2015 IECC R406 Confirmed ERI Report - 6 Smiths Point W Yarmouth
2015 IECC R-406 Confirmed Energy Rating Index Report Property Builder: Patrick Coffey Address: 6 Smith's Point Road West Yarmouth, MA 02673 Organization Company: Cape Cod HERS Raters Phone: (508)737-8011 Rater: Chris Picariello Energy Rating Index Information Confirmed Rating No:089 Rater ID:6397177 Date Rated: 2020-06-15 REM/Rate - Residential Energy Analysis and Rating Software v16.0.2 This information does not constitute any warranty of energy costs or savings. © 1985-2020 NORESCO, Boulder, Colorado. 49 Estimated Annual Energy Consumption* Rated Home Calculated Energy Use (MBTU) Rated Home Cost ($/yr) Heating 57.8 1714 Cooling 1.1 47 Water Heating 8.2 243 Lights & Appliances 25.2 1045 Photovoltaics -0.0 -0 Total 92.3 3129 *Based on standard operating conditions ERI with PV:49 ERI without PV 49 Annual Estimates Electric(kWh):7058 C02 Emissions(Tons):8 Propane(Gallons):747 Energy Savings ($)**:2935 **Based on the 2015 IECC Energy Rating Index Reference Design Home Maximum Energy Rating Index: 55 This Home's Energy Rating Index: 49 PASS This home MEETS the Energy Rating Index Score requirements of Section 406 of the 2015 Internation Energy Conservation Code based on a climate zone of 5A. In addition to the Energy Rating Index other mandatory measures must be met. (See Mandatory Requirements on second page.) Name Chris Picariello Signature Organization Cape Cod HERS Raters Date 21 June 2020 Provider Data and Seal Chris Picariello Cape Cod HERS Raters PO Box 1010 South Yarmouth, MA 02664 (508)737-8011 To determine if a provider is properly accredited go to : www.resnet.us/professional/programs/search_directory 2015 IECC R-406 Confirmed Energy Rating Index Report REM/Rate - Residential Energy Analysis and Rating Software v16.0.2 This information does not constitute any warranty of energy costs or savings. © 1985-2020 NORESCO, Boulder, Colorado.Page 2 of 2 Climate Zone 5A Mandatory Requirements (Confirmed and tested) Provision Number Topic Compliance Decision 2009 IECC Table 402.1.1 or 402.1.3 Building thermal envelope minimum insulation levels and maximum fenestration U-factor and SHGC PASS R401.3 Post a permanent certificate listing the level of efficienceies installed in the house Certificate required for CO R402.4 Envelope air leakage maximum leakage rate (3 ACH50 for CZ3-8) PASS R402.4.1/Table R402.4.1.1 Comply with air sealing and insulation requirements in Table R402.4.1.1 Checklist required for CO R402.4.4 Rooms containing fuel-burning appliances PASS* R402.5 Maximum fenestration U-factor and SHGC PASS R403.1.2 Heat pump controls PASS* R405.2 Ducts outside of conditioned space to be insulated to a minimum of R-6 PASS R403.3.2 Duct sealing on all ducts PASS* R403.3.3 Duct testing for ducts in unconditioned space PASS R403.3.5 Building cavities not used as ducts PASS* R403.5.1 Heated water circulation and temperature maintenance systems comply PASS* R403.5.3 Hot water pipe insulated to R-3 PASS* R403.6 Mechanical ventilation meeting the requirements of the IRC or IMC. Outdoor air and exhaust dampers installed PASS* R403.7 ACCA Manual J and S conducted for all heating and cooling systems ACCA Forms Required for permit R403.8 Systems serving multiple dwelling units to meet the mechanical requirements of the IECC commercial Does Not Apply R403.9 Snow melt and ice system controls installed where applicable PASS* R403.10 Pools and permanent spa energy consumption meet requirements for heaters, time clocks and covers PASS* R403.11 Portable spas meet the requirements of APSP-14 PASS* R404.1 High efficacy lights installed in 75% of permanently installed fixtures PASS *Rater has verified that all systems are in compliance with IECC rules.