Loading...
HomeMy WebLinkAboutBldsm-20-004316 • Commonwealth of Massachusetts Sheet Metal Permit Date: / i //�j Permit#: Btd5/1/ (13l,6 Estimated job cost:/ •; 4 C Permit fee: Plans submitted:Yes Nq Plans reviewed: Yes No Business license: 922 6 Applicant License: `J 77 6 Business info ution goo '/®: minformation Name: /c7s c, Name: n30.- S Street: 12 G I Street: 'l ��Ae" 1) S ;a City/town: 1 C 7 .� G•-7irJ, • City/to �r l=� ���✓L �1�ir-. Telephoner 6 • ;3 c Telephone: \\ &3i\joi-+ek..94\fOr •( • Photo ID attached?(required): Yes ✓ No IN VAVN J-1/M-1 unrestricted license J 2/M-2 restricted to 3 stories or fewer and commercial up to 10,000 sq. ft./2 stories or fewer tJ Residential: 1-2 family ✓ Multifamily amily Condo/townhouse Other Commercial; Office Retail_ Industrial Educational Institutional Other • Square footage:Under 10,000 sq.ft. ;/Over 10,000 sq. ft._ Number of stories • Work to be completed:New work ..�/Renovation . HVAC ✓ Metal watershed roofing— Kitchen exhaust system_ Metal chimney/vents— Air balancing_ Detailed description of work,including g information from ACCA manuals S,J,and D. (If this information is excessively long,it can be emailed to L,�`• /74 /77 - <,, P/1 /F /cri, r Y,,� 0 < l 1 , �� /11C731D S • • - INSURANCE 90VERAOE: I have a current)lability,Insurance policy or its equivalent which meets the requi ernent.of M.O.L.Ch.112 Yes 0 No❑ . If you have checked In,indicate the of coverage by cheddng the appropriate box below . • A liability.Insurance policy Other type of indemnity 0 Bond ❑ OWNER'S INSURANCE WAIVER:I am aware that the license does not have the Insurance coverage required by Chapter 112 of the ' Maseach oral Laws,and that my signature on this permit application Blip this requirement. _ , Check One Only . L® . . ❑ Agent j] :7-----:—. signature of Owner or Owne•A ' . _ • By checking the boxD,I h"etstlfyl thatthitallefiltriadle imdhifortnation I have enbmit d(or entered) •; "'` .,-t ,41 ,• Ito trn.and accurate to the best of my knowledge and+tat sU,gheet metal work and Installation's performed under the penult ieeuod forthb application Will be In oomptirmce with all pertinent provision of the Maaaghusetts Bonding Code and Chapter 112 of the General Laws. . Duct inspection required prior to Insulation installation:YES NO Inspections • • • ' • • .,.,r,,...-+r.:— . • -, A,f..;: = ,-•^,�..y-+y�-.._ ,--,a4,,,._ ? -a'ayy-.... -t :� ' ',nu-,c-�.�b _ ,-,.,, -:=Eat:*+z'r�=..,`-' .;.i, ligi•.ti. • Fhtal Iuavecdon , �° ❑Master-Restricted "LS-----, • alOUmeyperson Pm** Signature of Licensee • Fee= u n-Re L e Number: '/ 76• Check atwww.mass.uovidig • �� /-6s. 'Id --- . ' km/peeler ggliature of Ps Approvsf • • . • • ....:... . .. ,3 . tizenAccess/Default.aspx ie,ericmeadsinc... ; I ASSESSORS DATAB,,, AHRI Certification.., YY FUJITSU el Bryant Registration Q Sid Harvey �11 Johnstone Supply -7 Homans Associates 0 F.W.Webb please contact the issuing Agency directly using the links below. Contact Ali iiholic Beverages Control Commission Contact i)r^patr Starzti.arris Contact tiiveoo n of r-ofiess,n l Licensure Translation information-Click Here To apply for an Energy and Environmental Affairs(DEP.MDAR or DCR)permit or license,please click here. Convenience Fee;For DPL and DLS transactions,please note that all on line credit card transactions incur a 2.35%convenience fee.There is a of$0.35 associated with online payment by ACH/EFT. For ABCC transactions,please note that all on line credit card transactions incur a 2.35%convenience fee Home Manage Licenses,Permits and Certificates File and Track Complaints File an Online Application Manage My Licenses,Permits it Certificates Record 4776-SM-Ml: Acid to collection Sheet Metal Master License Record Status:Current Expiration Date:01/28/2022 Record info o Payments' Education . Custom Component Premise Address Record Details Licensed Professional: ERIC V MEADS MI 52 Great Oak Rd Brewster,MA,02631-1732 United States Sheet Metal Master 4776 More Details Create Anwtnt • ��I t ta10S ..c cif co v s ,.1F rt -4®r� S V# IL t , 0 v N o a � t {� t1 N .