HomeMy WebLinkAbout20200921_A1.1_Revision 2_cleanMASTER
BEDROOM
102
ENTRY HALL
100MUDROOM
101
MASTER BATH
103
102A
103A
104A
POWDER ROOM
104
101
A
SLOPE
DN
SLOPE
DN
CATHEDRAL
CEILING. PTD.
GWB FINISH
A A A
D
D
D D E F
F
DN 6"
HDWD FLOORING
51
2"
1'-7"
4'-10"
3'-3"
24'-4"
51
2"
1'-9"
2'-9"
4'-6"
51
2"
8'-1"
6'-7"
1'-6"
51
2"
5'-1"
EQ.EQ.
℄℄℄℄
6'-6"
31
2"
11'-61
2"3'-1"312"5'-512"512"2'-0"512"4'-912"512"4'-812"512"3'-2"3'-0"
31
2"
4'-91
2"
PROPOSED DECK
NEW MECHANICAL CLOSET ON
(E) BULKHEAD FOUNDATION
AND NEW FROST WALL
FRAME IN OPENING AS REQ'D
X
X
X X X X
X
X
X
XX
4
A3.0
1
A3.0
2
A3.0
3
A3.0
5
A3.0
ALIGN OPENINGS
ALIGN OPENINGS
TILE FLOORING
TILE FLOORING
TILE FLOORING
5
A3.0512"6"3'-8"DN 6"4'-0"NEW OPENING AS SHOWN
INFILL OPENING, PATCH AND
MATCH FINISHES
LINE OF (E) BREAK IN CEILING
KITCHEN
106 LIVING AREA
108
DINING AREA
107
SITTING AREA
105
BEDROOM
109
3'-0"BATHROOM
110
109A
109
B
110
A
111
A
BEDROOM
111
111B3'-7"1'-6"312"1'-712"1'-10"℄
℄
TILE FLOORING
HDWD FLOORING
HDWD FLOORING
HDWD FLOORING
HDWD FLOORING
HDWD FLOORING
HDWD FLOORING
INFILL (E) DOOR OPENING,
PATCH AND MATCH FINISHES
PROVIDE ATTIC ACCESS AS
REQ'D
(E) CABINET TO
REMAIN
NEW VANITY & FIXTURES
(E) GAS METER
BENCH
NEW OUTDOOR SHOWER
ENCLOSURE AS SHOWN
SHELFREPLACE FIXTURES IN KIND,
REUSE (E) PLUMBING
8'-6"4'-6"B
DN
PROPOSED GRILL LOCATION,
PROVIDE HARD LINE GAS
HOOK-UP WITH QUICK
DISCONNECT
DNMOSAIC TILE
FLOORING
HALF WALL
NEW 60" VANITY
DN
NEW CONC. STEP
REF.
PANTRY
PEA GRAVEL OR APPROVED
EQ.
EXTERIOR DRY LAID PAVERS
PROVIDE 'STADIUM STAIRS' TO
GRADE AS REQ'D, FINAL LAYOUT
TBD UPON OWNER REVIEW
NEW EXPOSED BEAM
CATHEDRAL
CEILING.
(PTD. GWB
FINISH)
7'-6"7'-6"13'-6"±
7'-6"
7'-6"
7'-6"
7'-6"
BEADBOARD FINISH @ ALL DRY
MASTER BATH WALLS
NEW BROOM CLOSET,
MATCH FINISH OF (E)
CABINETS
MASTER
CLOSET
112 4'-634"±2'-6"2'-0"
19'-3"
51
2"
3'-3"5'-11"5'-11"3'-3"
51
2"
5'-1"
EQ.EQ.
EXISTING RESIDENCE
℄℄℄25'-012"512"EQ.11'-012"512"3'-9"5'-1"512"℄
℄312"EQ.3'-6"102
B
HDWD FLOORING
HW AHU ELECMECH.
CLOSET
1135'-1012"512"51
2"51
2"
5'-10"
6'-9"
2
G 4'-0"DN
DN
PROVIDE NEW LANDING AT
DOOR TO MECHANICAL
CLOSET AND STAIRS AS REQ'D
ADD TYP. 12" SONOTUBE @
OUTER CORNER OF LANDING
2
PROPOSED DECKING
2X FRAMING AS REQ'D, REFER TO
STRUCTURAL DWGS
STAIRS TO GRADE TO BE 3 BOARDS
DEEP (±15")
BOTTOM OF SONOTUBE TO BE 48"
BELOW MEAN GRADE
1/4" = 1'-0"1 PROPOSED FIRST FLOOR PLAN
Scale:
Title:
Sheet:
Date: Revision:
Lynch
Residence
42 Acres Avenue
W. Yarmouth, MA 02673
02.12.2020 Issue for Permit
05.20.2020 Revision 1 Set
09.23.2020 Mechanical Rev.REVISION 209.23.2020Scale:
Title:
Sheet:
Date: Revision:
As Noted
Proposed First
Floor Plan
A1.1
1" = 1'-0"2 DECK STAIR DETAIL