HomeMy WebLinkAbout114 Clear Brook SOLAR PANEL DESIGNGOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1.2015 INTERNATIONAL RESIDENTIAL CODE 2.2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION a.2020 NATIONAL ELECTRICAL CODE b.ANY OTHER LOCAL AMENDMENTS MA LICENSE: HIC-170848, ME-15688A, SS-002342 JURISDICTIONAL NOTES: GENERAL STRUCTURAL NOTES: a.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ROCK-IT SYSTEM BY ECOFASTEN. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. b.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 516" LAG SCREWS WITH A MINIMUM OF 2 12" PENETRATION INTO ROOF FRAMING. c.THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM. d.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. e.GROUND SNOW LOAD = 30 psf f.WIND SPEED = 140 mph g.EXPOSURE CATEGORY = B COVER SHEET 1800 ASHTON BLVD. LEHI, UT, 84043 1.877.404.4129 vivint.Solar FRASIER RESIDENCE 114 CLEAR BROOK RD WEST YARMOUTH, MA, 02673 UTILITY ACCOUNT #: 1428 208 0044 SERVICE #: S-6298037 DATE: 1/29/2020 DRAWN BY: DIN REGIONAL OPERATING CENTER: MA-03 SHEET INDEX: PV 0.0 - COVER SHEET PV 1.0 - SITE PLAN S 1.0 - MOUNT DETAILS E 1.0 - ELECTRICAL DIAGRAM E 2.0 - ELECTRICAL NOTES E 3.0 - WARNING LABELS E 4.0 - WARNING LABEL LOCATIONS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SYSTEM SIZE - 4.160kW DC | 3.800kW AC MODULE TYPE & AMOUNT - (13) Jinko Solar JKM320M-60HBL WITH 13 SolarEdge P340 OPTIMIZERS MODULE DIMENSIONS - (L/W/H) 66.3"/ 39.45"/ 1.38" INVERTER - (1) SolarEdge Technologies SE3800H-US000BNC4 INTERCONNECTION METHOD (GRID-TIED) - LOAD BREAKER GENERAL ELECTRICAL NOTES: a.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. b.ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE CORRECTED ON INSTALLATION. c.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE d.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. e.SEE *E 1.0 AND *E 2.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. NPV 1.0 SYSTEM LEGEND vivint.Solar FRASIER RESIDENCE 114 CLEAR BROOK RD WEST YARMOUTH, MA, 02673 UTILITY ACCOUNT #: 1428 208 0044 SITE PLAN SCALE: 3/16" = 1'-0" PV STRING(S): #1) 13 MODULES 1.877.404.4129ACEXISTING INTERIOR MAIN SERVICE PANEL POINT OF INTERCONNECTION TIED TO DETACHED UTILITY METER #2805115. M I NEW PV SYSTEM AC DISCONNECT. LOCATED WITHIN 10' OF MSP. P NEW SMART METER. LOCATED WITHIN 10' OF MSP. │ 3.800kW AC PV SYSTEM SIZE: NEW 4.160kW DC 13 NEW JINKO SOLAR JKM320M-60HBL MODULES. NEW SOLAR EDGE P340 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE. 1 NEW PV SYSTEM INVERTER: SolarEdge Technologies SE3800H-US000BNC4 (RSD EQUIPPED) NEW JUNCTION BOX. (MOUNTED WITH SOLADECK) NEW PV CONDUIT RUN.*SEE EE1.0 CONDUIT SCHEDULE = EXTERIOR RUN = ATTIC RUN ROOF SECTION(S): 1 SLOPE - 26 AZIMUTH - 238 MATERIAL - COMPOSITION SHINGLE 2 SLOPE - 26 AZIMUTH - 238 MATERIAL - COMPOSITION SHINGLE SERVICE #: S-6298037 DATE: 1/29/2020 DRAWN BY: DIN REGIONAL OPERATING CENTER: MA-03 EXISTING DETACHED UTILITY METER: # 2805115 114 CLEAR BROOK RD FRONT OF HOUSE. 