�. o _ '� L o _ a eir- rn. Y •` x cl 3; Zz +a,® _ U m z w v: Betterwood Homes-harbor Rd HVAC Load Calculations for ElhEASdi R H''A HVIAC L Prepared By: Evm Meads Mechanical PO Box 1207 Brewster Ma.02631 508-896-8950 Wednesday, February 5,2020 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. .47 ... �.._> wsa .z'' ,...�� ,F-�.�..,. �_ .,.. �_ar>is -1_+i, 'A� z 2 Project Report General Project Information Project Title: Betterwood Homes-harbor Rd Designed By: Evm Project Date: 2-1-2017 Company Name: Meads Mechanical Company Representative: Evm Company Address: PO Box 1207 Company City: Brewster Ma. 02631 Company Phone: 508-896-8950 Company Comment: Design Data Reference City: East Falmouth, Massachusetts Building Orientation: Front door faces North Daily Temperature Range: Low Latitude: 42 Degrees Elevation: 131 ft. Altitude Factor: 0.995 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb ReLHum Re.I.Eurn Dry Bulb Difference Winter: 10 12.83 n/a n/a 70 n/a Summer: 88 72 47% 50% 72 34 Check Wires Total Building Supply CFM: 2,126 CFM Per Square ft.: 0.736 Square ft. of Room Area: 2,890 Square ft. Per Ton: 599 Volume(ft3)of Cond. Space: 22,928 Building Loads Total Heating Required Including Ventilation Air: 53,027 Btuh 53.027 MBH Total Sensible Gain: 46,543 Btuh 80 % Total Latent Gain: 11,369 Btuh 20 Total Cooling Required Including Ventilation Air: 57,911 Btuh 4.83 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM s " s a a ,, e'er „ !! a � r a s Load Preview Report Sys ,uct Scope Cig Act Ton /Tor Area Gain Gain Gai Loss S FM Size CFM CFM CFM Building 4.83 599 2,890 46,543 11,369 57,911 53,027 692 2,126 2,126 System 1 1.87 630 1,177 17,303 5,107 22,409 23,852 311 790 790 10x1; Duct Latent 416 416 Zone 1 -Clq.:37%.Htq.:48% 617 7,176 1,794 8,970 11,474 150 328 328 7x1C 1-Living Room 240 4,602 776 5,378 5,241 68 210 210 2--6 2-Bath 1 84 405 145 550 885 12 19 19 1--3 3-Bath 2 100 1,247 485 1,732 2,857 37 57 57 1-4 4-Laundry 50 180 121 301 690 9 8 8 1--2 8-Entry 143 742 267 1,009 1,801 23 34 34 1--3 Zone 2-Ciq.:63%.Htq.:52% 560 12,173 2,897 15,070 12,378 162 558 556 9x1 5-Bedroom 2 273 5,839 1,224 7,063 5,889 77 287 267 3--6 6-Bedroom3 143 3,854 982 4,836 4,097 53 178 176 2--5 7-Bedroom 4 144 2,480 691 3,171 2,393 31 113 113 2-4 System 2 2.01 567 1,140 20,999 3,143 24,142 18,044 235 089 959 11x16 Zone 1 -Cia.:72%.Hta.:69% 776 17,109 1,893 19,002 12,486 163 781 781 10x1° 9-Kittchen Dining 540 9,549 1,146 10,695 9,080 118 438 436 4-6 10-Greaty Room 168 6,496 608 7,104 2,443 32 297 297 3-6 11-Hall 32 892 139 1,031 963 13 41 41 1-4 12-Half Bath 36 171 0 171 0 0 8 8 1--2 Zone 2-Clq.:28%,Htq.:31% 364 6,712 1,250 7,962 5,558 73 307 307 7x9 13-Master Bedroom 204 4,335 903 5,238 3,605 47 198 198 2-6 14-Master Bath 100 2,035 347 2,382 1,953 25 93 93 1--6 15-Closet 60 342 0 342 0 0 18 16 1--2 System 3 0.95 605 573 8,241 3,119 11,36C 11,131 145 378 376 8x10 Zone 1 573 8,241 3,119 11,360 11,131 145 376 376 8x1C 16-Bedroom 5 192 4,395 1,725 6,120 6,147 80 201 201 2--6 17-Bath 1 81 726 426 1,152 1,765 23 33 33 1--3 18-Bedroom 6 132 2,554 968 3,522 2,833 37 117 117 2-4 19-Closet 96 340 0 340 261 3 18 16 1-2 20-Hall 72 227 0 227 125 2 10 10 1-2 Sum of room airflows may be greater than system airflow because system has multiple zones. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM • Iv.:11,,,,..,,, ,,l;:,,,:t_i,".14,t,..., ..,, , -:•,-:,,.,.,---,:- 3, -1.c•:•, ',:,.... -.,':==.• . -- : , - - -,---- r7.7.......„. ...„...,r:3,7„ � ,,t om'ate:t", . - - .- r., _.. *& . _' ..+.s'.�"t: �. i,?- ,€ s .,_.�.. .. ? a .._ ..,. ,.,-.�..._ A.. ..cap,::..,' ' --.._,,..., ., ,_... .,. _,. Duct Size Preview Room or Source Minimum Maximurr Rough Design SP Duct Duct c DuctAct. D Duct Name Velocitli Velocity Factor U10C Loss Velocity Lengtt Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Living Room Built-In 450 750 0 0.1 535.2 68 210 2--6 2-Bath 1 Built-In 450 750 0 0.1 377.1 12IIIIII 19 1--3 3-Bath 2 Built-In 450 750 0 0.1 652.6 37 57 1--4 4-Laundry Built-In 450 750 0 0.1 377.1 9 8 1--2 8-Entry Built-In 450 750 0 0.1 690.6 23 34 1-3 Zone 2 5-Bedroom 2 Built-In 450 750 0 0.1 452.7 77 267 3-6 6-Bedroom3 Built-In 450 750 0 0.1 645.5 53 176 2--5 7-Bedroom 4 Built-In 450 750 0 0.1 649.1 31 113 2-4 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0 0.1 758.6 311_I 790 10x1f. System 2 Supply Runouts Zone 1 9-Kittchen Dinina Built-In 450 750 0 0.1 555.3 118 436 4-6 10-Greaty Room Built-In 450 750 0 0.1 503.7 32 297 3--6 11-Hall Built-In 450 750 0 0.1 467 13 41 1-4 12-Half Bath Built-In 450 750 0 0.1 358.5 0 8 1-2 Zone 2 13-Master Bedroom Built-In 450 750 0 0.1 504.1 47 198 2--6 14-Master Bath Built-In 450 750 0 0.1 473.3 25 93 1-6 15-Closet Built-In 450 750 0 0.1 717 0 16 1--2 Other Ducts in System 2 Supply Main Trunk Built-In 650 900 0 0.1 784.7 235-I 959 11x16 System 3 Supply Runouts Zone 1 16-Bedroom 5 Built-In 450 750 0 0.1 511.1 80 201 2-6 17-Bath 1 Built-In 450 750 0 0.1 675 23 33 1-3 18-Bedroom 6 Built-In 450 750 0 0.1 668.3 37 117 2--4 19-Closet Built-In 450 750 0 0.1 710.7 3 16 1-2 20-Hall Built-In 450 750 0 0.1 474.2 21.1 10 1--2 Other Ducts in System 3 Supply Main Trunk Built-In 650 900 0 0.1 677.4 145 I 376 8x1C Summary System 1 Heating Flow: 311 Coolina Flow: 790 System 2 Heatina Flow: 235 Cooling Flow: 959 System 3 Heating Flow: 145 Coolina Flow: 376 C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM System 1 System 1 first Floor Summary Loads Component Area Son Let San Total Description Ouan Loss Gekt Gain Gehl 1D-cv-o: Glazing-Double pane, operable window, clear, 136 4,651 0 6,171 6,171 vinyl frame, ground reflectance=0.23, u-value 0.57, SHGC 0.56 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 1016 3,962 0 1,340 1,340 cavity, no board insulation, siding finish,wood studs 19A-21 p: Floor-Over enclosed unconditioned crawl 1177 2,535 0 676 676 space, No insulation on exposed walls, sealed or vented space, passive, R-21 blanket Subtotals for structure: 11,148 0 8,187 8,187 People: 6 1,200 1,380 2,580 Equipment: 0 0 0 Lighting: 1300 4,433 4,433 Ductwork: 2,594 416 552 968 Infiltration: Winter CFM: 154, Summer CFM: 151 10,110 3,491 2,644 6,135 Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0 Exhaust: Winter CFM: 150, Summer CFM: 150 AED Excursion: 0 0 106 106 System 1 System lfirst Floor Load Totals: 23,852 5,107 17,303 22,409 Check Figures Supply CFM: 790 CFM Per Square ft.: 0.671 Square ft. of Room Area: 1,177 Square ft. Per Ton: 630 Volume(ft3)of Cond. Space: 9,416 System Loads Total Heating Required Including Ventilation Air: 23,852 Btuh 23.852 MBH Total Sensible Gain: 17,303 Btuh 77 Total Latent Gain: 5,107 Btuh 23 % Total Cooling Required Including Ventilation Air: 22,409 Btuh 1.87 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM �.* ;" :' "kc`� yr s ,To-'Pzt�'a ,... 7m -. ...,�..,. r`�sir, - f System 2 Middle Floor System Summary Loads Component Area Sen Let Sen Toad Description Quart Loss Gain Gain Gain 1 D-cv-o: Glazing-Double pane, operable window, clear, 228 7,795 0 10,803 10,803 vinyl frame, ground reflectance=0.23, u-value 0.57, SHGC 0.56 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 852 3,323 0 1,123 1,123 cavity, no board insulation, siding finish,wood studs Subtotals for structure: 11,118 0 11,926 11,926 People: 4 800 920 1,720 Equipment: 0 1,500 1,500 Lighting: 1400 4,774 4,774 Ductwork: 0 0 0 0 Infiltration:Winter CFM: 105, Summer CFM: 101 6,926 2,343 1,776 4,119 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Exhaust: Winter CFM: 100, Summer CFM: 100 AED Excursion: 0 0 103 103 System 2 Middle Floor System Load Totals: 18,044 3,143 20,999 24,142 check Figures Supply CFM: 959 CFM Per Square ft.: 0.841 Square ft. of Room Area: 1,140 Square ft. Per Ton: 567 Volume(ft3)of Cond. Space: 9,120 System Loads Total Heating Required Including Ventilation Air: 18,044 Btuh 18.044 MBH Total Sensible Gain: 20,999 Btuh 87 % Total Latent Gain: 3,143 Btuh 13 % Total Cooling Required Including Ventilation Air: 24,142 Btuh 2.01 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM 4 � �, System 3 System 3 Top Floor Summary Loads Component Ama San Lat Sett Total Description tit Loss Gain Gain Gab" 1D-cv-o: Glazing-Double pane, operable window, clear, 52 1,781 0 1,735 1,735 vinyl frame, ground reflectance=0.23, u-value 0.57, SHGC 0.56 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 340 1,326 0 450 450 cavity, no board insulation, siding finish,wood studs 12F-0sw: Part-Frame, R-21 insulation in 2 x 6 stud cavity, 288 374 0 374 374 no board insulation, siding finish,wood studs 18A1-36o: Roof/Ceiling-Roof Joists Between Roof Deck 573 997 0 447 447 and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel, R-36 open cell 1/2 lb. spray foam, 9.5 inches in 2 x 10 joist cavity, 1 inch on joist Subtotals for structure: 4,478 0 3,006 3,006 People: 4 800 920 1,720 Equipment: 0 0 0 Lighting: 750 2,558 2,558 Ductwork: 0 0 0 0 Infiltration:Winter CFM: 101, Summer CFM: 100 6,653 2,319 1,757 4,076 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Exhaust: Winter CFM: 100, Summer CFM: 100 System 3 System 3 Top Floor Load Totals: 11,131 3,119 8,241 11,360 Check Figures Supply CFM: 376 CFM Per Square ft.: 0.657 Square ft. of Room Area: 573 Square ft. Per Ton: 605 Volume(ft3)of Cond. Space: 4,392 System Loads Total Heating Required Including Ventilation Air: 11,131 Btuh 11.131 MBH Total Sensible Gain: 8,241 Btuh 73 % Total Latent Gain: 3,119 Btuh 27 % Total Cooling Required Including Ventilation Air: 11,360 Btuh 0.95 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM System 1, Zone 1 Summary Loads (Peak Load Procedure for Rooms) Component Ann Sen La# San Total Description Quan Los* Gain Gain Goal 1D-cv-o: Glazing-Double pane, operable window, clear, 46 1,573 0 3,135 3,135 vinyl frame, ground reflectance=0.23, u-value 0.57, SHGC 0.56 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 546 2,129 0 720 720 cavity, no board insulation, siding finish,wood studs 19A-21 p: Floor-Over enclosed unconditioned crawl 617 1,329 0 354 354 space, No insulation on exposed walls, sealed or vented space, passive, R-21 blanket Subtotals for structure: 5,031 0 4,209 4,209 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 400 1,364 