HomeMy WebLinkAboutBld-20-003597 I
a
ONE & TWO FAMILY ONLY-BUILDING PERMIT
Town of Yarmouth Building Department
1146 Route 28,South Yarmouth,MA 02664-4492 �' '�
508-398-2231 ext. 1261 Fax 508-398-0836 il,; tl
Massachusetts State Building Code,780 CMR
Building Permit Application To Construct,Repair, Renovate Or Demolish
a One-or Two-Family Dwelling
This Section For Official Use Only
Building Permit NumbergtD.",21) L-or) f� Date Applied: t J 2 t 12-otei
I itm Deft is
Building Official(PrintName) Si re Date
310 l D , 01.,;vk SECTION 1:SITE INFORMATION .
. 1.1 Property Ad),‘
d $,� �dress: 1.2 AssessorsCp&Parcel Number
1.1 a Is this an accepted street?yes V no Map Number Parcel Number
1.3 Zoning Information: 1.4 Property Dimensions:
Zoning District Proposed Use Lot Area(sq ft) Frontage(ft)
1.5 Building Setbacks(ft)
Front Yard Side Yards Rear Yard
Required Provided Required Provided Required Provided
1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System:
Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal Cl On site disposal system 0
Check if yes❑
SECTION Z: PROPERTY OWNERSHIPI
2.1 Owner'of Record:
LyntNDA• Z NAcfa 310 L.okrti Valvn N:
Name(Print) J City,State,ZIP 1
So�s1,. YAP.rnou.t 1^ +MA 02 664 5°e 32$' 14%01 IywNAsiquAc;o P t.o„c.ocikec
No.and Street Telephone JEmail Address
' SECTION.3:DESCRIPTIQN OF PROPOSED WORK2(check all that apply)
New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0
Demolition 0 Accessory Bldg.0 Number of Units Other. Specify:5c1Ag PA'e Ls
Brief Description of Proposed Work2:
i PsrAkk koof- 1 Aw`_av
rnt lb atkeec A So\re. pko-ro >1A-A it. .r 4afr-A
Gv A state* .�i"5t[ ikaoF ty5?te. I
A
SECTION 4 ESTIMATED CONSTRUCTION COSTS -; j.'
Estimated Costs: -.
Item Official Use Only
(Labor and Materials) :
1.Building $ 4i 0U ,u :1.'Building Permit'Fee:$..
5 ;
C) Indicate how feeis determine&
2.Electrical $ 0,$) 0 Standard CiTyITown Application.Fee: ': :
17 Q0O'
t 0 Total Project Costa(Item 6)x multiplier x
3.Plumbing $ 2: Otheriees: $ 1 - -
-t:
4.Mechanical (HVAC) $ List . .
5.Mechanical (Fire ..,. . ..
$ _
Suppression) Total All Fees:$. : .
Checkl46. Check Amount Cash Amount:
6.Total Project Cost: $ 211 TO-C' "G 6 paid inFu l ❑Outstanding Balance Due: 430
• SECTION 5:.CONSTRUCTION SERVICES
• 5.1 Construction Supervisor License(CSL)
+coke 114 t z.i t.,2C, License Number Expiration Date
Name of C L Holder
List CSL Type(see below)
£ UuR‘s tti
No,and Street �'}�C Description
W Unrestricted(Buildings up to 35,000 cu.ft.)
1M A t't V''L R Restricted 1&2 Family Dwelling_
City/Town,State,ZIP M Masonry
RC Roofing Covering
WS Window and Siding
SF Solid Fuel Burning Appliances
S``{`1l, 1,��( *CO •vj.,ccwt.;,, 4.cIes,,,►S I Insulation
Telephone Email address D Demolition
5.2 Registered Home Improvement Contractor(HIC) ct
GCAP, .<;.3 HIC Registration Number Expiration Date
HIC Company Name or HIC Registrant Name ,,/2 ID:,�, S A� 5iM ut4.te.+...L..vet et...s
No.and Street ' Email address
esrF�s=v Woe- 000St.. CI9 tCHt>1 ;i
City/Town,State,ZIP Telephone
SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide
this affidavit will result in the denial of the Issuance of the building permit.
Signed Affidavit Attached? Yes No ❑
SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN
• • OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT ..