1 2 M IACP 5/16"x3/8" HEX FLANGE BOLT 300 SERIES SS SIDE VIEW MIN 5/16" DIAM SS LAG SCREW TORQUE=13±2 FT-LBS. COMP SHINGLES METAL FLASHING ROCK-IT SLIDE METAL FLASHING COMP SHINGLES ROCK-IT COUPLING MID CLAMP ROCK-IT PEDESTAL SS LAG SCREW TORQUE=13±2 FT-LBS. EPDM BONDED WASHER FORMS WATERTIGHT SEAL 2 S 1.0 SECTION VIEW ROCK-IT SLIDE SIDE VIEW TOP VIEW ROCK-IT 3.0 COUPLING MID CLAMP ROCK-IT COUPLING SHELF TIE PLATE 5/16"x1 1/2" HEX FLANGE BOLT 300 SERIES SS 2 1/2" MIN COUPLING CLAMP + ATTACHMENT COUPLING CLAMP + ATTACHMENT L=PORTRAIT CLAMP SPACING PERMITTED CLAMP SPACING MODULE L=LANDSCAPE CLAMP SPACING MODULE MODULE COUPLING RAFTER CLAMP RAFTER CANTILEVER L/3 OR LESS RAFTER S 1.0 5 MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALES 1.0 4 PV SYSTEM MOUNTING DETAIL NOT TO SCALE S 1.0 3 SECTION VIEW NOT TO SCALE S 1.0 6 PV ARRAY TYP. ELEVATION NOT TO SCALE PV MODULE, TYP. MOUNT TO FRAMING OF EXISTING ROOF TYPE, PARALLEL WITH PLANE OF ROOF 1 S 1.0 S 1.0 7 CONDUIT MOUNTING DETAIL NOT TO SCALE 3" MIN AND 6" MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE CONDUITONE HOLE STEEL STRAP CONDUIT MOUNT BRACKET FLASHING OR TILE STRAP 6" MAXIMUM U.L. LISTING FOR ECOFASTEN: 2703 WEIGHT: 2.3 lb. LANDSCAPE=MAX 48" (4'-0") PORTRAIT=MAX 48" (4'-0") TRUSS 2"x4" AT 24" O.C. S 1.0 8 ILSCO SGB-4 GROUNDING LUGS NOT TO SCALE 1 1/2" ISOMETRIC VIEW ROCK-IT COUPLING MID CLAMP ROCK-IT COUPLING SHELF S 1.0 2 ROCK-IT COUPLING ASSEMBLY NOT TO SCALE S 1.0 1 ROCK-IT MOUNT DETAIL NOT TO SCALE S 1.0 MOUNTING LEGEND vivint.Solar MOUNT DETAILS SCALE: NOT TO SCALE FRASIER RESIDENCE 114 CLEAR BROOK RD WEST YARMOUTH, MA, 02673 UTILITY ACCOUNT #: 1428 208 0044 1.877.404.4129 SERVICE #: S-6298037 DATE: 1/29/2020 DRAWN BY: DIN REGIONAL OPERATING CENTER: MA-03 Tag Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size 1 DC-to-DC Converter Output (PV Wire)10 AWG 2(V+, V-) B/R Free Air N/A 1 EGC (Bare)6 AWG 1 BARE Free Air N/A 2 DC-to-DC Converter Output (THWN-2)12 AWG 2(V+, V-) B/R FMC 1/2" 2 EGC (THWN-2)12 AWG 1(GRN)FMC 1/2" 3 DC-to-DC Converter Output (THWN-2)12 AWG 2(V+, V-) B/R EMT 1/2" 3 EGC (THWN-2)12 AWG 1(GRN)EMT 1/2" 4 Inverter Output (THWN-2)12 AWG 3(L1, L2, N) B/R/W EMT 1/2" 4 EGC (THWN-2)12 AWG 1(GRN)EMT 1/2" SHEET NUMBER:E. 16298037MA LICENSE: 170359INSTALLER NUMBER: 1.877.404.4129INSTALLER: VIVINT SOLAR3-Line DrawingSHEET NAME: Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper)Created: 1/29/20Frasier Residence114 CLEAR BROOK RDWEST YARMOUTH, MA 02673Utility Account:1428 208 0044Photovoltaic System DC System Size (Watts) AC System Size (Watts) Total Module Count 4160 3800 13 ALL STICKERS SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. ALL PLACARDS SHALL BE WEATHER SolarEdge SE3800H-US *Conforms to ANSI C12.1-2008 413 13 PV MODULES PER INVERTER = 4160 WATTS STC STRING 1: 13 PV MODULES W/OPTIMIZERS 3 4 1 NEMA 4 Junction Box 2 PV System SMART Meter 4 Existing Murray 240V/125A Service Panel, Single Phase, with 100A Main Disconnect Visible/Lockable 'Knife' AC Disconnect 4 Minimum GEC size 6 AWG copper 20A Point of Interconnection, Load Side 705.12(B)(3)(2) 100A Rapid Shutdown Disconnect, Square D DU221RB 240V/30A Unfused, NEMA3, with 75° C terminations Frasier Residence114 CLEAR BROOK RDWEST YARMOUTH, MA 02673Utility Account:1428 208 0044SHEET NAME:Created: 1/29/20INSTALLER: VIVINT SOLARINSTALLER NUMBER: 1.877.404.4129MA LICENSE: 170359Notes PageSHEET NUMBER:E. 26298037Optimizer SolarEdge P340 DC Input Power 340 Watts DC Max. Input Voltage 48 Volts DC Max. Input Current 13.75 Amps DC Max. Output Current 15 Amps Max. string rating inverter dependent. See SE documents. Inverter Make/Model PV Module Rating @ STC Module