Loading...
HomeMy WebLinkAboutSite Plan Review - 2-18-2020LEGEN D - 99 - EXISTING CONTOUR X 99�r EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR �98�4] PROPOSED SPOT EL. TH1 � TEST HOLE 2� SLOPE OF GROUND �Q� UTILIN POLE F RE HYDRANT � I Y NOTE: NOT ALL SYMBOlS MAY MPEAR IN DF #143 MAP 122 PARCEL 128 VALERIE GRANT DB 29469 PAGE 236 z 0 a N av IDCE #�8-4zz #153 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 1 BEDROOMS � 110 GPD = 110 GPD 2050 S.F. RETAIL � 50 GPD/1000 SF = 103 GPD USE A 213 GPD DESIGN FLOW SEPTIC TANK: 213 GPD (2) = 426 USE A 1500 GAL. DUAL COMPARTMENT SEPTIC TANK USE A 1000 GAL. GREASE TRAP FOR KITCHEN FLOW LEACHING: = 9 6 SF PER HIGH 4.73 SF LF x 6.25 LENGTH 2 .5 � RATOR UNIT CAPACITY INFILT 213 GPD/0.74 GPD/SF = 288 SF LEACHING REQ'D 288 SF/29.56 SF/UNIT = 10 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (10) H-20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION OF 2 ROWS OF 5 UNITS 10 UNITS x 29.5 SF = 295 SF > 288 SF 295 SF (0.74) = 218 GPD (OK) , MA APPROVED DATE BOARD OF HEALTH ------ � � - #153 SYSTEM PROFILE (NOT TO SCALE) � 2' CAST IRON COVERS TO GRADE OR CONCRETE 2' CAST IROd CNERS TO GRA�E OR CONCREfE ALL SYSTEM COMPONENTS SHALL BE COVERS TO WITHIN 6" GR4DE, COORDINATE W/ OWNER COVERS TO WRHN 6" GRADE, COORDINATE W/ OWNER MARKED WITH MAGNETIC TAPE OR COMPAR4BLE MEANS FOR FUTURE LOCATION. 46.0' 46.1 ' 47.0' IvININUM .75� OF COVER OVER PROVIDE INSPECTION PORTS TO 44.83 44.53� a' uiN. SuntP 4"0SCH40 PVC � Wll?iIN 3" OF FINISH GRADE :� .,,, t2' �+iN. iNi. oiu. PIPES LEVEL 1ST 2' , 43.0 *44.0 ao• io- ia• ��, ; NOTE: TWO SEPTIC PIPES 43��8, �• TEE 43.48� � TEE 2a. � TEE 43.23� - FROM BUIL�ING REQUIRED; GAS BaFFLE ���.. ' "aogogogog000 WATERTEST D'BOX 43.53 cas enFF�e :� '-°���°•°�°-• FOR LEVELNESS . �. ..90 GAL H-20 .. 1500 GAL H-20 i ` . ' �I ' GREASE TRAP 12�� .� 4� Lp. LEVEL ' 4.'2.9Z' 42J5 '�, ''�}�',; SEPTIC TANK {: qCM! OR EOUAL .; :.r :? Joo'o� , .. .. ^ .. .. ,,. _ ;: .o.o.�: . ,. :o.Q;o`` o +o�o, .. ..:.00.�..o'�o 0 0 0 �• Vo �o��� � � o�o � , o 0 000000000°0°0°0�0°0�0 0 0°0°0°0�0 0 0 0 "o°o 0 0°0°0°0 0 0 . o°do 0 0°0�0 oa000^000,0000ao^oo,00000000000000e0000,000,o o,o,0000a,o,^,00^0000000aoo,eo;0000,^oo,000,o �THE INSTALLER SHALL VERIFI' THE LOCATIONS - o.o o , o�o,n_ .,. o 0 0 o n o. __..n.o 0 OF ALL UTILITIES AND ALL BUILDING SEWER 6" CRUSHED STONE OR MECHANICAL # OUTLETS AND ELEVATIONS PRIOR TO INSTALLING COMPACTION. (15.221 [2]) L� 6" CRUSHED STONE OR MECHANICAL � ANY PORTION OF SEPTIC SYSTEM �COIAPACTION. (15.221 [2]) NOTE: TWO SEPTIC PIPES FROM BUILDING REQUIRED; SEPTIC PIPE FROM BUILDING TO GREASE TR4P FOR KITCHEN � WASTE ONLY SEPTIC PIPE FROM BUILDING ( 2'2% SLOPE) Q 