1,364 Ductwork: 1,248 0 205 205 Infiltration: Winter CFM: 79, Summer CFM: 78 5,195 1,794 1,359 3,153 System 1, Zone 1 Load Totals: 11,474 1,794 7,176 8,970 Check Figures Supply CFM: 328 CFM Per Square ft.: 0.531 Square ft. of Room Area: 617 Square ft. Per Ton: 825 Volume(ft3)of Cond. Space: 4,936 Zone Loads Total Heating Required: 11,474 Btuh 11.474 MBH Total Sensible Gain: 7,176 Btuh 80 Total Latent Gain: 1,794 Btuh 20 Total Cooling Required: 8,970 Btuh 0.75 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM System 1, Zone 2 Summary Loads Peak Load Procedure for Rooms) Component Area San Lat San Tote Description Quan Loss Gain Ofthl 1 D-cv-o: Glazing-Double pane, operable window, clear, 90 3,078 0 5,083 5,083 vinyl frame, ground reflectance=0.23, u-value 0.57, SHGC 0.56 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 470 1,833 0 620 620 cavity, no board insulation, siding finish,wood studs 19A-21p: Floor-Over enclosed unconditioned crawl 560 1,206 0 322 322 space, No insulation on exposed walls, sealed or vented space, passive, R-21 blanket Subtotals for structure: 6,117 0 6,025 6,025 People: 6 1,200 1,380 2,580 Equipment: 0 0 0 Lighting: 900 3,069 3,069 Ductwork: 1,346 0 348 348 Infiltration:Winter CFM: 75, Summer CFM: 73 4,915 1,697 1,285 2,982 System 1, Zone 2 Load Totals: 12,378 2,897 12,173 15,070 Check Figures Supply CFM: 556 CFM Per Square ft.: 0.993 Square ft. of Room Area: 560 Square ft. Per Ton: 446 Volume(ft3)of Cond. Space: 4,480 Zone Loads Total Heating Required: 12,378 Btuh 12.378 MBH Total Sensible Gain: 12,173 Btuh 81 Total Latent Gain: 2,897 Btuh 19 % Total Cooling Required: 15,070 Btuh 1.26 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM �. u ����°,�� _ t «'fix � .d�,��* +f� '. <. _..,.4 .� ?'�,`.� �,.,-,.. �.�� ,. System 2, Zone 1 Summary Loads (Peak Load Procedure for Rooms) Component Area Sen Let San To Dena iption Ousel Loss Gad Gail Gehl 1 D-cv-o: Glazing-Double pane, operable window, clear, 178 6,085 0 10,885 10,885 vinyl frame, ground reflectance =0.23, u-value 0.57, SHGC 0.56 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 510 1,989 0 672 672 cavity, no board insulation, siding finish,wood studs Subtotals for structure: 8,074 0 11,557 11,557 People: 2 400 460 860 Equipment: 0 1,500 1,500 Lighting: 700 2,387 2,387 Ductwork: 0 0 0 0 Infiltration:Winter CFM: 67, Summer CFM: 65 4,412 1,493 1,131 2,624 System 2,Zone 1 Load Totals: 12,486 1,893 17,109 19,002 Check Supply CFM: 781 CFM Per Square ft.: 1.007 Square ft. of Room Area: 776 Square ft. Per Ton: 490 Volume(ft3)of Cond. Space: 6,208 Zone Loads Total Heating Required: 12,486 Btuh 12.486 MBH Total Sensible Gain: 17,109 Btuh 90 % Total Latent Gain: 1,893 Btuh 10 % Total Cooling Required: 19,002 Btuh 1.58 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM System 2, Zone 2 Summary Loads (Peak Load Procedure for Rooms) Component Area Sen Lat Son Tick Description alert Loss Gal Gsih C 1 D-cv-o: Glazing-Double pane, operable window, clear, 50 1,710 0 2,740 2,740 vinyl frame, ground reflectance=0.23, u-value 0.57, SHGC 0.56 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 342 1,334 0 451 451 cavity, no board insulation, siding finish,wood studs Subtotals for structure: 3,044 0 3,191 3,191 People: 2 400 460 860 Equipment: 0 0 0 Lighting: 700 2,387 2,387 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 38, Summer CFM: 37 2,514 850 645 1,495 System 2, Zone 2 Load Totals: 5,558 1,250 6,712 7,962 Check Figures Supply CFM: 307 CFM Per Square ft.: 0.842 Square ft. of Room Area: 364 Square ft. Per Ton: 549 Volume(ft3)of