I,as Owner of the subject property,hereby authorize 4-,p L e L e. .,c zit /(,;a sl eeti
to acton my behalf,in all matters relative to work authorized by this building permit application.
L y wy 14 IyP*A C.i c: l2 7 1 t`36
Print'Owner's Name(Electronic Signature) Dat
SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION
By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information
contained in this application is true and accurate to the best of my knowledge and understanding.
S-VrAhtN wt .zre LZ w z,Aq
Print Owner's or Authorized Agent's Name(Electronic Signature) • Date
NOTES:
1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor
(not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration
program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at
www.mass.gov/oca Information on the Construction Supervisor License can be found at www.znass.aov/dps
2. When substantial work is planned,provide the information below:
Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch)
Gross living area(sq.ft.) , Habitable room count
Number of fireplaces Number of bedrooms
Number of bathrooms Number of half/baths
Type of heating system Number of decks/porches
Type of cooling system Enclosed Open
•
3. "Total Project Square Footage"may be substituted for"Total Project Cost"
` The Commonwealth of Massachusetts Print Form
i Department of Industrial Accidents
1,,‘-== ' ' Office of Investigations
I_ _ . --4
/ 1 Congress Street, Suite 100
`, Boston,MA 02114-2017
may`%�'
,ti �' www.mass.gov/dia
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information Please Print Legibly
Name (Business/Organization/lndividual):Go Green Industries Inc.
Address: 2 Doris Road
City/State/Zip:Westford MA 01886 Phone #:978-496-1881
Are you an employer? Check the appropriate box: Type of project(required):
1. ✓❑ I am a employer with 3 4. ❑ I am a general contractor and I
employees(full and/or part-time).* have hired the sub-contractors 6. ❑New construction
listed on the attached sheet. 7. ❑ Remodeling
2.El I am a sole proprietor or partner-
ship and have no employees These sub-contractors have 8. ❑ Demolition
working for me in any capacity. employees and have workers' 9. ❑ Building addition
[No workers' comp.insurance comp. insurance.:
required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions
officers have exercised their MD Plumbing repairs or additions
3.❑ I am a homeowner doing all work
myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs
insurance required.] t c. 152, §1(4),and we have no Solar
employees. [No workers' 13.0 Other
comp. insurance required.]
*Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
:Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name:The Hartford Group
Policy#or Self-ins.Lic. #: 6S60UB2E90452119 Expiration Date:7/17/2020
Job Site Address:310 Long Pond Drive City/State/Zip:S Yarmouth, MA 02664
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DI' for insurance coverage verification.
I do hereb certifyr the , ,ins d penalties of perjury that the information provided above is true and correct
Signature: i A , -Ak _ Date
J12/20/2019
Phone#:978-496-1881
Official use only. Do not write in this area,to be completed by city or town official
City or Town: Permit/License#
Issuing Authority(circle one):
1.Board of Health 2.Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector
6. Other
Contact Person: Phone#:
• 3ti. s - oII Y ,� TOWN OF YARMOUTH
. o ; :yl. c B UIIJD ING DEPARTMENT
MENT
�1 -..• . ,r 1146 Route 28,South Yarmouth,MA 02664
*- . s-� 508-398-2231 ext. 1261 Fax 508-39&-0836
BUILDING DEPARTMENT
DEMOLITION DEBRIS DISPOSAL AFFIDAVIT
Pursuant to M.G.L. Chapter 40,Section 54 and 780 CMR, Chapter 1,Section 1 l l.5,
•
I hereby certify that the debris resulting from the proposed work/demolition to be
conducted at 310 LoN5 Ovti, A A I've
Work Address
Is to be disposed of at the following location: Z %1%\k k1 ,,x,Q ixte>rfunt. PIA 01`21 B o
Said disposal site shall be a licensed solid waste facility as defined by M.G.L.
Chapter 111, Section 150A.
PI „,„...4.,...),---
iz-z,: -Zo, S
Signa f Application Date
Permit No.