5 42.67' o.s2' 41.67' USE (10) HIGH CAPACITY INFILTRATORS IN CONfl6UR4TI0N SHOWN (NO STONE PROPOSED) 7.97' ADJUSTED GROUNDWATER EL. 33.7' TO SEPTIC TANK FOR SANITARY WASTE ONLY. (_� SLOPE) ( 1 y, SLOPE) ( � 7. SLOPE) FOUNDATION ��� GREASE TRAP -1' I SEPTIC TANK ?3' D' BOX 8' - -21 ' � ( �'5� SLOPE) i � 43 / � �( � �g¢� �� 3/ BENCHMARK: 3 D MAG NAIL ol � _� �I =43.8' NAVD88 (VARIABLE WIDTH STATE HIGHWAY) � � w >/ �. o/ GRANITE CURB 0 � 24" OAK I ! � MAG qSPHALT SIDEWALK ' ASPHALT SIDEWALK SET _ 30.02� 24" OAK N88'13�58"E 10.37�� g �' 9.75' _OVE_ANG_ A 4 � DECK A 6.07' � � 3.7�' � � � ���� � o ' a I � INAHO MAP 122 PARCEL 127 #i4� 2.45 O N EXISTING m BUILDING TOF=45.1 / #153 MAP 722 PARCEL 126 �S / L/ , � N 1 RESTAURANT #i5� % #; 1 �3 � __ _� _._- --- -- Yy � 1 � � ,- T/^ �., r� '' � ��--...fl/� `�`�...^''.''.�� i/ _-___----- ; �.____- � �-- - --- � � ,_ { "�L�L1-./ (J � ,��� , _ i �� �/ J � C7 � � � ��� �; �' ', �;� ����� �� �� BENCHMARK: � n MAG NAIL � r =43.8' NAVD88 ' �' �p ; (y� qR�qgLE WIDTH STATE HIGHWAY) �/ �' � RIM 43.4 �./.."�, � f c,f INV. 39.4 ,---,f� o� cRn!v�"rE cuR� _-� M H'4� RIM 43.0 INV. 39.7 CB� RIM 42.8 INV. 39.8 . x !�.fi� '22 PA!'�cL 12t3 ( V,ii�£R€E �P,�NT � G�r 29464� [�;,C,t 235 } � F Y w N N U W � EXISTING ASPHALT PARKING , MAP 122 PARC L 125 ALOA M. & YUTI ATANABE DB 8177 P 250' '� EXISTING CONDITIONS 0 �, � � �rG �Rt1 24.. � �: � z� ��t :� � � ,;� r ; Y��`� iL_T,..( �,� / ` �` � � ... . ` � .. � �,� LP2 i ,�� RIM 43.5 � � INV. 39.4 1 � � 7 � c� 20' 20' � 46 Z 0 &ikP ]22 �AKC�� 121 #14i ASa..- � �:C�4';ALK� SGT . ASPHA�T SICESVALK � � - - ��--� - �- ".�-_� � p � � n �~ OVERHANG�/'�� r-4-� " } � / __ oE�K ?`��:��} i i � i,I ' I ol J i � � ,_� , �r,5 i ol' �� [ 0 N EXISTING m BUILDING �TOF=45.1 � / ;153 �AA? '22 i >��c�� �zs v r� 0 0 � ri INAHO RESTAURANT �`,� i 57 \c's j r ��"cp `1� � / � y nwi \ � � U � � Q' .� � n I w � ,� O-�.! /Q \-./ ``L`� K C7 I j Z .. .. J '=��� � d ( cv �` I � � � � � � ��- � �� � '�, , j m i s r �� � � I ���. � �_�.X______ �� � , ° .� � ��-�..�_� � � W� � �� � J J ( �o � � � , � ��~�� ¢ I � N I � � `"���� w I EXISTING T�REE TO REMAIN ',�� �, � � 3 I CONSBRkiCT(ON CTED DURIN� �� �-.- � � `��" co o � � � � -�a � ��,r� N m � s' ��} I �"� 5'� REMOVAL OF UN§UITABLE SOIL REQUIRED � j ��'t"`� I � j A�20UND PERIMETER"OF LEACHING FACILITY, j` i a {��: I � E D WN TO SUITABL�-SOIL LAYER. REPLACE �- �f €� iH CLEAN MED. SAND, TO MEET � � �ECIFICATIONS OF� 310 CMR 15.255(3) � I � � �� r ;� � �; . � � E t�ki>r:Ea ,� � G'=' ` � `�, � RSE'i IRLi ``I ��� 1� �� � w � Pf� ��41�lG �.