HomeMy WebLinkAboutMAX MEDIUM DENSITY CCTDS V1.1 April 1,2020
MAX
Insulation of the Future
Medium Density • Closed Cell Spray Foam Insulation
TECHNICAL DATA SHEET
Material Specication Criteria | Project Submittal Data
Thermoseal MAX
ThermoSeal MAX is a two component, semi-rigid, medium density, 1.7 lb closed cell polyurethane foam insulation
system which simultaneously insulates and air-seals your building structure. Thermoseal MAX requires the use of an
“A” component (ISO) and a blended “B” component (RESIN), which contains ZERO ozone depleting catalysts, polyols
and re retarding materials. ThermoSeal MAX is designed for residential, commercial, and industrial building
applications to make structures more energy ecient, quieter, healthier and more comfortable. ThermoSeal MAX is
applied as a liquid spray and lls all building cavities completely sealing all cracks, crevices, and voids where air loss
and inltration are most common.
Physical Properties
Property Value Test Method
R-Value 6.9 @ 1”/21.0 @ 3”ASTM C 518
Core Density 1.7 LB / Cubic Foot ASTM D 1622
Closed Cell Content >= 90%ASTM D 2586
Water Vapor Transmission - Permeance Perms: .8 @ 1” / .23 @ 3.5”ASTM E 96
Tensile Strength (PSI)50 ASTM D 1623
Dimensional Stability < 9%ASTM D 2126
Fire Properties
Property Value Test Method
Surface Burning Charateristics Class 1 Pass
<25 / <450 ASTM E 84• Flame Spread / Smoke Index
Ignition Barrier ICC- ES AC377
Appendix X
Thermal Barrier NFPA 286
• In Process
• In Process
Building Code Certications
Evaluation Report TBD
Thermoseal, llc
Po Box 32
New Canaan, CT. 06840
www.ThermoSealUSA.com
800.853.1577
info@ThermosealUSA.com
IAPMO
Compressive Strength (PSI)43 ASTM D 1621
Air Leakage Rate Zero (0) ft3/s.ft2 @ 75Pa ASTM E 283
Sound Transmission Coecient 41 ASTM E-90-85/E 413
UL 1715
TDS V1.1 April1, 2020
DISCLAIMER: To the best of our knowledge, all technical data contained herein is true and accurate as of the date of issuance and subject to change without prior notice. User
must contact Thermoseal, llc to verify correctness before specifying or ordering. We guarantee our products to conform to the quality control standards established by
Thermoseal, llc. We assume no responsibility for coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of the product. NO OTHER
WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY THERMOSEAL USA EXPRESSED OR IMPLIED; STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Recommended Processing Parameters
Recirculation Target Do not recirculate. Gradually warm drums to 77˚F prior to use.
Primary Heater Target (Initial)
125˚F
125˚F 52˚C
Primary Hose Target (Initial)52˚C
Target Processing Pressure 1200 psi 8274 kPa
Substrate & Ambient Temp >14˚F (Winter)/ >45 ˚F (Summer) >-10˚C (Winter)/ >7 ˚C (Summer)
Moisture Content of Substrate <20%<20%
• Must be clean and free of dust and debris
Moisture Content of Concrete <10%<10%
TECHNICAL DATA SHEET
Material Specication Criteria | Project Submittal Data
Thermoseal, llc
Po Box 32
New Canaan, CT. 06840
www.ThermoSealUSA.com
800.853.1577
info@ThermosealUSA.com
Storage and Processing Information
Thermoseal MAX
Liquid Component Properties
Property A Side - PMDI B Side- Thermoseal MAX
Color Brown Amber
Viscosity @ 77˚F (25˚C)185 - 230 cps 400-520 cps
Specic Gravity 1.25 1.17 - 1.19
Storage Temperature 50˚F-75˚F ( 10˚C-24˚C)50˚F-75˚F ( 10˚C-24˚C)
Mixing Ratio (By Volume)1:1 1:1
• Of unopened drums stored within
specied range
Shelf Life 1 Year 18 Months
MAX
Insulation of the Future
Processing - Application processing temperatures can vary and are dependent upon indoor ambient temperature,
outdoor ambient temperature, substrate temperature, humidity, elevation, substrate type, equipment, and other factors.
While manufacturing polyurethane foam plastic on site, the applicator must continuously observe the characteristics of the
sprayed foam and adjust the processing temperatures and pressures to maintain optimal cell structure, adhesion, and overall
foam quality. It is the sole responsibility of the applicator to manufacture Thermoseal polyurethane foam plastic on-site within
our specications. When applying Thermoseal, all substrates must be 10 ˚F degrees above the dew point and free of all debris
including frost, oil, rust, dust, or other debris. The equipment being used must be set to deliver a consistent 1:1 ratio by volume
and must be capable of achieving at least 1200 psi and the target processing temperatures outlined in this manual. To maintain
warranty status on all Thermoseal products, the Applicator’s Thermoseal Training Certicate must be current. Thermoseal
Training is free and can be conducted on our website at http://www.ThermosealUSA.com.