_ _
Office of Consumer Affairs&Business Regulation
HOME IMPROVEMENT CONTRACTOR
TYPE:Corporation
158439 01/04/2020
GO GREEN INDUSTRIES INC
STEPHEN CUZZIERE
2 DORM RD.
WESTFORD,MA 01886 Undersecretary
•
Commonwealth of Massachusetts
Division of Professional Licensure
• Board of Building Regulations and Standards
Constructbn Supervisor
CS-104385 E;Cpires: 04/18/2020
STEPHEN M GUZZIERE°4 3
2 DORIS ROAD. 4
WESTFORD MA°o111B6
Commissioner
O 11-002623793
This card acknowleckpa that the reoWent has successfully completed a
10.hoor Occtrpeliorrei Safety and Health listediII Course In
#tt Construes*Safer/and ifeefth
Phw`1 2,21 P�'
LGu 14Lt /4
charnay—prhN'mfy } (Ceases d
'' - S
9tX
structural
November 6,2019 ENGINEERS
Green Think Energy
PO Box 427
New York, NY,10027
Subject:Structural Certification for Installation of Solar Panels
Job Number:19-12310
Client: Lynnda Lgnacio-9572312
Address:310 Long Pond Drive,South Yarmouth,MA 02664
Attn.:To Whom It May Concern
A field observation of the condition of the existing framing system was performed by an audit team from Green Think Energy.
From the field observation of the property,the existing roof structure was observed as follows:
The existing roof structure consists of:
• Composition Shingle over Roof Plywood is supported by 2x8 @ 16"o.c.SPF#2 at ARRAY 1.The rafters are sloped at
approximately 23 degree and have a maximum projected horizontal span of 17 ft 0 in between load bearing supports.
Design Criteria:
• Applicable Codes=780 CMR,ASCE 7-10,and NDS-15
• Ground Snow Load=30 psf;Roof Snow Load=20.8 psf ARRAY 1
• Roof Dead Load=7.6 psf ARRAY 1
• Basic Wind Speed=142 mph Exposure Category C
As a result of the completed field observation and design checks:
• ARRAY 1:is adequate to support the loading imposed by the installation of solar panels and modules.Therefore,no
structural upgrades are required.
I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel
supports and modules had been reviewed and determined to meet or exceed the requirements without structural upgrade in
accordance with the 780 CMR.
If you have any questions on the above,do not hesitate to call.
Prepared By:
PZSE,Inc.-Structural Engineers
Roseville,CA
,1HOFA q iv
PAUL K.
4.1ZACHER
STRUCTURALNo.50100
� Ow 30.2 r A.
O SSLONAL'
1478 Stone Point Drive,Suite 190, Roseville, CA 95661
916.961.3960 916.961.3965 www.pzse.com
PHOTOVOLTAIC ROOF MOUNT SYSTEM r(GREEN
21 MODULES-ROOF MOUNTED - 6.720 kW DC, 5.04 kW AC THINK
310 LONG POND DRIVE, SOUTH YARMOUTH, MA 02664, USA --ENERGY
GREEN OF WORK: AHJ:BARNSTABLE CO. SHEET INDEX THINK ENERGY LLC
PV-1 SITE PLAN&VICINITY MAP 69 CHARLTON ST.
(N)21-LG ELECTRONICS LG320N1K-A5(320 W)MODULES
PV-2 ROOF PLAN WITH MODULES NEW YORK,NY 10014,USA
(N)21-ENPHASE:107-60-2-US(240V)INVERTER PV-3 ATTACHMENT DETAIL www.GrennThinkEnerpy.com
PV-4 SINGLE LINE DIAGRAM CONTRACTOR NAME
- 1 .p PV-5 WIRING CALCULATION
V 'P PVC PLACARDS BUSINESSN co "
GOVERNING CODES: O� �� PV-7• EQUIPMENT SPECIFICATION roue FS C.
ADDRESS 2 DORM ROAD.
