A-303-1 - WALL SECTIONS_111120 update
FIRST FLOOR 0' -0" SECOND FLOOR 10' -0" ATTIC 20' -0" 12 10 ROOF TRUSS SEE STRUCTURAL, REINFORCE AS REQUIRED TYPICAL ROOF ASSEMBLY: • ASPHALT SHINGLE ROOFING OVER ROOFING FELT • ADHERED ICE & WATER SHIELD AT ROOF EDGES AND INTERSECTIONS; SEE ROOF PLANS • 5/8" PLYWOOD SHEATHING ON WOOD TRUSS FRAMING, SEE STRUCTURAL 1 1/2"ROXUL INSULATION BOARD, ON 2x FRAMING, FRICTION FIT BETW/COPE TO ROOF STRUCTURE 9' - 2 1/2"FINISH CEILING FINISH CEILING BATT INSULATION TO MEET R-49 LINTEL SEE STRUCTURAL WINDOW, SEE SCHEDULE STOOL AND APRON, SEE SCHEDULE PLATE, SEE STRUCTURAL EXTERIOR WALL ASSEMBLY: • RAINSCREEN SIDING ASSEMBLY - FIBER CEMENT SIDING ON ON 3" x 3/4" PT. PLYWOOD FURRING 16" O.C. • 1 1/2" INSULATED ZIP WALL SHEATHING, • FIBERGLASS BATT INSULATION IN 2x6 WALLS • MEMBRANE VAPOR BARRIER • 5/8" GYPSUM BOARD PORCH ROOF ASSEMBLY: • ASPHALT SHINGLE ROOFING OVER ROOFING FELT • ADHERED ICE & WATER SHIELD AT ROOF EDGES AND INTERSECTIONS; SEE ROOF PLANS • PLYWOOD SHEATHING ON WOOD TRUSS FRAMING, SEE STRUCTURAL FRAMING, SEE STRUCTURAL CEILING ASSEMBLY PORCH RAFTERS, SEE STRUCTURAL ROOF TRUSS, SEE STRUCTURAL FIBER CEMENT SOFFIT ON 1X WD FURRING FIBER CEMENT VENTED SOFFIT ON 1X WD FURRING; TYP METAL FLASHING SHED ROOF OVERFRAME PORCH GABLE ROOF BATT INSULATION 1X FIBER CEMENT TRIM OVER HEADER/OVERHANG FRAMING EXTERIOR WALL ASSEMBLY, SEE NOTE ABOVE PORCH SLAB, SEE STRUCTURAL COLUMN ENCLOSURE - SEE DET 1/A-306 PT. FRAMED PEDESTAL WITH BUILT UP FIBER CEMENT SURROUND WD POST SEE STRUCTURAL ALUM STOREFRONT DOOR & SIDE LIGHT, SEE SCHEDULE CEILING ASSEMBLY HEADER; SEE STRUCT FINISH FLOORING, SEE SCHEDULE FLOOR ASSEMBLY SEE DETAILS ALUM STOREFRONT DOOR & SIDE LIGHT, SEE SCHEDULE FINISH FLOORING, SEE SCHEDULE CONRETE SLAB ON VAPOR BARRIER OVER RIGID INSULATION, SEE STRUCTURAL FOUNDATION WALL, SEE STRUCTURAL FOUNDATION WALL FOOTING, SEE STRUCTURAL FOUNDATION AT COLUMN BEYOND, SEE STRUCTURAL FLASHING AT DOOR HEAD CASING CEILING ASSEMBLY VESTIBULE WALL CONSTRUCTION SEE PARTITION SCHEDULE FRAMING, SEE STRUCTURAL RAKE CONSTRUCTION FIBER CEMENT TRIM AT RAKE METAL FLASHING WITH DRIP EDGE LINE OF SHED ROOF FRAMING BEYOND, SEE STRUCTURAL FIBER CEMENT TRIM + SOFFIT FIBER CEMENT SIDING, ON 3/4" PT. FURRING, OVER PLYWOOD SHEATHING FIBER CEMENT SOFFIT ON 1X PT FURRING FLASHING AT PEDESTAL 5/4 FIBER CEMENT TRIM FRAMES GABLE A-304 2 COMPRESSIBLE FILLER BETW EDGE OF FLOOR & PORCH SLAB; TYP, COORD CIVIL & STRUCT P.LAM COUNTER & BACKSPLASH WALL MTD MAIL BOX UNIT VESTIBULE CORRIDOR 2" CLOSED CELL PLASTIC INSULATION; TYP at FOUND WALL (2' DOWN) & SLAB ON GRADE (4' HORIZONTALLY) 1 1/2" ZIP SHEATHING OVER FRAMING FIRST FLOOR 0' -0" SECOND FLOOR 10' -0" EAVE 19' -0" ATTIC 20' -0"PROPERTY LINEOVERHANG PROJECTION 2' - 0" MAX 6' - 7" HEADER; SEE STRUCTURAL EXTERIOR WALL ASSEMBLY, SEE NOTE ABOVE FLASHING AT DOOR HEAD CASING LINE OF SHED ROOF FRAMING BEYOND, SEE STRUCTURAL CEILING FRAMING, SEE STRUCTURAL FACE OF ENTRY OVERHANG FASCIA FOUNDATION AT ENTRUY OVERHANG POSTS; SEE STRUCTURAL ANY REPRODUCTION, POSSESSION OR USE OF THIS DRAWING WITHOUT THE WRITTEN PERMISSION OF WINSLOW ARCHITECTS INC. IS PROHIBITED. VIOLATORS WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW. ©2020 WINSLOW ARCHITECTS, INC. Owner/Developer: 17-533 Project number: Date issued: 89 MASSACHUSETTS AVE. ARLINGTON, MA 02474 P: 781 648.6600 F: 781 648.6601 www.winslowarchitects.com Revisions: Project: Drawing: Sheet: Stamp: Consultant: RESIDENCES AT YARMOUTH GARDENS 497 Rte. 28 West Yarmouth, MA 11/11/2020 10:39:25 AMA-303.1 WALL SECTIONS 07/23/20 COMMONWEALTH COMMUNITY DEVELOPERS. LLC DEMOLITION PERMIT 3/4" = 1'-0"A-303.1 1 BUILDING 1 FRONT ENTRY SECTION No. Description Date 1 PERMIT SET UPDATE 11/11/20 3/4" = 1'-0"A-303.1 2 BUILDING 2 FRONT ENTRY SECTION SEE TYPICAL NOTES ON ENTRY SECTION 1/A-301.1