HomeMy WebLinkAboutEngineered Plan98�--. ` (30 FOOT RIGHT OF WAY) ASPHALT ­- DRIVEWAY TEST HOLE #1 f ELEV.= 98.50 VENT I 1 PIPE CY I k A Q M A r, CO ASPHALT PARKING OVER— EXISTING VER—EXISTING SEPTIC TANK` TO BE REMOVED 99 s 20 J EXISTING 2 BEDROOM HOUSE #9. 93.75' TEST HOLE #2 4 ELEV.= 98.50 r 81D 50' 35 W 98 1. Contractor is responsible for Digsafe notification, Verification of Utilities and protection of all' underground utilities and pipes. 2. The septic tank anq, distribution box shall be se level on 6 of 3/4 -1 1/2' stone: 3. Backfill should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during, installation by Carmen E. Shay — Environmental Services, Inc.; 5. The contractor shall install this system in accordance with Title V of the Massachusetts state code, the approved plan and Local Regulations. 6. If, during Installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or In our design installation must halt & immediate notification be made to Carmen E. Shay — Environmental Services,, Inc.. a 1 7. No vehicle or heavy machinery shall drive over the c� septic system unless noted as H-20 septic components. f` LOT #63 :12,350 Square Feet +/— I 8. Install Tuf—Tlte gas baffles or equals on all outlet tee ends. 9. All Distribution Lines shall be 4" diameter Schedule 40 NSF PVC pipes. 10. All solid piping, tees & fittings shall be 4" diameter I / ! PROJECT BENCH MARK ✓/ TOP OF FOUNDATION ELEY. 100.00 (ASSUMED) Schedule 40 NSF PVC pipes with water tight joints.: 11. Municipal Water is Connected to ALL OF The Residence and Abutting Properties. TOE- PROPERTY LINES ARE APPROXIMATE AND 1rOMPILED FROM THE SURVEY PLAN BY KELLY & SWEETSER ENGINEERS i Permit valid for REPAIR OF SEPTIC SYSTI[ ONLY, due to State and Local septic varianc sE TITLED: "CERTIFIED PLOT PLAN -9 BASS RIVER RD YARMOUTH, MA" Board of Health review and approval is reruired f OV AUGUST 20, 2010 any future additions/renovations/alteratiors tMD IS NOT INTENDED TO BE A SURVEY PLOT PLAN sewage facilities and/or structures/dwell-ng. 11 SHOULD BE USED FOR NO PURPOSE OWNER THAN; THE SEPTIC SYSTEM INSTALLATION. r ;L Yarmouth 6lealth Department APPROVED E (STING LEACH PIT TO BE PUMPED OUT AND FILLED IN PLACE OTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE FORMER GARA, SLAB ASPHALT FOUNDATION DRIVEWAY /\ Handicap Ramli RESERVE 99 AREA I .FAILED j LEACH PIT 1 93.75' \.. ` N 81D 50' 55 jr1 0 20 40 50 {, (34 FOOT RIGHT ,OF WAY)' PROPOSED SAS 4 LC -6 CHAMBERS W/1' Stone under SCALE: 1 "=20' 4' Stone on Sides & 2' Stone on Eng OM THE EXISTING CESSPOOL/LEACH PIT TO BE DISPOSED F AS PER BOARD OF HEALTH SPECIFICATIONS. halaA D ate ' .. P LOT -PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR MICHAEL 8c DENISE O'LEARY AT 9 BASS RIVER ROAD L od o PARCEL ID: 70/101; APR 2 9' 2020 n'taa,YARMOUTH M A HEALTH DEPT. SPARED BY: All RNEW E. SHA Y ENVIRONMENTAL SERVICES t . c, $-I P.O. Box 1576 MASHPEE, MA 02649 TEL/FAX : 508--294--7498` SCALE: 1 "=20' DRAWN. BY: CES DATE: MARCH 1.9, 2020 PROJECT#9 Bass River FILENAME: 9 BassRiver.DVVG SHEET 1 OF 2 VENT PIPE�® Least 10' min. from *NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. Schedule 4 PVC w, EXISTING Foundation [house to septic tank N Septic tank covers must be D—BOX ower must must have riser and be within 8 in. of finished grade within 6 In. of finished grade ' Grade over Septic Tank — 99.00 Grade over D—Box •- 98.50 1 I S . 0.02 3 HOLE H-10' Swp,OP DIST. BOX L'. , ON O 20' al Odor Filter cover must be 6" of GRADE SAS TO BE COVERED WITH FILTER FABRIG �J SECTION A —A PROFILE VIEW OF .LEACHING SYSTEM over SAS - 98.50 TOP OF SAS —195.715 EXIST 1000 GA FROM FFOUNDATION ti 70' SEPTIC TANK u7 ,-.