ALL WORK SHALL COMPLY WITH THE CODES BELOW: �� " 1OR0'"'�01BB1'USA
AS
2009 MASSACHUSETTS ELECTRICAL CODE O\O •(jw REVISIONS
y� DEsc RIFTIDN DATE RCV
2009 MASSACHUSETTS RESIDENTIAL CODE
2009 MASSACHUSETTS BUILDING CODE G i
2009 MASSACHUSETTS ENERGY CODE
2009 MASSACHUSETTS PLUMBING CODE �O s �
2017 NATIONAL ELECTRICAL CODE 60
ADOPTED BY THE LOCAL GOVERNING AGENCIES. n , `. `, ARRAY LOCATION
• SIGNATURE&SEAL
GENERAL NOTES: FOR STRUCTURAL ONLY
• ALL PANELS,SWITCHES,ETC.SHALL / v, OF,t1q }�'HAVE SUFFICIENT GUTTER SPACE AND / ("0„-i'vk
LUGS IN COMPLIANCE TO UL '� PAUL K. 4y�.iT\REQUIREMENTS TO ACCOMMODATE ��Ei/ Gc ZACHER 'CONDUCTORS SHOWN v� �� �` TZACHE' \�1 y RAL a
• THIS SYSTEM WILL NOT BE �� fig"/ ,,, NG.�D1
INTERCONNECTED UNTIL APPROVAL Q 0-J A �? �G- PROJECT NAME
FROM THE LOCAL JURISDICTION AND THE QQO QQSg '
• UTILITY IS OBTAINED.THIS SYSTEM IS AN
UTIUTY INTERACTIVE SYSTEM WITH NO <\
STORAGE BATTERIES. • 0
ALL EXTERIOR ELECTRICAL DEVICES AND ;
EQUIPMENT INCLUDING THOSE THAT ARE \
EXPOSED TO OUTSIDE ENVIRONMENT `(E)UTILITY METER c : Q E _
SHALL BE WEATHERPROOF TYPE NEMA F-
3RANDSHALLBELISTEDBY'UL"FOR \ (N)ACDISCONNECT 0 HOUSE PHOTO Z o
THE TYPE OF APPLICATION AND"UL' v
LABEL SHALL APPEAR ON ALL \ (N)MA SMART GENERATION METER _ Z O 0
ELECTRICAL EQUIPMENT. \ SCALE:NTS _I a Ce ,d^
• WIRING METHOD SHALL BE EMT ABOVE .4(
0 Q O
GROUND MOUNTED IN COCONCEALEDIIIII Mi. • IQ7 60 2-US(240V)
0 Z > N
OTHERWISE)AND SCHEDULE-40 PVCSPACES(UNLESS APPROVED '".�,\ z ��r �f •INVERTER
Z _J F- O
FOR BELOW GROUND INSTALLATION • \ a' 1 �__„_ -- Z O D
UNLESS NOTED OTHERWISE. \ ''-;'" >. O
• AN OSHA APPROVED LADDER PROVIDING K J M (n
ACCESS TO ALL PORTIONS OF THE (N)LOAD CENTER •,
ARRAY SHALL BE SECURED IN PRIOR TO ,p PROJECT SITE
REQUESTING INSPECTION. �PQ\ • • PROPERTY LANE
• SOLAR MODULES MOUNTED ON ROOF -0 \
USING ALUMINUM RACKING SYSTEM. �-P _ SHEET NAME
SYSTEM WEIGHT:3 LB/FTSQ. 87'"1 .
ROOF#1Ili• CONNECT SYSTEM TO MAIN PANEL VIA ��y • ' (21)LG ELECTRONICS t 1(j !;( I.0(;/I !'-lq Ivt' SITE PLAN&
PV BREAKER,IF THE EXISTING MAIN LG320N1K-A5 320 MODULES VICINITY MAP
SERVICE PANEL DOES NOT HAVE (N)JUNCTION BOX
VERIFIABLE GROUNDING ELECTRODE,IT 3/4"EMT CONDUIT RUN(1/2 SHEET SIZE THE CONTRACTOR'S RESPONSIBILITY INCHES ABOVE ROOF) ANSI B
TO INSTALL A SUPPLEMENTAL
GROUNDING ELECTRODE. (E)MAIN SERVICE PANEL,200A _ 11"X 17"
RATED,240Va".
°SITE PLAN WITH ROOF PLAN A 0 VICINITY MAP SHEET NUMBER
SCALE: 1/32"=1' SCALE: NTS PV-1
MODULE TYPE,DIMENSIONS&WEIGHT ROOF DESCRIPTION BILL OF MATERIALS GREEN
(1)STRINGS OF 10 MODULES CONNECTED IN SERIES.