Cond. Space: 2,912 Zone Loads Total Heating Required: 5,558 Btuh 5.558 MBH Total Sensible Gain: 6,712 Btuh 84 cio Total Latent Gain: 1,250 Btuh 16 Total Cooling Required: 7,962 Btuh 0.66 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM Y "°. �^'. ` ; - # i srt 5._ .r a , System 3, Zone 1 Summary Loads (Average Load Procedure for Rooms) Component Area San Lat Set Total Description Quam Loss Can Gain C 1 D-cv-o: Glazing-Double pane, operable window, clear, 52 1,781 0 1,735 1,735 vinyl frame, ground reflectance =0.23, u-value 0.57, SHGC 0.56 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 340 1,326 0 450 450 cavity, no board insulation, siding finish,wood studs 12F-0sw: Part-Frame, R-21 insulation in 2 x 6 stud cavity, 288 374 0 374 374 no board insulation, siding finish,wood studs 18A1-36o: Roof/Ceiling-Roof Joists Between Roof Deck 573 997 0 447 447 and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel, R-36 open cell 1/2 lb. spray foam, 9.5 inches in 2 x 10 joist cavity, 1 inch on joist Subtotals for structure: 4,478 0 3,006 3,006 People: 4 800 920 1,720 Equipment: 0 0 0 Lighting: 750 2,558 2,558 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 101, Summer CFM: 100 6,653 2,319 1,757 4,076 System 3,Zone 1 Load Totals: 11,131 3,119 8,241 11,360 Check Figures Supply CFM: 376 CFM Per Square ft.: 0.657 Square ft. of Room Area: 573 Square ft. Per Ton: 605 Volume(ft3)of Cond. Space: 4,392 Zone Loads Total Heating Required: 11,131 Btuh 11.131 MBH Total Sensible Gain: 8,241 Btuh 73 Total Latent Gain: 3,119 Btuh 27 % Total Cooling Required: 11,360 Btuh 0.95 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\betterwood harbor dr.rh9 Wednesday, February 5, 2020, 7:12 AM Accela Citizen Access Page 1 of 2 Announcements Register for an Account Login Need Help?For technical assistance in using this web application,please call the Search... ePLACE Help Desk Team at(844)733-7522 .�z or(844)73-ePLAC between the _._. hours of 7:30 AM-5:00 PM Monday-Friday,with the exception of all Commonwealth and Federally observed holidays.If you prefer,you can also e-mail us at ePLACE_helpdesk@state.ma.us.For assistance with non- technical issues,please contact the issuing Agency directly using the links below. Contact Alcoholic Beverages Control Commission Contact Department of Labor Standards Contact Division of Professional Licensure To apply for an Energy and Environmental Affairs(DEP,MDAR or DCR)permit or license,please click here. Convenience Fee: For DPL and DLS transactions,please note that all on line credit card transactions incur a 2.35%convenience fee.There is a fee of$0.35 associated with online payment by ACH/EFT. For ABCC transactions,please note that all online credit card transactions incur a 2.35%convenience fee Home Manage Licenses,Permits and Certificates File and Track Complaints Advanced Search Please refer to the Licensing Entity's website for additional information regarding the status and discipline information shown below. For DPL information,please visit the DPL website. For ABCC information,please visit the ABCC website. Information Pertaining To: Sheet Metal Master 4776 Licensee Detail License Number: 4776 Licensing Entity: Board of Examiners of Sheet Metal Workers License Type: Sheet Metal Master Type Class: M1 License Issue Date: 12/03/2010 License Expiration Date: 01/28/2022 Status: Current Current Discipline: Prior Discipline: Name: ERIC V MEADS Business Name: DBA Name: Public Documents https://elicensing.mass.gov/CitizenAccess/GeneralProperty/LicenseeDetail.aspx?LicenseeN... 2/6/2020