„ ..0' ? PROP. VENT N1TH CHARCOAL FILiER 3� h � AND BUGSCREEN (FINAL PLACEMENT BY � � / �� CON7RACTOR VATH HOMEOWNER r4Br � � CONSULTATION) �'. �� 32�� � � t��A�' 122 PAR�E 125 2g � E l. � � A�DA M. � YiiTi b' h7At�kS� 59' `ti �. ��B �177 Y�s� 2�6 PROPOSED CONDITIONS � FACILITY 4" SCH40 VENT WITH CHARCOAL FILTER AS SHOWN PLAN VIEW PITCH BACK TO SAS, NO LOW POINTS. VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405 1b: SAS TO BE > 3' BUT z 6' BELOW FINISH GRADI NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER F00T. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-24 5. PIPE JOINTS TO BE MADE WATERIIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. 1}i15 PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSiEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPEC110N BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5� AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. TEST HOLE LOGS 1-2 ENGINEER: DARREN MEYER, CSE 1614 WITNESS: AMY VON HONE, RS DATE: 12/21/2017 PERC. RATE _ < 2 MIN/INCH CLASS � SOILS ELEV. ELEV. O TP-1 46.6� Q" �-2 47.2' A A LS L5 - 10YR 3/2 10YR 3/2 8° 12" 8 B LS LS _ 39„ 10YR 5/8 43.3� 40�� 10YR 5/8 43.9� �, �, SiL SiL I\ I Dennis � Pond L� LOCUS MAP SCALE 1"=2000'f ASSESSORS MAP 122 PARCEL 126 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001C0559J DATED 7/16/2014 ZONING SUMMARY #153 ZONING DISTRICT: B-1 BUSINESS DISTRICT REQUIRED: MIN. LOT SIZE 25,000 S.F. MIN. LOT fRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 25' MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% MAX. LOT COVERAGE 70� OWNER OF RECORD TATIBOUET GROUP ATLANTIC LLC 2929 PONNI M01 ROAD HONOLULU HAWAII 96815 REFERENCES DEED BOOK 32347 PAGE 119 PLAN BOOK 200 PAGE 49 PARKING CALCULATIONS: MERCANTILE: 35 OCCUPANTS (1/7 OCCUPANTS) = 5 SPACES REQ. RESIDENTIAL• ONE UNIT (2/UNIT) = 2 SPACES REQ. TOTAL: 7 SPACES REQUIRED 7 SPACES PROVIDED INCLUDING 1 HANDICAP (5 SPACES PROVIDED ON ABUTTING PROPERTY PER WRITTEN AGREEMENT) , y I :,� I P I.. � i� ,�..��,�, I �I u I��•�, 1�,.'�.wilMi� II�!�� � #�153 F�OUT� 6A YARMOUTH POi�T, I�A PREPARED FOR TATIBOUET GF�OIJP' 156" 2•5Y 7/4 33.6� 154» 2•5Y 7/4 32 4, ATLANTIC LLC siEve C2 C2 DATE: JANUARY 29, 2020 CS CS Scale:l "= 20' SILT POCKETS SILT POCKETS L s � � i 2.5Y 7/4 2.5Y 7/4 G-W ADJ. DATA: a �0 20 3o ao so FEEr 204" 30� 204° 30.2' WELL: AIW-247 _ ZONE: B ADJ: 2.9� off 508-362-4541 GROUNDWATER ENCOUNTERED 190" EL. 30.8 DECEMBER 2017 I foX 5o8-3sz-esao �,�.c,rthr�,y,� downcape.com OO �,: --� �,s �+,'���Or1�,qSS��,� • • iv,Qr,�E�_A -��,� down cape engineering, inc. � o��°•��� ��+'� civil engineers `�'"�� "�� land su�veyors ��o. a0002 % �'��� 939 Moin St�eet Rte 6A ��,s ��e%: i � ;;s � E �� � ,� � �„ � YARMOUTHPORT MA 02675 a������, �. PERMIT SET NOT FOR CONSTUCTION 2020.DWG