Make/Model Jinko Solar JKM320M-60HBL Max. Power-Point Current (Imp)9.59 Amps Max. Power-Point Voltage (Vmp)33.4 Volts Open-Circuit Voltage (Voc)40.9 Volts Short-Circuit Current (Isc)10.15 Amps Max. Series Fuse (OCPD)20 Amps Nom. Max. Power at STC (Pmax)320 Watts Max. System Voltage 1000 VDC (UL/IEC) Voc Temperature Coefficient -0.28 %/C AC Output Current According to art. 690.8(B)(1)16 Amps Nominal AC Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Rooftop conductor ampacities designed in compliance with art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9. Location specific temperature obtained from ASHRAE 2017 data tables. ASHRAE 2017 -BARNSTABLE MUNICIPAL Highest Monthly 2% D.B. Design Temp.: 29.5 °C Lowest Min. Mean Extreme D.B.: -19.2 °C SolarEdge SE3800H-US CEC Efficiency 99 % AC Operating Voltage 240 Volts Cont. Max Output Current 16 Amps DC Max Input Current 10.5 Amps Input Short Circuit Current 45 Amps Max Output Fault Current 17.5 A/20 ms Conductor Calculations OCPD Calculations Other Notes Wire gauge calculated from 310.15(B)(16) & (17) with ambient temperature calculations from 310.15(B)(2)(a) & 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B)(3)(a). Conduit on the roof shall be installed no less than 1” above the roof deck. "Under Array" conductors use the 90°C ampacity in 310.15(B)(17) with relevant ambient temperature adjustments. PV Circuit conductors use the larger ampacity in 310.15(B)(16) or (17) using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments and without the continuous duty uprating per 690.8(B). Non-PV Circuit conductors use the ampacity in 310.15(B)(16) in the 75°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. More information about conductor calculations can be provided upon request. Calc. Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current (Tag 1 Under Array): DC-to-DC Converter Output: 10 AWG rated 55 A, 55 A x 1 x 1 = 55 A >= 15 A (Tag 2 Attic): DC-to-DC Converter Output: 12 AWG rated 20 A, 20 A >= 18.75 A (Tag 3 On Roof): DC-to-DC Converter Output: 12 AWG rated 20 A, 20 A >= 18.75 A (Tag 4 Exterior): Inverter Output: 12 AWG rated 20 A, 20 A >= 20 A Breakers sized according to continuous duty output current. PV circuit nominal current based off inverter continuous output current X (1.25[art. 690.8(A)]). Inverter 1: SE3800H-US Max Output = 16 A x 1.25 [art. 690.8(A)] = 20 A <= 20 A (OCPD) system output current w/ continuous duty = 20 <= 20A (System OCPD) • Designed according to and all code citations are relevant to the 2020 National Electrical Code. • All interior raceways carrying DC current shall be metallic. SHEET NAME:6298037Warning Labels PageSHEET NUMBER:E. 3INSTALLER: VIVINT SOLARINSTALLER NUMBER: 1.877.404.4129MA LICENSE: 170359Frasier Residence114 CLEAR BROOK RDWEST YARMOUTH, MA 02673Utility Account:1428 208 0044Created: 1/29/20CAUTION: MULTIPLE SOURCES OF POWER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNETS LOCATED AS SHOWN AT: METER AND MAIN SERVICE AC DISCONNECT DC DISCONNECT INVERTER ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. ALL PLACARDS SHALL BE WEATHER-RESISTANT, PERMANENTLY ETCHED PLACARDS. HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE. Conduit, Raceways, and J-Boxes (Labeled Every 10') per 690.31(D)(2) PHOTOVOLTAIC POWER SOURCE Interactive System Point of