-r A H-10 1b' ra a 4 l 1' 4 on r' Sib" w a, on CONCRETE. FULL FouNDAnO y. 11 II N v -Sa ; II 0 o, i �r l _ SYSTEM PROFILE' d -Sa A i _� S' P 11VIDED Not to Scale- � c. i 4 `-+--8 �^�• 4'0� NOTE: ALL COMPONENTS MUST HAVE RISERS TO WITHIN 8" BELOW GRADE compacted stone. Effective width � Bottom of Test Hole 1 Elev.- 87.50 2-18" DIAM. ACCESS 5' -7" H STEEL REINFORCED PRECAST CONCRETE PLAN VIEW 3-24" REMOVABLE COVERS !j 1 THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT SET DEEPER THAN 6 INCHES BELOW FINISHED GRADE SHALL BE RAISED TO 1t1THIN S" OF FINISHED GRADE. INSTALL TUF-TiTE GAS BAFFLES OR EQUALS Garbage Grinder: No Leaching Capacity Proposed: 440 Gal./Doy Minimum Septic Tank : - 2 x 440 Gal./Day - 880 USE EXIST 1,000 GAL. Septic Tank. SOIL ABSORPTION AREA: Using percolation rate of t2 min./inch Bottom Area: 0.74 gal/day/sq. ft.x 407 sq, ft. 301,18 gallons/day Sidewall Area: 0.74 gal./day/sq, ft. x 192 sq. ft. 142.08 gallon/day Providing:, =443.26 gallons/day Use: (5) LC -6 H•-20 CONCRETE CHAMBERS, HAVING A 1' EFFECTIVE DEPTH,. (3' W x B' L) TO BE USED WITH 4' OF WASHED STONE ON THE SIDES AND 3.5' OF WASHED STONE ON THE ENDS AND 1 FOOT OF STONE UNDER ENTIRE SAS PERCOLATION TEST Date of Percolation Test: j FEBRUARY 11, 2020 Test Performed By: CARMEN E. SHAY, R.S., C.S.E.. Results Witnessed By. MALLORY LANGLER (YARMOUTH BOH) EXCAVATOR: CARMEN SHAY 1 Percolation Rate: LESS THAN 2 MPI 0 30" Test Hole No. 1 DEPTH SOILS ELEV. 0 98.50 3"min. clearance mineL-min. inlet to outlet Sandy Loam :• 13" -INLET i '• ' LOAMY TM 9" min• LiqufdTevel-" Sand OUTLET 6"'- 30" BW 10 YR 8/6 96.00 6"-- 30" Med 96.00 '4P h 2.3 Y 7/4 30"-132" G -;Ta 30"-132" tw 87.50 Eq r. 4'-0" min. Liquid depth CROSS SECTION. END --SECTION; TYPICAL 1000. GALLON. SEPTIC_ TANK` Garbage Grinder: No Leaching Capacity Proposed: 440 Gal./Doy Minimum Septic Tank : - 2 x 440 Gal./Day - 880 USE EXIST 1,000 GAL. Septic Tank. SOIL ABSORPTION AREA: Using percolation rate of t2 min./inch Bottom Area: 0.74 gal/day/sq. ft.x 407 sq, ft. 301,18 gallons/day Sidewall Area: 0.74 gal./day/sq, ft. x 192 sq. ft. 142.08 gallon/day Providing:, =443.26 gallons/day Use: (5) LC -6 H•-20 CONCRETE CHAMBERS, HAVING A 1' EFFECTIVE DEPTH,. (3' W x B' L) TO BE USED WITH 4' OF WASHED STONE ON THE SIDES AND 3.5' OF WASHED STONE ON THE ENDS AND 1 FOOT OF STONE UNDER ENTIRE SAS PERCOLATION TEST Date of Percolation Test: j FEBRUARY 11, 2020 Test Performed By: CARMEN E. SHAY, R.S., C.S.E.. Results Witnessed By. MALLORY LANGLER (YARMOUTH BOH) EXCAVATOR: CARMEN SHAY 1 Percolation Rate: LESS THAN 2 MPI 0 30" Test Hole No. 1 DEPTH SOILS ELEV. 0 98.50 Sandy Loam 0"- 6" 10 YR 3/2 Ap 98.00 LOAMY Sand 6"'- 30" BW 10 YR 8/6 96.00 6"-- 30" Med 96.00 Sand 2.3 Y 7/4 30"-132" G 87.50 30"-132" tw 87.50 Test Hole N o. 2 DEPTH SOILS ELEV. 0 98.50 Sandy Loam 0"- 6" 10 YR 3%2 Ap 98. 00 LOAMY Sand 6"-- 30" 10 YBR 5/6 96.00 Med Sand 2.5 Y 7/4 30"-132" tw 87.50 Perc #1` Depth to Perc 30'( to 48" Perc Rate= LESS THAN 2 MPI; Groundwater Not Observed No observed ESHW7` 0 120" ADJUSTED H2O Elev = None 0 132." l I I 'I —a/s" �a � rp • san.a a,wka swn. � .p r/a• - r/s• Ma.Ma awaece+�. Iwithin Oi•! cover must o \� � within 6 in. of finished grade S Units 6 ' ■ 30' W 3.5 r Effective Length SOIL ABS❑RPTI❑N SYSTEM (SAS) LC -6 H-20,LEACHING UNITS / WIGGINS PRECAST Not to Scale ?. ("' 12" -"'I /- CONCRETE COVER' 3 — 8" OUTLET KNOCKOUTS I 12' INLET ----15 5• 4• SCH. 40 Tee-/ f ` i 71 4 PLAN SECTION CROSS—SECTION 3 HOLE H--10 DISTRIBUTION ' BQX LOT PPLAN OF ROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR. MICHAEL. & DENISE O'LEARY AT 9 BASS RIVER ROAD PARCEL ID: 70/101 ¢tlyA YARMOUTH, MA PREPARED BY ' SHAY EYVVIRON. M1VTAL SER VICE'S P.O. Box 1576 a>viTr�� MASHPEE, MA 02649 TEL/FAX : 508--294--7498, SCALE: 1 "=20' DRAWN BY: CES DATE: MARCH 19 2020 PROJECT#9 Bass River FILENAME: 9 BassRiver.DWG SHEET 2 OF 2