NUMBER OF PANELS IN ARRAY=21 MODULES (1)STRINGS OF 11 MODULES CONNECTED IN SERIES. ROOF TYPE COMP SHINGLE EQUIPMENT DIY DESCRIPTION
MODULE TYPE=LG ELECTRONICS LG320N1K-A5(320W)MODULES - - ROOF RAFTERS RAFTERS SOLAR PV MODULE 21 LG ELECTRONICS LG320NIK-A5 320 MODULES THINK
NUMBER OF CONNECTIONS TO ROOF=46 ROOF AZIMUTH
TILT SIZE SPACING
WEIGHT OF INDIVIDUAL PANEL=39.68 LBS/18.0 KG. - INVERTERS 21 ENPHASE:107-60-2-US(240V)INVERTER 4m.ENERGY
MOUNTING SYSTEM WEIGHT:1.5 LBS.PER MODULE #1 23° 175° 248 16"o.G.
TOTAL WEIGHT OF ARRAY:864.78 LBS. AC DISCONNECT AC DISCONNECT:
WEIGHT AT EACH CONNECTION :864.78 LBS/46=18.80 LBS ARRAY AREA&ROOF AREA CALC'S SQUARE D NEMA 3R,30A,2P 120/240VAC
SOLAR PANEL AREA =66.38"X 40"=18.44 SF ROOF LOAD CENTER 1 ENPHASE AC COMBINER BOX,100AMP GREEN THINK ENERGY LLC
TOTAL ARRAY AREA=21 X 18.44=354.8 #OF ARRAY ROOF AREA 69 CHARLTON ST.
ROOF AREA AREA COVERED MA SMART METER 1 MA SMART GENERATION METER NEW YORK,NY 10014,USA
DISTRIBUTED LOAD =864.78/354.8=2.23 PSF G MODULES (Sq.FL) (Sq.Ft.) BY ARRAY
ATTACHMENT 46 SNAPNRACK L-FOOT ATTACHMENTS www.Grn:nThinkEnerpy.cnm
DESIGN CRITERIA ^ )
O CONTRACTOR NAME
• SEISMIC CATEGORY=B #1 21 387.03 1055.06 36.68 RAILS 10 SNAPNRACK STANDARD RAIL 162"
RUMNESS NAME:GO GREEN
INDUST• WIND SPEED=142MPH \O 0O ADD BROAD.
• SNOW LOAD=30PSF RAILS 16 SNAPNRACK STANDARD RAIL 122"
O wMslraRD,MA OMB.IAA
N RAIL SPLICE 6 SPLICE KIT
CI Or.
MID CLAMPS 36 MID CLAMPS REVISIONS
�\ \ END CLAMPS 12 END CLAMPS O :II r:JN DATE
O O GROUNDING LUG 3 WEEBLUG
(E)UTILITY METER (i�
`.. SIGNATURE&SEAL
(N)AC DISCONNECT "I
(N)MA SMART GENERATION METER
PROJECT NAME
OG
a ce _
o �
rZ^ 0D
-_ 10.-0„ j 0 2
—28 11 cc 4.