Interconnection per 690.54 PHOTOVOLTAIC AC POWER SOURCE RATED AC OUTPUT CURRENT: 16 A NOM. OPERATING AC VOLTAGE: 240 V PV System Disconnects per 690.13(B) PV SYSTEM DISCONNECT All Disconnecting Means per 690.13(B) & 690.15(D) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Power Source Output Connection, Adjacent to Back- fed Breaker per 705.12 WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Rapid Shutdown Switch per 690.56(C)(3) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM SE3800H-US String 1 DC Disconnecting Means per 690.53 PHOTOVOLTAIC DC POWER SOURCE DISCONNECT STRING 1 MAXIMUM VOLTAGE: 380 V Plaques and Directories at the Service Equipment (MSP) and the Location of All System Disconnects per 690.56(B) & 705.10 PV With Rapid Shutdown, Installed Within 3 ft of the Service Disconnecting Means per 690.56(C) ALL STICKERS BE REFLECTIVE, THEY SHALL CONTAIN NO SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. ALL PLACARDS SHALL BE WEATHER NOT BE ACCEPTABLE. SHEET NAME:Warning Labels PageSHEET NUMBER:E. 4INSTALLER: VIVINT SOLARINSTALLER NUMBER: 1.877.404.4129MA LICENSE: 1703596298037Frasier Residence114 CLEAR BROOK RDWEST YARMOUTH, MA 02673Utility Account:1428 208 0044Created: 1/29/20DC DISCONNECT INSIDE M M 8 96 3 5 6 3 5 42 5 10 77 4 12 ROOFTOP ARRAY EVERY 10' AND JUNCTION BOX SOLAR INVERTERS (MAY BE ON ROOFTOP INTEGRATED WITH ARRAY) COMBINER PANEL (WHEN USED) VISIBLE/LOCKABLE A/C DISCONNECT (WHERE REQUIRED) VIVINT SOLAR METER (WHERE REQUIRED) VISIBLE/LOCKABLE A/C DISCONNECT INSIDE PANEL SUB PANEL (WHEN REQUIRED) MAIN SERVICE DISCONNECT PANEL IF APPLICABLE ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. ALL PLACARDS SHALL BE WEATHER-RESISTANT, PERMANENTLY ETCHED PLACARDS. HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE. IF APPLICABLE INSIDE PANEL IF APPLICABLE TYPICAL SOLAR GENERATION INSTALLATION (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) 1 2 3 4 5 6 7 8 9 10 *** -value calculated for each account, for specific value see the previous warning label page THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT (DC)CONDUIT, ENCLOSURES, RACE-WAYS, CABLE ASSEMBLIES, JUNCTION BOXES COMBINER BOXES, AND DISCONNECTS TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT (3048 MM), ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS. MAIN BREAKER DE-RATED TO *** DUE TO SOLAR CIRCUITS MAX OF ***AMPS PV SOURCE ALLOWED DO NOT INCREASE MAIN BREAKER RATING Property of Vivint Solar WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Property of Vivint Solar PV SYSTEM DISCONNECT Property of Vivint Solar PHOTOVOLTAIC AC POWER SOURCE RATED AC OUTPUT CURRENT: *** A NOM. OPERATING AC VOLTAGE: ***V Property of Vivint Solar WARNING:PHOTOVOLTAIC POWER SOURCE Property of Vivint Solar WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Property of Vivint Solar RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM Property of Vivint Solar PHOTOVOLTAIC DC POWER SOURCE DISCONNECT MAXIMUM VOLTAGE:*** A MAXIMUM CURRENT: ***V DC-TO-DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: ***A Property of Vivint Solar SITE PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE AND DISCONNECT LOCATIONS. PLACARD SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL PANEL Property of Vivint Solar PV rapid shutdown label required by 690.56(C)(1) indicated on E.3