HomeMy WebLinkAboutEngineer Plan - 2003z d a U INSTALL 40 MIL. a POLY VAPOR BARRIER ALONG SECTION WITHIN 15 OF SLAB AND WALLcp' LOT 3 .11 o O. TP LOT 10 0 moo' OBSERVATION AND j - - - PUMPOUT PORT R,Is m W �x j -............ L 2 457± S. F11 � 4�B yfQ /, 'V Lq �o NOTES: LOTS 1 AND 2 ARE IN THE A-12,ELEV, 12 FLOOD ZONE. L/ k LOTS 1 AND 2 ARE IN THE `0, "R-25" ZONING DISTRICT. THE CLOSEST RESOURCE AREAvl OF ml IS GREATER THAN 200' AWAY. o.,, "1§Y g LAME NO. Sg LA%� LOT 11 p0, LOT I Q 8,485± S.F. 6' 0, Vis, � 8 ....................................... 0�' LANDSCAPING LIGHT IR, bq-�� , }9• AND VIEW EASEMENT INFAVOR FAVOR OF 'LOT 11 h'=20.00 ` `. `CORNER AS SHOWN4� ON 1952 TOWN L.O. 9.1 IT LEWIS BAY BOULEVARD LOCUS LEWIS BA Y SQUAD. MAP = HYANNIS and DENNIS AUG 1 8 2003 HEALTH DEPT. tN Of JOHN yG LANDERS-CAULEY `' Cl"L y No. 35101 aTERNG`��`�� aL E SITE PLAN PREPARED FOR DARLENE M. RICHARD, Tr. OF LOTS 1 & 2 YARMOUTH, MA J.E. LANDERS—CAULEY, P.E. CIVIL ENVIRONMENTAL ENGINEERING P.O. BOX 364 WEST FALMOUTH, MA 02574 (508) 540-7733 ph. (508) 540-3022 ph. 508 540 - 3344 fax ASS. # I DATE: 08118103 SCALE: 1" = 20' IDRAWN BY: JDR JOB NO. 848-03 SHEET: 1 OF 2 F. F. ELEV. =12, 50 ELEV.= 10.9_ 4" CAST IRON OR SCHEDULE 40 P.V,C. BRING ONE COVER TO WITHIN 6" OF FINISH GRADE DIST: = L3_2'_ SLP. = 0.02_ ELEV. = 9• �0_ ELEV.= 8_74 BRING COVER TO WITHIN 12" OF FINISH GRADE 'min. CONCRETE COVERS 4" CAST IRON SCHEDULE 40 P. V. C. SLP. = 0.005 INVERT CONCRETE COVER DIST. FLOW LINE DIST. = 2. F' _ SLP. = 0.02_ INVERT lo" MIN. 19^ ELEV. ELEV. = 8_49 8.43 GAS BAFFLE ELEV. _ __-" ELEV.= 8_26 4" CAST vc. DISTRIBUTION BOX 1500 GALLON SEPTIC TANK TO BE PLACED ON 6" OF STONE OR MECHANICALLY COMPACTED SOIL. USE A TANK WITH THREE COVERS. PROFILE OF SEWAGE DISPOSAL SYSTEM NOT TO SCALE GENERAL NOTES: 1. THIS PLAN IS FOR THE CONSTRUCTION OF A NEW SEWAGE DISPOSAL SYSTEM 2. PLAN REFERENCE LC 11435 A LOT 1 & 2 BARNSTABLE REG. OF DEEDS. 3. THIS PLAN IS FOR THE INSTALLATION /REPAIR OF SEPTIC SYSTEM AND NOT TO BE USED FOR SURVEYING AND ZONING PURPOSES. .t 4, ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 .AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 5. ' ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 12" OF THE FINISHED GRADE, 6. EXISTING AND FINAL GRADES SHALL REMAIN ESSENTIALLY THE SAME, UNLESS NOTED BY FINAL CONTOURS. 7. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10' OF DRIVES OR PARKING AREAS UNLESS NOTED. 8. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 9. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 10, THE EXCAVATOR/CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATION. OBSERVATION AND BRI,NGUCOVOER TO WITHIN 6 OF FINISH GRADE ELEV,= 10.9_ 4" DIA. SCHEDULE 40 PERFORATED PLASTIC PIPE I END CAPS ON ALL PIPES 5' ON CENTER A 3JEN OF 12"min v .WTONEo"o o"o" "o"o 0 0"0"0 0"0 0 0 0 0"0"0"0 0 0 0 0"0"00"0"0 "o 0o 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 00_0_0_0 0_0_0_0_0_0_0_0_ O_O_O_O_O_0_O_O_O_O_0_O_O_ _O_O_OO_ __0_(U 0 < 6" LAYER OF 0 /4" TO 1-1/2' O v v v v U U U U U U U (� O O U U U C` WASHED STONE O O O O O O O O O O O O O O O O O0�0�0� opo o„o„ _ � ELEV.=7_54 6» USE STONE STRIPOUT ALL UNSUITABLE A " TO BE WET TESTED IF TO LEVEL THE MATERIAL INSIDE AND 00000 6OF MORE THAN ONE OUTLET. WITHIN 5' OF THE SIDES o 0 o STONE 5.0 BED AS NEEDED. OF THE S.A.S. AND REPLACE TO BE PLACED ON- WITH MATERIAL THAT COMPLIES L 6" OF STONE OR ---------------- ---- WITH -TITLE 5 -STANDARDS ------------------------- MECHANICALLY COMPACTED SOIL. BOTTOM of TEST HOLE OR USGS PROBABLE WATER TABLE ELEV =2__5- ADJUSTED SOIL TEST DONE BY: J,E. LANDERS-CAULEY P.E. OBSERVATION AND BY 1.4' WITNESSED BY: AMY VAN HONE 08115103 LKELDA WELSH 8/15/03) PERCOLATION RATE: __2___MIN/INCH P# NONE TEST HOLE 1 DATE:(O /10L99)_ 08/15/03ELEV.-8.5____ DEPTH HORIZON TEXTURE COLOR MOTT. OTHER 0"-5" 0/A 5"-11" E ',OAMY SAND 10YR 5/3 11"-22" B LOAMY SAND 10YR 5/8 22"-62" C1 MED. SAND 10YR 6/4 62"-75" C2 MED. SAND 7.5Y 4/4 75"-120" C3 MED. SAND 10YR 6/4 H2H2 O AT TFCT POT P 9 DATE- (08/10/99) 08/15/03 ELEV. 8.5 __ DEPTH HORIZON TEXTURE COLOR MOTT. OTHER 0"-4" 0/A 4"-13" E LOAMY SAND 10YR 5/3 13"-29" B LOAMY SAND IOYR 5/8 29"-60" C1 MED. SAND 10YR 6/4 60"-68" C2 MED, SAND 7.5Y 4/4 H2O AT 68"-120" C3 MED. SAND 10YR 6/4 89" BRI'N OF 'o�o�o�o�o�o o� "oyo�oyo�wASHEdSTONE �40) "v ���� 6"�AYEROF C) 3/4 p 1-1/2" WASH D STONE 3 PERFORATED PIPES SECTION A -A I HEREBY ATTEST THAT I AM A CERTIFIED SOIL EVALUATOR IN THE C MMO WEALTH OF MASSACHUSETTS, A ' T A I WAS PRESENT FOR THE SOI S AND EVALUATION. ---� - --------------- 1), ------- 15 T '' NAME DESIGN DATA: NUMBER OF BEDROOMS FQUR_(4)____ GARBAGE DISPOSAL-NO_NE_(9)-_-__— TOTAL ESTIMATED FLOW 44Q ----- GPD GAL./BR./DAY X ,4____ BR. ) SEPTIC TANK CAPACITY J,QQQS9L.__ LEACHING AREA REQUIREMENTS SIDEWALL AREA 0_-__ GAL. /S. F. BOTTOM AREA _�Q2___ GAL./S.F. LEACHING CAP.(BOT. & SIDEWALL)_ 444 _ GAL. RESERVE LEACHING CAPACITY _444 ___ GAL. APPLICANT: DARLENE M. RICHARD, Tr. I DATE: 08/18/03