Loading...
HomeMy WebLinkAboutEngineer Plan - 2020O L v - LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- 98 -- EXISTING CONTOUR LOT 3 2�3 + 96.52 EXISTING SPOT GRADE AREA = 0.55 Ac. 82i W— EXISTING WATER SERVICE 5 ® TEST PIT 5 G c;,4 SCALE: 1"=20' 56 Gl.S \� 'Q PROP 1,500G SEP fIC TANK Al 0 9.8 �'----- \ o o� O 005 2. EXIST; 1 OOOG / h• / / 5 ti / SEPTIr TANK / 59a4 5 G- 50.7 i W / / J Permit valid for [IFTAW OF SEPTIC SVS'1 EIYI ONLY, dire to -State and Local seffic variances: Board of.11ealth review and approval is re4luired for any future additions/rend% rtions/aherations to sewage hu•ilitieS and/o'r structures/dwelling. 11armo�[?{u``th :Heappllli 1)epartment Ll' 3 2 0 2 YARMOUTHPORT Al HILLCREST RD. 9�� OG 0 -9j, OR �o k s 0-F LOCUS MAP LOCUS INFORMATION PLAN REF: 203/111 TITLE REF: 2328/088 PARCEL ID: MAP 151 PAR. 061 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 32 HILLCREST ROAD YARMOUTHPORT, MA PREPARED FOR WILILAM ARSENAUX/ READY ROOTER EXC. e APRIL 3, 2020 N OF MASS' OF VSs 0 STEVEN W m -A RUMBA N o DARREN,\ M i 1 sb,� SEG/5fEv 49.8 Name;, mate54 NITAR�p� 52 MEYER & SONS, INC. 4G.7 TBM = E► .47.0 API? 1 G 2020 P.O. BOX 981 TOP OF REBAR EAST SANDWICH, MA. 02537 ® i HEALTH DEPT, PH: (508)360-3311 FAX: (774)413-9468 SURVEY CONDUCTED BY: meyerandsonstitle5@gmail.com WELLER AND ASSOCIATES SHEET 1 OF 2 J#1894 NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE FINISHED GRADE (55.0-53.0) 61.50 F.G.ELc 58.0 F.G. EL: 55.5 ---\ -- SLAB EL \ MAINTAIN 2% MIN SLOPE OVER LEACHING AREA (Existing) = 60.0 :v ;, .. place sanitary tee 2" OF 3/8" DOUBLE WASHED Y F.G.EL» 57.25 �. ; 3/4' - 1-1/2' V.• - : • in d -box. •• STONE OR FILTER FABRIC 6' DOUBLE WASHED STONE ' '" 4" SCH 40 PVC 4. 10"1®®®®• O ®®®® e MIN.) ®®®®®®®®®®® 4E'S SCHARE 40 PVC2® ®®®®®® ® E 14 S 1% INV.52.50 ' EFF. DEPTH ®®® r INV: 56.0 -T INV. 52.30 41/2 X 8.5' 4' EXISTING ouTLEr BAF LE PROPOSED DB -3 INV. 58.0 DISTRIBUTION BOX EFFECTIVE LENGTH = 25' INV. 56.25 (H20) INV. ELEV.= 51.0 PROP. 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON ���`� OF 'ss9 BREAKOUT OUTLET TEE AS MANUFACTURED BY oDARREN M. s / ELEV.= 51.0 TUF-TITE, ZABEL, OR EQUAL ETOP CONC. ELEV.= 52.0 , No. i1/4C INV. ELEV.= 51.0 ®® 0 ®® NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING®®®®®® PIPE INVERTS PRIOR TO CONSTRUCTION MPEG/g[ ®®®®®®® 2) TANK/D-BOX SHALL BE SET LEVEL AND TRUE TO BOTTOM EL.= 49.0®®®la0IERLa GRADE ON A MECHANICALLY COMPACTED SIX 3.75 5 FT. 3.75' INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) SEPARATION 5.80 FT. EFFECTIVE WIDTH = 12.5' 3) INSTALL INLET & OUTLET TEES W/ SEPTIC SYSTEM PROFILE GAS BAFFLE AS REQUIRED SOIL ABSORPTION SYSTEM (SECTION) BOTTOM OF TESTHOLE EL: 43.20 � �� (500 GALLON LEACH CHAMBER) GENERAL NOTES: DESIGN CRITERIA I. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL SOIL LOGS BOARD OF HEALTH AND THE DESIGN ENGINEER. - NUMBER OF BEDROOMS: 3 BEDROOM DESIGN 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS DATE:.; MARCH 31, 2020 OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE � � SOIL EVALUATOR: DARREN MEYER R.S. CSE #1614 SOIL TEXTURAL CLASS: CLASS I (0.74 GPD/SF) LOCAL RULES AND REGULATIONS. DESIGN PERCOLATION RATE: <2 MIN/IN 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR WITNESS MALLORY LANGLER, YARMOUTH HEALTH DEPT. DAILY Flow: 110 G.P.D. X 3 BR = DESIGN FLOW: 330 G.P.D. TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. GARBAGE GRINDER: NO (not designed for garbage grinder) 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING Elev. TP- Depth 'FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGNSEPTIC TANK: 330 gpd x 200% = 660 gpd USE PROP. 1,5000 SEPTIC TANK ENGINEER BEFORE CONSTRUCTION CONTINUES. 54.20 ALOAMY SAND 0 5.. ALL ELEVATIONS BASED ON ASSUMED DATUM. 53.45 1OYR 3/1 9" LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. 6. THE DESIGN ENGINEER IS'NOT RESPONSIBLE FOR THE FAILURE OF g THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF LOAMY SAND USE TWO (2) 500 GALLON PRECAST LEACH CHAMBERS W/ 4, HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 51.02 10YR 5/6 38' STONE ON ENDS & 3.75' STONE ON SIDES: 25' L x 12.5' W x 2'D 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE _ C 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED BOTTOM AREA 25 x 12.5 = 312.5 SF TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. ;_ 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE MEDIUM SIDE AREA: (25 + 12.5) X 2 X 2 ' = 150 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING SAND CONSTRUCTION. P� TEST TOTAL SQUARE FEET PROVIDED = 462 vs. 45.94 REQ'D 2.5Y 6/4 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5. o EL. 49.40 DESIGN FLOW PROVIDED: 0.74(462 S.F = 342.25 G. D. vs. 330 G.P.D. req'd 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 43.20 1 132" PROPOSED SEPTIC ` S TEM UPGRADE P LAN 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. PERC RATE <2 MIN/IN. (-Cl- HORIZON) 32 HILLCREST ROAD, YARMOUTHPORT, MA 15. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPECIFIED) NO GROUNDWATER OBSERVED Prepared for: William Arsena x/Ready Rooter Exc. Design and Site Plan by: SCALE DRAWN DATE * 1, Darren M. Meyer, R.S., CSE, hereby certify that 1 am currently approved by MADEP pursuant to 310 CMR 15.017 MEYER& SONS, INC. N.T.S. DMM 04/03/20 to conduct soil evaluations and that the above anarysis has been performed by me consistent with the POBOX961 REV DATE requirements of 310 CMR 15.017. 1 further certify that 1 have passed the Soil Evol. Exam in October, 1999. E4STSANDW/CH,M402537 CHECKED SHEET NO. 506,962-2922 DMM 2 of 2