Loading...
HomeMy WebLinkAboutInspection Report 2020 Mar 16 Pia?' ' Commonwealth of Massachusetts a/ ELggLE LU Title 5 Official Inspection Form MAR 2 0 2020 Subsurface Sewage Disposal System Form -Not for Voluntary Assessments HEALTH DEPT. 19 Bradford Road, West Yarmouth, MA Property Address x 4 "'0. Voskanian Shaunt 73 Williston Road 0V07/Z02n paOR'io ar.f 110 A Owner Owner's Name ftc)}t.TW Derr. 'What) information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important:When A. Inspector Information filling out forms on the computer, Armando Pantoja use only the tab key to move your Name of Inspector cursor-do not Accu Sepcheck use the return Company Name key. 17 Northside Drive ' �� Company Address South Dennis MA 02660 City/Town State Zip Code :dun 508-385-5891 SI 14296 Telephone Number License Number B. Certification I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5 (310 CMR 15.000); I have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems.After conducting this inspection I have determined that the system: 1. ►./ Passes 2. ❑ Conditionally Passes 3. ❑ Needs Further Evaluation by the Local Approving Authority 4. ❑ Fails ,t.*1 4 3/17/2020 Inspector's Signature G��� Date The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note: This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 1 of 18 • Commonwealth of Massachusetts r -- 1F Title 5 Official Inspection Form Alf1 Subsurface Sewage Disposal System Form -Not for Voluntary Assessments c tnr 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection C. Inspection Summary Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6. 1) System Passes: / I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist.Any failure criteria not evaluated are indicated below. Comments: 2) System Conditionally Passes: • ❑ One or more system components as described in the "Conditional Pass" -ection need to be replaced or repaired. The system, upon completion of the replaceme' or repair, as approved by the Board of Health,will pass. Check the box for"yes", "no"or"not determined" (Yii-t(N, ND) for following statements. If"not determined," please explain. The septic tank is metal and over 20 years old*or the ' •tic tank(whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltratio. •r tank failure is imminent. System will pass inspection if the existing tank is replaced with a c• plying septic tank as approved by the Board of Health. *A metal septic tank will pass inspectio it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is -ss than 20 years old is available. El Y ❑ N ❑ I D (Explain below): t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 19 Bradford Road, West Yarmouth,MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) 2) System Conditionally Passes (cont.): ❑ Pump Chamber pumps/alarms not operational. System will pass with Boa • if Health approval if pumps/alarms are repaired. ❑ Observation of sewage backup or break out or high static wa - level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled • uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s) are replaced AR/ / Y ❑ N ElND (Explain below): obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): El distribution box is leveled or rep ed ❑ Y ❑ N ❑ ND (Explain below): ❑ The system require• pumping more than 4 times a year due to broken or obst • ed pipe(s). The system will pass i pection if(with approval of the Board of Health): ❑ broken •ipe(s) are replaced ❑ Y ❑ N ❑ ND plain below): ❑ ob uction is removed ❑ Y ❑ N W ND (Explain below): 3) Further Evaluation is Required by the Board o 'ealth: ❑ Conditions exist which require further eva -tion by the Board of Health in order to determine if the system is failing to protect public he h, safety or the environment. a. System will pass unless Boar• if Health determines in accordance with 310 CMR 15.303(1)(b)that the system is ' •t functioning in a manner which will protect public health, safety and the environment: t5insp.doe•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 18 • • c Commonwealth of Massachusetts , ( Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ir �, ,Iii --;.--...) ' di 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a sa arsh b. System will fail unless the Board of Health (and Public Water Suppli , if any) determines that the system is functioning in a manner that protects t• public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS .nd the SAS is within 100 feet of a surface water supply or tributary to a surface water .upply. E l The system has a septic tank and SAS and the SAS is wi in a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS *,. within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the -AS is less than 100 feet but 50 feet or more from a private water supply well**. , I . Method used to determine distance: **This system passes if the well water an. s, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and t presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that n• other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must indicate"Yes"or"No"to each of the following for all inspections: Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form.Subsurface Sewage Disposal System•Page 4 of 18 • Commonwealth of Massachusetts _QF. Title 5 Official Inspection Form I. == - )) Subsurface Sewage Disposal System Form -Not for Voluntary Assessments %Ilk1>fi 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than %day flow ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: . ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis and chain of custody must be attached to this form.] ❑ 1 The system is a cesspool serving a facility with a design flow of 2000 gpd- 10,000 gpd. ❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems: To be considered a large system the system must se - . facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes"or"no"to each of - following, in addition to the questions in Section C.4. if Yes No ❑ ❑ the system is within 400 f-- of a surface drinking water supply ❑ ❑ the system is with', 00 feet of a tributary to a surface drinking water supply ❑ ❑ the system i • ated in a nitrogen sensitive area (Interim Wellhead Protection Area— I ''A) or a mapped Zone II of a public water supply well t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 18 • Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form Not for Voluntary Assessments 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) If you have answered "yes"to any question in Section C.5 the system is considered a significant threat, or answered "yes"to any question in Section C.4 above the large system has failed. The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section C.4 shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6. You must indicate "yes" or"no"for each of the following for all inspections: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ►1 Were any of the system components pumped out in the previous two weeks? ►� ❑ Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined? (If they were not available note as N/A) /. ❑ Was the facility or dwelling inspected for signs of sewage back up? ►Z� El Was the site inspected for signs of Ad' out? ►Z� ElWere all system components, esu+ Ing the SAS, located on site? /ZI ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? Was the facility owner(and occupants if different from owner) provided with ® ❑ information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ❑ Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] t5insp.doc•rev.7/26t2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 18 Commonwealth of Massachusetts F Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments Virvi 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information 1. Residential Flow Conditions: Number of bedrooms (design): 3 Number of bedrooms (actual): 3 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330 GPD Description: 1500 G SEPTIC TANK, DBOX AND 4 HIGH CAPACITY INFILTRATOR CHAMBERS W 4'STONE ENDS, 2' SIDES AND 1'UNDER. 2 Number of current residents: Does residence have a garbage grinder? ❑ Yes ►1 No Does residence have a water treatment unit? ❑ Yes ® No If yes, discharges to: Is laundry on a separate sewage system?(Include laundry system inspection El Yes /5 No information in this report.) Laundry system inspected? ❑ Yes El No Seasonal use? /1 Yes ❑ No Water meter readings, if available (last 2 years usage (gpd)): 167 GPD Detail: 2019: 66,000 G ; 2018: 56,000 G Sump pump? El Yes ® No Last date of occupancy: CURRENT Date t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 18 cam, Commonwealth of Massachusetts - ; F Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 2. Commercial/Industrial Flow Conditions: Type of Establishment: Design flow (based on 310 CMR 15.203): '.allons per day(gpd) Basis of design flow (seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ® No Water treatment unit present? El Yes ® No If yes, discharges to: Industrial waste holding tank present? ❑ Yes ® No Non-sanitary waste discharged to e Title 5 system? ❑ Yes ►/ No Water meter readings, if avail. e: Last date of occupancy/u : Date / Other(describe belo . 3. Pumping Records: Source of information: PUMPED 6/2012 ,1500 G. PER YHD. Was system pumped as part of the inspection? ❑ Yes /4 No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments fre, t 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 4. Type of System: Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system(yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract (to be obtained from system owner) and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank.Attach a copy of the DEP approval. ❑ Other(describe): Approximate age of all components, date installed (if known) and source of information: INSTALLED 8/11/2005. AGE 15 YEARS OLD. PER YARMOUTH HEALTH DEPT. Were sewage odors detected when arriving at the site? ❑ Yes /1 No 5. Building Sewer(locate on site plan): —4' Depth below grade: feet Material of construction: ❑ cast iron ® 40 PVC ❑ other(explain): >10 Distance from private water supply well or suction line: feet Comments (on condition of joints, venting, evidence of leakage, etc.): NO EVIDENCE OF LEAKAGE. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 9 of 18 Commonwealth of Massachusetts a ' F Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ` 1 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is required for every Auburndale MA 02466 3/16/2020 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 6. Septic Tank(locate on site plan): 3.5 Depth below grade: feet Material of construction: ►� concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No 10'X6'X5' 1500 G Dimensions: 4" Sludge depth: Distance from top of sludge to bottom of outlet tee or baffle 26" 0" Scum thickness 6" Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle 19" How were dimensions determined? CORETAKER Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): LIQUID LEVEL 48"AT OUTLET INVERT. NO EVIDENCE OF LEAKAGE. HAS PVC INLET TEE, PVC OUTLET TEE WITH 19" LEG AND GAS BAFFLE. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 18 , Commonwealth of Massachusetts _-' Title 5 Official Inspection Form f Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 7. Grease Trap (locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑ fiberglass • •olyethylene ❑ other(explain): Dimensions: PSf Scum thickness Distance from top of scum to top of outlet -- or baffle Distance from bottom of scum to bot - of outlet tee or baffle Date of last pumping: Date Comments (on pumping rec' mendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to , tlet invert, evidence of leakage, etc.): 8. Tight or Holding Tank (tank must be pumped at time of insp= `ion) (locate on site plan): Depth below grade: k e NO TIGHT TANK Material of construction: ❑ concrete ❑ metal ■ iberglass ❑ polyethylene ❑ other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 18 r • cam, Commonwealth of Massachusetts ; ' i Title 5 Official Inspection Form 1 =1= -- Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ° � ii- =% 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 8. Tight or Holding Tank (cont.) Alarm present: ❑ Yes ❑ No Alarm level: Alarm in wArking or• -r. ❑ Yes ❑ No Date of last pumping: Date Comments (condition of alarm and float switches, etc.): *Attach copy of current pumping contract (required). Is copy attached? ❑ Yes ❑ No 9. Distribution Box(if present must be opened) (locate on site plan): Depth of liquid level above outlet invert AT INVERTS Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): DBOX IS IN GOOD CONDITION WITH ONE PIPE IN AND 2 PIPES OUT. NO EVIDENCE OF SOLIDS CARRYOVER. FLOW DISTRIBUTION IS EVEN. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form 1 �= Subsurface Sewage Disposal System Form -Not for Voluntary Assessments .654) 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 10. Pump Chamber(locate on site plan): Pumps in working order: ® -s ❑ No* Alarms in working order: ■ Yes ❑ No* Comments (note condition of pump chamber, condition of pum - and appurtenances, etc.): ftte * If pumps or alarms are not in wor ng order, system is a conditional pass. 11. Soil Absorption System (S -) (locate on site plan, excavation not required): If SAS not located, exp - n why: Type: ❑ leaching pits number: .4 leaching chambers number: STOONENE W S ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 18 Commonwealth of Massachusetts ot--- -"ti Title 5 Official Inspection Form sSubsurface Sewage Disposal System Form -Not for Voluntary Assessments 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 11. Soil Absorption System (SAS) (cont.) Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): CHECKED SOIL AND STONE THROUGH OBSERVATION PORT, FOUND SOIL TO BE DRY AND STONE IS CLEAN. CHAMBER IS DRY AND NO SIGNS OF HYDRAULIC FAILURE. 12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow ❑ Yes ❑ No Comments (note condition of soil •ns of hydraulic failure, level of ponding, condition of vegetation, etc.): • t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 18 Commonwealth of Massachusetts 'F Title 5 Official Inspection Form fSubsurface Sewage Disposal System Form -Not for Voluntary Assessments ett � j'/ 19 Bradford Road,West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 13. Privy (locate on site plan): Materials of construction: Dimensions Depth of solids /.:k.( Comments (note condition of soil, signs of hydraulic . ure, level of ponding, condition of vegetation, etc.): t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 18 • • Commonwealth of Massachusetts fl Title 5 Official Inspection Form c -= Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 19 Bradford Road,West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/12/2020 required for every page. City/Town State Zip Code Date of inspection D. System Information (cont.) 14. Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building.Check one of the boxes below: ® hand-sketch in the area below ❑ drawing attached separately I 1w t R vhR 2e10 0i • • • - • lam.. mom temo mow '. _ 0.14 SWSt ether Al 8 3/' $/ =/6.S, pZ z 211° 52 = 2 2.5., 3 3/' 8 3 s 330.5- y,39.S. gy=233' tSinsp.doc•rev.7/28/2018 Title 5'Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 18 cam. Commonwealth of Massachusetts =,'_F Title 5 Official Inspection Form =_11_- Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 19 Bradford Road,West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 15. Site Exam: ® Check Slope ►� Surface water 15 Check cellar ® Shallow wells Estimated depth to high ground water: X7'8 feet Please indicate all methods used to determine the high ground water elevation: Obtained from system design plans on record If checked, date of design plan reviewed: 8/3/2005 Date ❑ Observed site (abutting property/observation hole within 150 feet of SAS) O Checked with local Board of Health -explain: El Checked with local excavators, installers- (attach documentation) El Accessed USGS database-explain: You must describe how you established the high ground water elevation: DESIGN TEST HOLE TO 10' NO GROUNDWATER ENCOUNTERED. 10/14/2004. GRADE TO SAS BOTTOM = 6.3' MIW29A ADJUSTMENT 10/2004=2.2' SEPARATION MATH 10- (6.3+2.2)= 1.5 Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 18 1 • • Commonwealth of Massachusetts } _ = Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 19 Bradford Road, West Yarmouth, MA Property Address Voskanian Shaunt 73 Williston Road Owner Owner's Name information is Auburndale MA 02466 3/16/2020 required for every page. City/Town State Zip Code Date of Inspection E. Report Completeness Checklist Complete all applicable sections of this form inclusive of: ® A. Inspector Information: Complete all fields in this section. ® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked ® C. Inspection Summary: 1, 2, 3, or 5 completed as appropriate 4 (Failure Criteria) and 6(Checklist)completed ® D. System Information: For 8: Tight/Holding Tank—Pumping contract attached For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 18 of 18