FOR EXISTING ROOF AND 1s 6 � � � 0 Z }' NROOF ATTACHMENT ONLY OjZ11111111111iiiI; ttIITLILu
, } MO
r
PAUL K. SNAPNRACK STANDARDRAIL ZACHER `b+r - - _STRUCTURAL - (N)48 SNAPNRACK L FOOT
No.501Q0 / ATTACHMENTS(c�48"O.C. ' 15111111!1111111
�� r�e` 815HEET NAME
\/ONAL/ ��i1 ,f 116...N NG#,NG#2 ROOF#1111" ROOF PLAN WITH
(N)LOAD CENTER (N)JUNCTION BOX (21)LG ELECTRONICS MODULES
• ALL EQUIPMENT AND CONDUITS SHALL BE 3/4"EMT CONDUIT RUN(1/2 LG32ON1K-A5 320 MODULES
PAINTED TO MATCH THE BACKGROUND INCHES ABOVE ROOF) SHEET SIZE
(N)21-ENPHASE:(07-60-2-US ANSI B
COLOR OF THAT LOCATION. (E)MAIN SERVICE PANEL,200A (240V)INVERTER 11"X i r
RATED,240V (E) BACK YARD
SHEET
la ROOF PLAN WITH MODULES �' EET NUMBER
SCALE: 3)32"= 1'-0" PV-2
(E)ONE LAYER OF COMP. GREEN
SHINGLES THINK
:1.'4'
:ENERGY
PV MODULE GREEN THINK ENERGY LLC
69 CHARLTON ST,
NEW YORK,NY 10014,USA
www.Gree nTAinkEnergy.com
CONTRACTOR NAME
r. !x8.!ERS!6OC
BUSINESSO GREEN
PREVISIONS ,_
L[yc"I F l,II DATI. REV
—I
401'
SEE(2/PV-4)FOR SIGNA I URE A SEAL
ENLARGED VIEW
Q ATTACHMENT DETAIL
- SCALE: NTS
PRO IL(T NAME
SNAPNRACK CHANNEL NUT GROUNDING
END/MID CLAMP
#1111111.Illjp-PIIIP
O > 2
PV MODULE SNAPNRACK STANDARD RAIL U _
Z ang
\doe 0 zop
__I 0 2
AWZZ Z =}
o
�;/ ' SINGLE LAYER OF COMP Z O =
SHINGLE ROOF
FOR EXISTING ROOF AND }I
ROOF ATTACHMENT ONLY SNAPNRACK COMPOSITION —I CO 0
/�
L-FOOT CAN BE J,► FLASHING
MOUNTED IN ANY ORIENTATION /
) PAUL K. SNAPNRACK COMPOSITION i 5/16'x3.5'SS LAG BOLT WITH
"• ZACHER FLASHING MIN 2Y"THREAD EMBEDMENT, SHEET NAME
STRUCTURAL ti SEALED PENETRATION ATTACHMENT
\ No.soloo DETAIL
b.)°•• 2"x8"RAFTERS @ 16°OC
" S�ONAL�� SHEET SIZE
ANSI B
11"X17"
®ATTACHMENT DETAIL (ENLARGED SECTION VIEW) SHEET NUMBER
SCALE: NTS PV-3
Nutt: Nutt:
SYSTEM SUMMARY(6.72 kW DC/5.04 kW AC) • ALL GROUNDING TO COMPLY WITH NEC 690.47, PROPERLY INSTALLED SYSTEM MEETS THE• GREEN
ROOF TOP CONDUIT SHALL BE LOCATED MIN.1l2' REQUIREMENTS OF NEC 690.35 FOR UNGROUNDED
(21)LG LG320N1 K-A5 MODULES ABOVE ROOF SURFACE. PV POWER SYSTEMS.PROVIDE EQUIPMENT
•1x STRING OF 10 CONNECTED IN PARALLEL • ALL TERMINALS SHALL BE MIN.75 DEG.C RATED. GROUNDING PER MANUFACTURERS K THIN
REQUIREMENTS IN COMPLIANCE WITH THE NEC. A
•1x STRING OF 11 CONNECTED IN PARALLEL
-(21)Enphase IQ7-60-2-US MICROINVERTERS :ENERGY
GREEN THINK ENERGY LLC
69 CHARLTON.ST,
NEW YORK.NY 10014.USA
www.GreenThinkEnerpy.c4n1
CONTRACTOR NAME
MOD:LG LG320N1K-A5 MAIN SERVICE PANEL
INV:Enphase IQ7-60-2-US (EXISTING,BOTTOM-FED) SUSIIESS HALE:GO GREEN
INDUSTRIES INC.
( ) ADDRESS:
1 STRINGS X 10 MICROINVERTERS PV SYSTEM BUS RATING:200A ADDRESS I DORIS ROAD.
RD,MA OfNW USA
BLADED UTILITY MAIN BREAKER:200A(E)
DISCONNECT RE VISIONS
° ° 10 30A °Cic RtFiiON I>Are aeV
JUNCTION BOX AC COMBINER PANEL SWITCH
• 600V,NEMA 3 XAM1-120(OR EQUIV) LC-01 (30A UNFUSED __ _,_
7 MSTR-01 UL LISTED 1PH 240VAC) ____,--�- _____
» ------ -j LC-01 CB-01 15A l MO �. LC-01 �-,____ SIGNATURE a SEAL
MOD:LG LG320N1K-A5 CB-02 ........_,--._1UTILITY METER
INV:Enphase IQ7 60-2-US 15A J --,__ METER NO:XXXXX
(1 STRINGS X 11 MICROINVERTERS) DEDICATED I ON IOFFI UTILITY:XXXXX
PV V _�-, SERVICE:240V 60HZ 1PH
METER
o o II (240V) 200A TO
FORM 0- UTILITY
2S GRID
•
PROJECT NAME
MSTR-02 MA y
----- SMART
METER
O ><
Q f _
0
a co
ZO
J O
co
GI Z } N
AC wire details Z O = O
#Modules Max Current Nominal Total Conductor ccConductors Expected Temp Conduit fill Min OCPD Conductor&neutral EGC size Conductor Insulation Max V drop Min EMT Min PVC Min RMC J I-
WirelD /cond.set Voltage Power sets /conduit max temp Berate Berate /COS set size metal length size size size Z O 0
MSTR-01 10 - 10.0 A 240 V 2.4 kW 1 2 40 0.91 1.00 15 A AWG 10 AWG 10 Cu PV 50 ft 0.44% 0.75 in 0.75 in 0.75 in J M L7
MSTR-02 11 11.0 A 240 V 2.6 kW 1 2 40 0.91 1.00 - 15 A AWG 10 -AWG 10 Cu PV 50 ft 0.49% 0.75 in 0.75 in 0.75 in
CB-01 10 10.0 A 240 V 2.4 kW 1 ' 2 40 0.91 1.00 15 A AWG 10 AWG 10' Cu THWN-2 50 ft 0.44% 0.50 in ' 0.50 in 0.50 in
CB-02 11 11.0 A 240 V 2.6 kW 1 2 40 0.91 1.00 15 A AWG 10 AWG 10 Cu THWN-2 50 ft 0.49% 0.50 in 0.50 in 0.50 in
LC-01 21 21.0 A 240 V 5.0 kW 1 2 40 0.91 1.00 30 A AWG 10 AWG 10 Cu THWN-2 10 ft 0.19% 0.50 in 0.50 in 0.50 in
SHEET NAME
INTERCONNECTION SINGLE LINE
1 20%RULE(MAIN PANEL) EXTREME E CAS SE E MODULE DULE OUTPUT DIAGRAM
LUTILITY FEED+SOLAR BACKFEED Isc(25'C)=10.19A,Tisc=0.030%1"C
200A+30A=230A SHEET SILE
Isc(T)=Isc(25°C)x(1+T sc x(T-25°C)j
LESS OR EQUAL TO Isc(-14°C)=10,07A,Isc(40`C)=10.24A ANSI B
BUS RATING X 120% 11•X 17N
0 E L E C T R I C A L SINGLE LINE DIAGRAM 200A x 120%=240A Voc(25"C)=40.80V,Tvoc=-0.270%/"C SHEET NUMBER
Voc(T)=Voc(25°C)x[1+Tvoc x(T-25°C)( ,1
SCALE: NTS CALCULATION ENSURES BUS IS Voc(-14"C)=45.10V,Voc(40"C)=39.15V PV-4
SAFE REGARDLESS OF LOADS
11/6/2019 Ignacio Signed Contract.JPG
0 W
EL - RICAL .
This quote includes the following:
1) Project Design, Engineering, Permitting, & Utility co. submittals
2) Supply & Install 21-320w Triple Black LG Solar Modules w/ 12 yr.
warrantee
3) 21 Enphase IQ7 Micro-inverters w/ 25 year warrantee.
4) 10 year workmanship warranty
5) Critter guard around array
6) Simple Post Rebate Return on investment (based upon PV watts and FEC
site survey worksheet = 5.19 years.
7) Additional details available upon request.
This quote is good for 30 days.
n \s.: i --" \ / ,3 A
.iip / 0/28/
4/ , I - '—'7"--)
- r ' c-e..-c__, /c/2-gh .
Thank you for the opportunity to quote this work. If you have any questions, I can
be best reached on my mobile device at 508-328-1901
FocusElectrical@comcast.net
. 2