL: 16 N LAND COURT CASE 31209D LEACH AREA DETAIL I �c 99 1 98 M20-03 BENCHMARK AT CONCRETE BOUND ELEVATION = 99.36 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' EFF. DEPTH) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAL/DAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAL/DAY CAPACITY = 349 GAL/DAY ; SEPTIC SYSTEM SECTION BED BATH KITCHEN I DINING ROOM BATH , ROOM TION _EV. ✓ 1 buu GAL SEPTIC TANK (6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN BED BED LIVING ROOM ROOM ROOM GARAGE I EXISTING FLOOR PLAN I Permit valid for REPAIR OF SEPTIC SY ONLY, due to State and Local septic var Board of Ilcalth Iv�iew and approval is redui any future allJltions/renovations/alteratio sewage facilities and/or structures/dwelling. Yannlntth Ilealth Department APPROVED TERR ANIv �, WARN' No. 38721 p- MAX. 1/4" per ft COVER ift(1' MIN) 8 /7[_T -F 1/8"per ft D -BOX " MECHANICALLY COMPACOTED) J 6.0 ELEV. -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS MCLELLAN, P.E. WITNESS: MALORY LANGLER, R.S. DATE: 2-13-20 PERCOLATION RATE: < 2 MIN/IN 2" PEASTONE OR FILTER FABRIC - 3/4" -1 1/2" DOUBLE 7W HED STONE INSPECTION PORT �- ELEV.= 96.83 Wal I* °°°°°°°° °I'lMd 94.0 4 4 ELEV. 25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' EFF. DEPTH) TH-1 100.0 — I ELEV. 0/A HORIZON LOAMY SAND 10YR 4/1 98.2 B HORIZON LOAMY SAND PERC AT 36" 10YR 5/8 C HORIZON MEDIUM SAND 2.5Y 7/4 132"1 1 89.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. _15-2IPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). RST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. ices. I IbrT AE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. e.OALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL C' DE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. ROUND COVER OVERALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. IELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE — PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. KEY: EXISTING CONTOUR: - — — - �1•f PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 m PROPOSED SPOT ELEVATION: 25.5 y TEST HOLE: * UTILITY POLE: -o- FENCE LINE: HYDRANT: -6-- { T RETAINING WALL: o LOCUS—) I - \ II 25.0' LOCATION MAP MAP .............. LOT 40 (12,349 SF)• • • • .. • . • ASSESSORS MAP: 89 PARCEL: 16 N LAND COURT CASE 31209D LEACH AREA DETAIL I �c 99 1 98 M20-03 BENCHMARK AT CONCRETE BOUND ELEVATION = 99.36 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' EFF. DEPTH) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAL/DAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAL/DAY CAPACITY = 349 GAL/DAY ; SEPTIC SYSTEM SECTION BED BATH KITCHEN I DINING ROOM BATH , ROOM TION _EV. ✓ 1 buu GAL SEPTIC TANK (6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN BED BED LIVING ROOM ROOM ROOM GARAGE I EXISTING FLOOR PLAN I Permit valid for REPAIR OF SEPTIC SY ONLY, due to State and Local septic var Board of Ilcalth Iv�iew and approval is redui any future allJltions/renovations/alteratio sewage facilities and/or structures/dwelling. Yannlntth Ilealth Department APPROVED TERR ANIv �, WARN' No. 38721 p- MAX. 1/4" per ft COVER ift(1' MIN) 8 /7[_T -F 1/8"per ft D -BOX " MECHANICALLY COMPACOTED) J 6.0 ELEV. -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS MCLELLAN, P.E. WITNESS: MALORY LANGLER, R.S. DATE: 2-13-20 PERCOLATION RATE: < 2 MIN/IN 2" PEASTONE OR FILTER FABRIC - 3/4" -1 1/2" DOUBLE 7W HED STONE INSPECTION PORT �- ELEV.= 96.83 Wal I* °°°°°°°° °I'lMd 94.0 4 4 ELEV. 25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' EFF. DEPTH) TH-1 100.0 — I ELEV. 0/A HORIZON LOAMY SAND 10YR 4/1 98.2 B HORIZON LOAMY SAND PERC AT 36" 10YR 5/8 C HORIZON MEDIUM SAND 2.5Y 7/4 132"1 1 89.0 NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. _15-2IPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). RST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. ices. I IbrT AE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. e.OALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL C' DE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. ROUND COVER OVERALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. IELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE — PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. THOkiA8 J. u, lt:^,CLELLAN ea v CIVIL c-'„ No. 36471 J IST NAL et`' SITE PLAN LOCATION: 69 ASTOR WAY, S. YARMOUTH, MA PREPARED FOR: EDWARD MORASSI DATE: 2-14-20 SCALE: 1" = 20' BASS RIVER ENGINEERING i P E P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048 �1•f i 6 1 W�yi 1'I t , THOkiA8 J. u, lt:^,CLELLAN ea v CIVIL c-'„ No. 36471 J IST NAL et`' SITE PLAN LOCATION: 69 ASTOR WAY, S. YARMOUTH, MA PREPARED FOR: EDWARD MORASSI DATE: 2-14-20 SCALE: 1" = 20' BASS RIVER ENGINEERING i P E P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048